Page 2 - 52 Mountain House Road; sa
2 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove CAUTION: HOT WHILE IN OPERATION- DO NOT TOUCH- KEEP CHILDREN AND CLOTHING AWAY- CONTACT MAY CAUSE SKIN BURNS- SEE NAMEPLATE AND INSTRUCTIONS. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS A CONSIDERABLE DISTANCE ...
Page 3 - TaBLE Of CONTENTs
3 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove TaBLE Of CONTENTs section 1: Listing and Code approvals A. Appliance Certifications 4 B. Mobile Home Approval 4 C. Glass Specifications 4 D. Electrical Rating 4 E. BTU & Efficiency Specifications 4 section 2: sp...
Page 4 - Listing and Code approvals; a. appliance Certification; This appliance is also approved for installation in; B. Mobile Home approved; us only; C. glass specifications
4 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove 1 Listing and Code approvals a. appliance Certification Model: TL2.0 Woodburning Stove Laboratory: OMNI-Test Laboratories, Inc. Report No. 135-S-29-2 Type: Solid Fuel Room Heater / Wood Burning Type. Standard(s): UL...
Page 5 - CO fumes are toxic and can be fatal.; special Warnings and Notes
5 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove NEvER CONNECT THIs uNIT TO a CHIMNEy fLuE sERvINg aNOTHER aPPLIaNCE. Installation and repair of this stove should be done by a qualified service person. We recommend that the stove be inspected before use and at lea...
Page 6 - getting started; CauTION; NOTE: Clearances may only; WaRNINg; Considerations; appliance Location
6 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove 3 getting started CauTION • dO NOT CONNECT THIs uNIT TO a CHIMNEy fLuE sERvICINg aNOTHER aPPLIaNCE. • dO NOT CONNECT TO aNy fORCEd aIR dIsTRIBuTION duCT OR sysTEM. B. fire safety Maintain the designated clearances t...
Page 7 - C. Component Locations
7 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove C. Component Locations Top Load Opening Air Control Front Load Door Top Load Door Bypass Damper Control Handle Ash Door Ash Door Latch Front Load Door Latch Bolt-Down Holes for Mobile Home Installations
Page 9 - dimensions & Clearances; a. appliance dimensions; Environmental Protection Agency’s
9 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove 4 dimensions & Clearances a. appliance dimensions The Harman TL2.0 meets the U.S. Environmental Protection Agency’s emission limits for wood heaters sold after July 1, 1990. Weight..................................
Page 10 - B. Clearances To Combustibles; Location; *for clearance reduction methods, refer to NfPa 211 or Local Codes; vertical venting Configuration
10 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove B. Clearances To Combustibles Location single-wall Pipe double-wall Pipe a unit to side Wall 14" / 356 mm 14" / 356 mm B unit to Back Wall 13" / 330 mm 7" / 178 mm C vent Pipe to side Wall 24" /...
Page 11 - vertical venting Configuration - Horizontal Exit
11 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove Location single-wall Pipe a unit to side Wall 13" / 330 mm B unit to Back Wall 13" / 330 mm C vent Pipe to side Wall 23" / 584 mm d vent Pipe to Back Wall 18" / 457 mm E vent Pipe to Ceiling 16"...
Page 12 - C. floor Protection Requirements; floor Protection Requirements; The; floor Protection
12 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove C. floor Protection Requirements Minimum Size floor protection (USA) is 48" Deep By 32.5" Wide. floor Protection Requirements If the appliance is being installed on a combustible floor, non-combustible floo...
Page 13 - Chimneys and venting; effect; B. Chimney Connectors; United States
13 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove 5 Chimneys and venting a. draft Draft is widely misunderstood. It is important that you, the stove operator, realize that draft is a variable effect , not a given quantity. Stoves and chimneys do not have draft, ye...
Page 14 - AN APPROVED CANADIAN
14 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove d. The Chimney This unit must be installed into a chimney approved for use with solid-fuel appliances. In the U.S., it must be connected to (1) a prefabricated chimney complying with the requirements for Type HT ch...
Page 15 - exactly
15 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove 1. Existing Masonry Chimneys If you plan on using a pre-existing masonry chimney, have it thoroughly inspected and cleaned. Any faults which make the chimney unsafe and unusable must be repaired prior to use. These...
Page 16 - standard Ceiling Installation with factory Built Chimney; Roof
16 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove Chimney Cap storm Collar Chimney sections Minimum air space with Chimney Listing Chimney Connector Chimney support standard Ceiling Installation with factory Built Chimney Roof flashing Roof Radiation shield attic ...
Page 17 - Cathedral Ceiling Installation with factory Built Chimney
17 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove Roof Flashing Chimney Cap Factory-Built Metal Chimney Sealed Storm Collar Finishing Collar Chimney Connector Roof Radiation Shield Cathedral Style Chimney Support Cathedral Ceiling Installation with factory Built C...
Page 18 - Chimney Breach fireplace Conversion with Non-Combustible Wall
18 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove Minimum Clearance to unprotected Ceil- ing 16" Chimney Connector sealed at Thimble flue Liner with Re- quired air space Three sheet Metal screws per joint of Chimney Connector Mantel and Trim Pro- tection * flo...
Page 19 - Chimney Breach Fireplace Conversion with Combustible Wall
19 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove Chimney Breach Fireplace Conversion with Combustible Wall Minimum Clearance from Chimney Connector to Un- protected Ceiling Flue Liner with Required Air Space Listed or Approved Thimble Assembly 1" Clearance fo...
Page 20 - Mobile Home; a. Mobile Home Installation; dO NOT INsTaLL IN a MOBILE HOME IN CaNada.
20 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove 6 Mobile Home a. Mobile Home Installation Mobile home approval - u.s. only. dO NOT INsTaLL IN a MOBILE HOME IN CaNada. 1. An outside air inlet must be provided for combustion air, and must remain clear of leaves, d...
Page 21 - a. Outside air attachment; kEEP TOP LOad dOOR CLOsEd ExCEPT WHEN
21 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove 7 appliance set-up a. Outside air attachment Parts and Supplies Needed: Kit #1-10-856082, 1 piece of metal flexible pipe, 4" X needed length. 1 Rodent Screen, and aluminum tape. Plus, a trim ring for finishing ...
Page 22 - d. Optional Blower Installation; E. Top air grill Option
22 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove d. Optional Blower Installation use ONLy Blower Part #1-00-856002 With This appliance. The optional blower kit installs easily to the rear of the TL2.0. First, remove the air jacket shield from the rear of the stov...
Page 23 - Operating Instructions; a. fuel specifications; B. general Operating Information; CauTION: approved for use with wood fuel only.; safETy NOTICE; Front Door
23 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove 8 Operating Instructions a. fuel specifications Select only dry, seasoned wood . Wood for burning should never be exposed to rain or extremely damp conditions. Hardwoods are favored because they are heavier and con...
Page 24 - d. The Combustion Process; The grates and andirons must remain in place; C. Burning as a fireplace
24 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove d. The Combustion Process Combustion in the firebox is precisely controlled and is best explained in two parts. During a wood fire, combustion air enters at the bottom front of the stove where it travels upward thr...
Page 25 - Minimum; f. Before your first fire; NOTE: The bypass damper must be open for
25 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove Minimum Primary Air Maximum Primary Air For low burn, slide the air control to the left. For medium burns, use notches 1 to 2. Maximum heat is attained with the air control all the way to the right. Do not burn the...
Page 27 - service & Maintenance; Creosote- formation and Need for Removal; If you experience a chimney fire; seasonal cleaning
27 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove 9 service & Maintenance a. Creosote- formation and Need for Removal; When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moisture to form creosote. The creosote vapo...
Page 28 - B. general Maintenance Procedures; CAuTion: never use AbrAsive mATeriALs
28 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove B. general Maintenance Procedures 1. ash Removal • frequency: As needed / Every day or two • By: User Wear Leather gloves To Prevent skin Burns! Open the ash removal door by lifting upward on the latch handle, then...
Page 29 - • disconnect Power Cord Before servicing.
29 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove 3. firebox • frequency: As necessary / Yearly • By: User Cleaning the firebox and internal heat exchange surfaces is recommended to maintain thermal efficiency. Depending on the quality and quantity of fuel being u...
Page 30 - Reference Materials; lo
30 Dry Seasoned Wood Only! 3-90-08560 Save These Instructions TL2.0 Woodburning stove 10 Reference Materials Var iable S p eed S wit ch Po w er C or d B lo w er Ther mosta t G rounded t o housing B lack W ir e W hit e W ir e 2 1 TL2.0 / TL2.6 Optional B lo w er K it #1-00-856002 - WIRING DIA GR AM
Page 32 - service Parts; stocked
service Parts 09/11 Beginning Manufacturing date: sept 2011 Ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an au...
Page 34 - grams Per Hour; sMoKe; Wood heaters with higher efficiencies cost less to operate.; efficiency; Heat outPut; use this to choose the right size appliance for your needs.
Manufactured by: HeartH & HoMe tecHnologies, inc. Model: tl2.0 u.s. enviroMental Protection agency Meets EPA particulate matter (smoke) control requirements for noncatalytic wood heaters built on or after July 1, 1990. 0 8.5 grams Per Hour sMoKe 50% 60% 70% 80% 90% 100% Wood heaters with higher ...
Page 35 - LIMITED LIFETIME WARRANTY
4021-645C 12-29-10 Page 1 of 2 Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT autho...
Page 37 - service & Maintenance Log
37 Save These Instructions 3-90-08560 Dry Seasoned Wood Only! TL2.0 Woodburning stove service & Maintenance Log Date Of Service Performed By Description Of Service
Page 40 - Proudly Printed On 100% Recycled Paper
Proudly Printed On 100% Recycled Paper At Harman, we build each product to a standard, not a price.This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels. (Signature of Boxer) Your premium quality hearth prod...