Congratulations, You have just purchased the finest wood / coal boiler available. Harman Trident boilers are constructed of high quality materials and are manufactured by a highly skilled team of assemblymen. Each boiler is inspected and pressure tested for quality assurance. This manual is designed...
Page 4 - Packing List; The Following items are supplied with your Harman Trident; Please notify your Harman Dealer if you are missing any items.
Packing List The Following items are supplied with your Harman Trident Boiler: Please notify your Harman Dealer if you are missing any items. -- Shaker Handle --Johnson Controls Aquastat - (3) pieces; A350 Controller w/ Sensor wire S350 Stage Module Y350 Power Supply --Immersion Well --Din Rail and ...
Page 5 - Installation; Getting Started; Caution: Boiler should not Be; Locating Boiler
Installation Getting Started The sheet metal sides and top are easily removed to reduce the chance of dents and/or scratches in the finish. Simply lift the top off, and that will allow the sides to be pulled away and up, for removal. To re-install, slide the channel, at the bottom of each side piece...
Page 6 - Aquastat Installation; Wiring Diagram
Bolt the Automatic Draft Control through the 1/2 in. hole in the center of the bottom door. Be sure to hold the Draft Control straight while tightening. Feed the two wires from the draft mo- tor through the flexible conduit and a 90˚ fitting. Secure the fitting to the draft motor and that end of the...
Page 8 - plumbing
8 3 feet (0.9m) above the point at which they exit from the roof, it must also extend 2 feet (0.6m) above the highest point within a 10 ft. (3m) radius. DO NOT CONNECT THIS uNIT TO A CHImNEy fLuE THAT IS SErVING ANOTHEr AppLIANCE. Limit connector pipe to 8 ft. or less, with no more than two elbows. ...
Page 10 - Operation; Automatic Draft Control; Never start a fire without water in the
10 Operation Automatic Draft Control The heat output is regulated by the auto- matic draft control on the bottom door. The electric motor (A) opens and closes the flapper door (B). Opening and closing the flapper door regulates the air flow into the firebox. The maximum air flow can be adjusted by t...
Page 11 - Starting a Coal fire; Loading
11 Operation Starting a Coal fire Make sure the boiler and all piping is full of water and that all air has been purged from the system. Never start a fire without water in the system. An explosion will occur. Turn on electrical power to the boiler. This should cause the automatic draft control to o...
Page 12 - Safety Tips; Chimney problems
1 Safety Tips When opening the firebox door, it should be cracked, slightly open, for a few seconds to allow air in to burn any gases which may be present. This will also allow smoke to be drawn away from the door. Whenever the ash pan door is open, it should be closed before opening the firebox doo...
Page 13 - Maintenance; maintenance
1 Maintenance maintenance The spiral chamber is basically self-cleaning. However, if there is a draft problem and you have been burning wood for a long time with little demand, the spiral chamber will need to be cleaned. To clean the spiral chamber, remove the stovepipe and scrape any creosote or de...
Page 14 - Warranty
1 Warranty 1 year Limited Warranty (commercial) 5 year Limited Warranty (residential) Warranty is not transferable. Harman Stove Company warrants its products to be free from defects in material and workmanship, in normal use and service, for five (5) years from the date of purchase. If defective in...