Page 2 - Table of ConTenTs
INTRODUCTION............................................................ 3 INSTALLATION.............................................................. 4 . Clearances.................................................................. 4 . Venting.............................................................
Page 4 - INSTALLATION; CleaRanCes
In. addition. to. these. clearances,. adequate. accessibil- ity. clearance. for. servicing. and. proper. operation. must. be. maintained. Do.not.in.any.way.obstruct.the.combustion.air.inlets. that.are.located.under.the.heater. If.this.appliance.is.installed.directly.on.carpeting,.tile. or other comb...
Page 5 - VenTInG; TesT foR flUe sPIllaGe
VenTInG Use Only Approved Venting The.Clarity.gas.heater.is.tested.and.listed.for.connection. to.a.4".(100.mm).listed.Class.B.venting.system.. If.the.unit.is.installed.to.vent.through.an.approved.masonry. chimney. or. a. factory-built. chimney. system,. an. approved. Class.B.chimney.liner.must.b...
Page 6 - asseMblY
The.front.is.released.when. levers.on.the.left.and. right.sides.are.pushed.to. the.rear asseMblY The.Clarity.is.shipped.from.the.factory.with.the.log.set. packed inside the firebox. To prepare the stove for installa - tion,.the.log.set.must.be.unpacked,.the.appropriate.burner. system.module.for.eith...
Page 8 - NATURAL GAS; PROPANE
Pipe.Length. Schedule.40.Pipe. Tubing,.Type.L (Feet). Inside.Diameter. Outside.Diameter RECOMMENDED.GAS.PIPE.DIAMETER NOTE:.NEVER.USE.PLASTIC.PIPE..CHECK.TO.CONFIRM. WHETHER.YOUR.LOCAL.CODES.ALLOW.COPPER.TUBING. OR.GALVANIZED.PIPE. N.G.. L.P.. N.G.. L.P. 0-10. 1/2". 3/8". 1/2". 3/8" ...
Page 9 - ConneCTInG THe CoRDseT
WaRnInG: THIs HeaTeR Is eqUIPPeD WITH a THRee-PRonGeD GRoUnDInG PlUG THaT sHoUlD be PlUGGeD DIReCTlY InTo a PRoP- eRlY GRoUnDeD ReCePTaCle. Do noT CUT oR ReMoVe THe GRoUnDInG PRonG fRoM THe PlUG. Terminal.strip.for. thermostat.connec- tion Rear.view.of.Clarity ConneCTInG THe CoRDseT The.Clarity.B-Ve...
Page 11 - HoW To TURn off THe fIRe; Operation; HoW To lIGHT THe fIRe
11 ..•If. the. knob. does. not. pop. up. when. released,. stop. and. immediately.call.your.service.technician.or.gas.supplier. ..•If.the.pilot.will.not.stay.lit.after.several.tries,.turn.the. gas.control.knob.to."OFF".and.call.your.service.technician. or.gas.supplier. 11.. . Turn. the. gas. ...
Page 12 - Maintenance
1 Maintenance A qualified service person recommended by your Harman.dealer.should.conduct.an.annual.inspection.and. maintenance.of.your.Clarity,.its.venting,.and.the.installa- tion to keep it running safely and efficiently. These pro - cedures should be performed only by a qualified service person.....
Page 17 - ConVeRsIon kIT CoMPonenTs; Must be; Important: Perform a leak test upon completion
1 Appendix.A ConVeRTInG THe ClaRITY b-VenT fRoM one Gas To anoTHeR In THe fIelD noTe: THe ConVeRsIon sHall be CaR- RIeD oUT In aCCoRDanCe WITH THe Re- qUIReMenTs of THe PRoVInCIal oR loCal aUTHoRITIes HaVInG JURIsDICTIon anD In aCCoRDanCe WITH ReqUIReMenTs of THe CURRenT eDITIon of THe naTIonal fUel...
Page 18 - De-RaTInG foR HIGH alTITUDe; naTURal Gas
1 Appendix.B De-RaTInG foR HIGH alTITUDe For. U.S.. installations,. the. Clarity. B-Vent. is. approved. for.elevations.up.to.2000.feet.using.the.factory-installed. burner.injectors..At.elevations.above.2000.feet,.U.S..codes. require.a.decrease.in.the.input.rating.by.changing.the.burner. injectors. t...
Page 19 - Gas Heater Specifications
1 Clarity.B.Vent.. Gas Heater Specifications Tested.to.ANSI.Z21.88-2002,.CSA.2.33-M02,.CAN/CGA.2.17-M91. . naTURal Gas PRoPane Input.Rating.(Btu/hr).(0-1375.m). 40,000. 40,000 Min..Input.Rating.(Btu/hr)..(0-1375.m). 27,000. 28,000 Injector.Sizes.(DMS).(front/center/rear..(0-1375.m). 47/56/39. 56/71/...