Page 2 - Congratulations; Listing Label Information/Location; Homeowner Reference Information; Minimum Clearances To Combustible Material; SA
Page 2 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Read this manual before installing or operating this appliance. Please retain this owner’s manual for future references. Congratulations Congratulations on selecting a Heatilator wood burning fireplace. The Heatilator fireplace you have...
Page 3 - Heatilator • Constitution EPA Fireplace • 480-1091H; Table of Contents; Warranty
Model: C ONSTITUTION E PA C ERTIFIED F IREPLACE Serial No / Numéro De Série OMNI-Test Laboratories, Inc. Report #061-S-40-2 LISTED FIREPLACE, SOLID FUEL TYPE, ALSO SUITABLE FOR MANUFACTURED HOME INSTALLATION. (UM) 84 HUD. "For Use with Solid Wood Fuel Only." I nstall and use only in accordan...
Page 4 - LIMITED LIFETIME WARRANTY
Page 4 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 4021-645C 12-29-10 Page 1 of 2 Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and...
Page 5 - This warranty is void if:
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 5 4021-645C 12-29-10 Page 2 of 2 WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites...
Page 6 - Listing and Code Approvals; A. Appliance Certification; DO NOT INsTAll IN slEEpING ROOm; B. Manufactured Home Approved
Page 6 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 1 Listing and Code Approvals A. Appliance Certification This appliance is approved for manufactured home instal- lations when not installed in a sleeping room and when an outside combustion air inlet is provided. THE STRUC- TURAL INTEGR...
Page 7 - G. Glass Specifications; NOTICE: This installation must conform with local codes. In the; NOTICE: This appliance must be electrically wired; F. Electrical Codes
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 7 G. Glass Specifications NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the UL127, (UM) 84-HUD and NFPA211 in the U.S.A. and the ULC 610-M87 and CAN/CSA-B365 Installation Codes...
Page 8 - User Guide; Operating Instructions; Hot glass will cause burns.; Glass and other surfaces are hot during operation AND cool down.; according to operating instructions could cause fi re or injury.
Page 8 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 User Guide 2 Operating Instructions WARNING Hot glass will cause burns. • DO NOT touch glass until it is cooled • NEVER allow children to touch glass • Keep children away • CAREFULLY SUPERVISE children in same room as fi replace. • Aler...
Page 9 - B. General Information; CORRECT POSITION; Ceramic Blanket; INCORRECT POSITIONS; D. Firebrick Placement
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 9 WARNING! Risk of Fire! Keep combustible materials, gasoline and other flammable vapors and liquids clear of the fireplace.DO NOT: • store flammable materials close to the fireplace • use gasoline, lantern fuel, kerosene, charcoal lighte...
Page 10 - Hardwood vs. Softwood
Page 10 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 WARNING! Risk of Fire!• DO NOT bURN WET OR GREEN WOOD. • WET, UNsEAsONED WOOD CAN CAUsE ACCUmUlATION OF CREOsOTE. Soft woods Hard woods • Douglas Fir • Oak • Pine • Maple • Spruce • Apple • Cedar • Birch • Poplar • Aspen • Alder E. Woo...
Page 11 - Seasoned Wood; NOTICE: Seasoning time may vary depending on drying; Storing Wood; Outside air control handle may be warm. Adjust before
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 11 Seasoned Wood • Cut logs to size • Split to 6 in. (152 mm) or less • Air dry to a moisture content of around 20% - Soft wood - about nine months - Hard wood - about eighteen months NOTICE: Seasoning time may vary depending on drying co...
Page 12 - WARNING! Risk of Fire and smoke! Fireplaces; Medium or Medium High Burn Setting:; G. Clear Space Near the Fireplace; WARNING! Risk of Fire! DO NOT install and or use; ride Switch in manual postition
Page 12 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Outside Air Control Handle Figure 2.4 General Outside Air operating parts Combustible materials must not be stored on the hearth ex- tension. Room furnishings such as drapes, curtains, chairs or other combustibles must be at least 4 ft...
Page 13 - What To Do if Your Stove is Over-Firing
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 13 To provide reasonable fire safety, the following should be given serious consideration: 1. Install at least one smoke detector on each floor of your home to ensure your safety. They should be located away from the heating appliance and...
Page 14 - Kindling or 1st stage:; Also refer to care
Page 14 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 NOTICE: Fireplace should be run full open for a minimum of 30 minutes a day during heating season to keep air pas- sages clean. WARNING! Risk of Fire! Keep combustible materials, gasoline and other flammable vapors and liquids clear of...
Page 15 - burn time, setting the ACC may not be required. Burn Dry,; ACC OVERRIDE
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 15 Final stage: The final stage of burning is the charcoal stage. This occurs when the flammable gases have been mostly burned and only charcoal remains. This is a naturally clean portion of the burn. The coals burn with hot blue flames. ...
Page 16 - Q. Burning Guidelines; For maximum operating efficiency with the lowest; *Combustion Air Control; *These are approximate settings, and will vary with type of; P. Manual Timer Override; If timer is unintentionally engaged, push the Timer Over-
Page 16 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Q. Burning Guidelines For maximum operating efficiency with the lowest emissions, follow these operating procedures: 1. Regardless of desired heat output, when loading the fireplace, burn your fireplace with the Combustion Air Control ...
Page 17 - Troubleshooting; A. Understanding Vent Problems
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 17 3 Troubleshooting This fireplace will operate correctly only if adequate ventila- tion is provided to allow proper draft to the fireplace system. Hearth & Home Technologies assumes no responsibility for the improper performance of ...
Page 18 - Strong
Page 18 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Another appliance in home also exhausting air (furnace, fan, dryer, etc.)? Air register from furnace near fireplace? Doors opening and closing? Window closed for start-up? Outside air closed? Overhead fan operating? Overhanging tree? B...
Page 19 - C. Diagnostics and Problem Solving; I smell smoke in the house during operation. What is causing it?
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 19 C. Diagnostics and Problem Solving Diagnostic Question Possible Causes of Condition Solutions Are the air controls open? • No draft • No combustion air Open air controls Is there enough paper? Insufficient heat to ignite kindling Use m...
Page 21 - A. General Maintenance; Maintenance and Servicing the Fireplace; Formation and Need For Removal
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 21 A. General Maintenance 1. Creosote (Chimney) Cleaning • By: Homeowner / Chimney Sweep • Task: See the following instructions. Remove all ash from the firebox and extinguish all hot embers before disposal. Allow the appliance to cool co...
Page 22 - Care and Cleaning of Plated Surfaces; Disposal of Ashes; WARNING! Fire Risk! Do not use chimney cleaners or flame; Glass Cleaning
Page 22 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Clean-plated surfaces with vinegar or a glass cleaner before lighting your first fire to prevent permanent staining. CAUTION • Do not use polishes with abrasives. It will scratch plated surfaces. CAUTION Clean all the fingerprints and ...
Page 23 - Maintenance Task List; HINT; NOTICE: REMOvE ALL LABELS FROM gLASS BEFORE
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 23 Inspect Maintenance Tasks Screens 1. Assess condition of screen and replace as necessary. 2. Verify maintenance of proper clearance to combustible household objects. Glass Doors 1. Inspect glass panels for cracks. Replace if this condi...
Page 24 - Brick Size; Firebrick Replacement
Page 24 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 The firebox of your fireplace is lined with high quality firebrick, which has exceptional insulating properties. There is no need to use a grate; simply build a fire on the firebox floor. Do not operate the fireplace without bricks. IM...
Page 25 - Baffle Removal and Installation; NOTICE; Fan Replacement; Fan Cord Location
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 25 3. Baffle Removal and Installation 1. Remove all ash from firebox, and extinguish all hot embers before disposal into a metal container. 2. Remove the baffle protection channel by turning it down and pulling it out of the firebox. See ...
Page 26 - Fan Replacement Instructions
Page 26 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Unplug wire harness before removing fan Remove nut and lift out fan Figure 4.9 Fan Motor Fan Replacement Instructions 1. Remove the brick from the bottom of the fireplace and 3 of the back vertical bricks. 2. Remove the 2 screws from t...
Page 27 - Timer Assembly Replacement; Remove 2 screws & pry open door; Disconnect power by turning off circuit breaker BEFORE
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 27 5. Timer Assembly Replacement 1. Remove both doors by lifting doors up and off of hinges. 2. Remove the black knob and spring handle.3. Remove the outside air knob and then the 4 screws from each corner of fascia and remove the fascia....
Page 28 - Remove Timer
Page 28 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Linkage Arm Slider Control Rod Linkage Arm Slider Control Rod Remove 2 bolts from timer assembly Timer Assembly with Gasket Figure 4.16 Figure 4.17 Figure 4.18 Figure 4.20 1 . Loosen set screw on timer, remove 2 screws and remove timer...
Page 29 - D cut side of timer shaft must face; Place linkage control arm over timer shaft and tighten; Tighten set screw; Rotate linkage control arm into final position and re-
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 29 D cut side of timer shaft must face away from the Linkage Timer Arm 3. Place linkage control arm over timer shaft and tighten set screw. Figure 4.22. Tighten set screw Figure 4.22 1 2 3 4 5 3 4 5 6 7 8 9 10 Figure 4.23 Exploded View of...
Page 30 - Date of Service
Page 30 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Date of Service Performed By Description of Service C. Service & Maintenance Log
Page 31 - Installer Guide; Getting Started; A. Typical Fireplace System
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 31 Installer Guide 5 Getting Started A. Typical Fireplace System Figure 5.1 Typical Fireplace System Termination Cap Chimney penetrates roof preferably without affecting roof rafters Offset/Return (with hanger straps) Attic insulation shi...
Page 32 - B. Design and Installation Considerations; NOTICE: Check building codes prior to installation.; D. Negative Pressure; WARNING! Risk of Asphyxiation! Negative pressure
Page 32 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 B. Design and Installation Considerations NOTICE: Check building codes prior to installation. • Installation MUST comply with local, regional, state and national codes and regulations. • Consult insurance carrier, local building inspec...
Page 34 - parts could impair safe operation.; • Read all the instructions before starting the; G. Fireplace System Requirements
Page 34 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 F. Tools and Supplies Needed Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw Framing material Pliers Non-combustible sealant Hammer Gloves Phillips screwdriver Framin...
Page 35 - Framing & Clearances; Constitution; NOTICE: In addition to these framing dimensions, also; A. Selecting Fireplace Locations
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 35 6 Framing & Clearances Several options are available to you when choosing a loca- tion for your fireplace. This fireplace may be used as a room divider, installed along a wall, across a corner or used in an exterior chase. See Figu...
Page 37 - Wiring for fans must be done before framed; base of the fireplace; C. Frame the Fireplace
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 37 Figure 6.3 Framing the Fireplace WITHIN ENCLOSURE AREA: Appliance to backwall 1 in. (25 mm) Appliance to sidewall 1 in. (25 mm) Duct boots to framing 0 in. (0 mm) Top standoffs to header 0 in. (0 mm) Door opening to sidewall 22-7/8 in....
Page 38 - WARNING; Comply with all minimum clearances specified.; D. Electrical Access and Wiring Diagram; NOTICE: Wiring for fans must be done before framed; Standard wall mount with; Incoming Power
Page 38 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Do not apply combustible finishing materials over any part of the front of this fireplace. • The metal fireplace face may only be covered with noncombustible materials such as ceramic tile, brick, or stone. • Do not cover or block any ...
Page 39 - Installation of Fireplace; tion; A. Install the Outside Air Kit; ing cavity, or enclosed spaces such as an attic or garage.
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 39 7 Installation of Fireplace This fireplace will operate correctly only if adequate ven- tilation is provided to allow proper draft to the fireplace system. See Section 6.An outside air kit must be used for combustion to mini- mize the ...
Page 40 - Figure 7.3 Outside Combustion Air Handle Location
Page 40 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Attic insulation shield must be used to keep insulation away from chimney. Ceiling firestop on floor of attic. 3 ft min. from top of uppermost chimney section to air inlet. Fiqure 7.2 Outside Air Inlet Locations Termination Cap supplie...
Page 41 - • Position the Fireplace; DO NOT install against vapor barriers or exposed; B. Secure the Fireplace
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 41 • Position the Fireplace This fireplace may be placed on either a combustible or noncombustible continuous flat surface. Follow the in- structions for framing in Section 6.C. Slide the fireplace into position. Be sure to provide the mi...
Page 42 - Chimney Assembly
Page 42 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Chimney must extend beyond combustible roof structure Maintain minimum height of chimney above roof Additional support for tall chimneys Install roof flashing according to minimum requirements Maintain minimum clearances to combustible...
Page 43 - NOTICE: A maximum of two pairs of offsets and returns; NOTICE: You must provide support for the pipe during; A. Chimney Requirements
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 43 Vertical distances are measured from the base of the fire- place as shown in Figure 8.2 To determine the chimney components needed to complete your particular installation, follow the steps below:• Determine the total vertical height o...
Page 44 - • Use an offset/return to bypass overhead obstructions.
Page 44 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Table 8.2 15-degree SL306 SL312 SL318 SL324 SL336 SL348 30-degree A Offset B Height A Offset B Height in. mm in. mm in. mm in. mm 1-5/8 41 13-3/8 340 - - - - - - 3-5/8 92 15-1/2 394 2-7/8 73 17-3/4 451 1 - - - - - 5-1/2 140 18-5/8 473 ...
Page 45 - NOTICE: Chimney Air Kit, Part CAK4A is REqUIRED when; NOTICE: Chimney sections cannot be disassembled once; D. Assemble the Chimney Sections
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 45 Figure 8.4 Assembling Chimney Sections Attach Flue First CAK4A Secure with Screws Provided Push Together Secure to Top NOTICE: Chimney Air Kit, Part CAK4A is REqUIRED when using the SL-300 Pipe Series. Detailed instructions are supplie...
Page 46 - CAUTION! Risk of Fire! Ceiling firestops must be used; F. Install Ceiling Firestops
Page 46 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 ROOM ABOVE (non-insulated ceiling) ATTIC ABOVE (insulated ceiling) B A Ceilng firestop attached to bottom of framing Ceiling firestop attached to top of framing When attic insulation shield not used Note: Use same dimensional lumber fo...
Page 47 - WARNING! Risk of Fire! Use of cardboard or other; overlap; DO NOT pack insulation between the chimney and the; G. Install Attic Insulation Shield
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 47 Installation of a ceiling firestop is required• Refer to Figures 8.8 - 8.10.• Roll the shield (around the chimney if already installed) until you have a 3 in. (76 mm) overlap and the three holes on each side match up (large holes on to...
Page 48 - The following steps should be skipped if using a; Uniform Building Code; J. Cut out Hole in Roof; NOTICE: Roofing shingles must be below the flashing
Page 48 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 WARNING! Risk of Fire! You MUST maintain 2 in. (51 mm) air space to insulation and other combustible materials around the chimney system. Failure to do so could cause overheating and fire. The following steps should be skipped if using...
Page 49 - M. Chimney Termination Requirements
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 49 • Install a cap approved and listed for this fireplace system. • Locate cap where it will not become plugged by snow or other materials. • Locate cap away from trees or other structures. • The bottom of the termination cap must be at l...
Page 50 - Consult local codes for framing details.
Page 50 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 NAIL FLASHING PLATE CHIMNEY THIMBLE EXTENSION SCREW FLASHING THIMBLE ADJUSTABLE EXTENSION HOLES FLASHING CHIMNEY FLASHING PLATE NAIL THIMBLE SCREW THIMBLE EXTENSION N. SL-300 Series Ceiling/Roof Thimble 1. Locate the point where the ch...
Page 51 - Chase Installations; WARNING! You must install false ceilings and ceiling; A. Construct the Chase
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 51 A chase is a vertical boxlike structure built to enclose the fireplace and/or its vent system. Vertical chimneys that run on the outside of a building must be installed inside a chase.In cold climates, it is recommended that the chase ...
Page 52 - WARNING! Risk of Fire! DO NOT caulk the pipe to the; WARNING! Risk of Fire! The minimum overlap of cap; D. Install Termination Cap
Page 52 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Install as per Sections 7 and 8. • You MUST use a chase top in a chase installation. Chase tops are available from your Heatilator dealer or may be field constructed. • Include a turndown and drip edge to prevent water from seeping int...
Page 53 - TCT375 Terra Cotta Cap
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 53 • ST375 Square Termination Cap Chimney Pipe Chase Top Termination Cap Chase Collar 2 in. (51 mm) Minimum Height Place waterproof caulk or sealer under each flange of the termination cap and on top of each screw to help prevent leaks. F...
Page 54 - Finishing; ASTM E 136, Standard; B. Combustible Materials; Follow these instructions exactly.
Page 54 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 10 Finishing • Materials which will not ignite and burn, composed of any combination of the following: - Steel - Iron - Brick - Tile - Concrete - Slate - Glass - Plasters • Materials reported as passing ASTM E 136, Standard Test Method...
Page 55 - Complete installation; • Non-Combustible Sealant Material; D. Hearth Extension
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 55 1in. (25mm) OVERLAP Metal strips 2 in. (51mm) under edge of Fireplace and Hearth Extension and 2 in. (51mm) on both side of fireplace opening. Nail or screw metal strips in place. Seal with non-combustible sealant Figure 10.1 Figure 10...
Page 56 - Fireplace and Hearth Extension are flush on the; Raised Hearth Extension Framing; Position the Hearth Extension
Page 56 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 2. Fireplace and Hearth Extension are flush on the floor: Non-combustible flooring 20 in. (508mm) in front of and 8 in. (203mm) to either side of the fuel opening with a minimum thickness of 1 in. (25mm) and (“k” value = 0.49). See Fig...
Page 57 - E. Finishing Material; • Combustible Material
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 57 3. Fireplace is installed flush on the floor and Hearth Extension is raised to the bottom of the fascia: Raised hearth must be constructed of non-combustible materials such as cement block or equivalent material. Non- combustible floor...
Page 58 - surfaces; Refer to page 37 for clearance requirements
Page 58 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 60 in. (1524mm) Mantel Clearances are from bottom of appliance to lower edge of mantel or trim Trim 48 in. (1219mm) A combustible mantel may be positioned no lower than 60 in. (1524mm) from the base of the fireplace.The combustible man...
Page 59 - Caution! ALL wiring should be done by a qualified electrician and; Possible Air Duct Runs / Locations; Accessories
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 59 A. Heat Zone Kit (Optional) This kit is tested and safe when installed in accordance with this installation manual. It is your responsibility to read all instructions before starting installation and to follow these instructions carefu...
Page 60 - INSTALLATION; Run Length; cover the raw insulation to prevent it tfrom blow-; elbows is recommended.; of the fireplace assembly.
Page 60 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 INSTALLATION 1. Remove the knockout or cover plate from the top of the fireplace and discard it. See Figure 11.2. 2. Cut a 3 in. (76mm) hole in the insulation board as per the dimensions shown in Figure 11.2 Adapter Mounting Plate Star...
Page 61 - NOTICE: DO NOT UsE ADJUsTAblE REGIsTERs.
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 61 NOTICE: Secure the duct so that clearance to the fireplace outer wrap is maintained. Tape all seams with aluminum tape 1-1/4 in. (32mm) minimum width or as specified by local codes.) 9. Seal all the way around the inside of the Return ...
Page 63 - Reference Materials; A. Fireplace Dimensions; Fan Electrical Access
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 63 12 Reference Materials A. Fireplace Dimensions L K A B C D E F TOP VIEW FRONT VIEW SIDE VIEW Constitution A B C D E F in 3-1/2 31-1/8 40 37 40-5/16 43-13/16 mm 89 791 1016 940 1024 1100 G H I J K L in. 6-1/2 9-11/16 5-7/8 1 23-1/8 11-1...
Page 64 - B. Chimney Components; B = Effective length (length of chimney part; Catalog
Page 64 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 B. Chimney Components RF370 - Roof Flashing Flat to 6/12 Pitch 12 in. (305 mm) 24-5/8 in. (625 mm) 27-3/8 in. (695 mm) RF371 - Roof Flashing 6/12 to 12/12 Pitch 12in. (305 mm) 31 in. (787 mm) 24-5/8 in. (625 mm) Firestop Spacer A B 14-...
Page 67 - Constitution Woodburning Fireplace; Part number list on following page.; Beginning Manufacturing Date: June 2003
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 67 C. Service Parts C40 Constitution Woodburning Fireplace Part number list on following page. 2 1 3 4 7 8 9 10 11 6 13 5 12 14 15 Beginning Manufacturing Date: June 2003 Ending Manufacturing Date: Active
Page 68 - ITEM
Page 68 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 C40 Service Parts IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized de...
Page 69 - Side view; Baffle Protection Channel
4/12 Heatilator • Constitution EPA Fireplace • 480-1091H Page 69 C40 Service Parts IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized de...
Page 70 - This page intentionally left blank.
Page 70 Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 This page intentionally left blank.
Page 71 - D. Contact Information; For the location of your nearest Heatilator dealer,; DO NOT DISCARD THIS MANUAL; CAUTION
Heatilator • Constitution EPA Fireplace • 480-1091H 4/12 Page 71 D. Contact Information Heatilator, a brand of Hearth & Home Technologies Inc. 1915 W. Saunders St. Mt. Pleasant, IA 52641 www.heatilator.com Please contact your Heatilator dealer with any questions or concerns. For the location of ...