Page 2 - Technical Information; Recommended water pressure; Talis S2
2 Technical Information Recommended water pressure 15 - 72 psi Max. water pressure 116 psi Max. hot water temp. 176 o F* Recommended hot water temp. 120 o F - 140 o F* Flow rate 1.6 gpm Battery (32210/32212 only) CR-P2 / 6 V Lithium Automatic shutoff after 1 min. *Please know and follow all local pl...
Page 4 - Installation notes; not
4 Installation notes • Flush the hot and cold supplies thoroughly before installing the faucet. Damage to the faucet caused by debris is not covered under the warranty. • The hot and cold supplies should be of equal pressure. • The faucet should not be used with a con- tinuous flow water heater. • D...
Page 5 - Installation; Tighten the hoses with two wrenches, as shown, to
5 Installation Position the faucet on the sink or countertop (1). Install and tighten the mounting nut (2). Tighten the tensioning screws (3). Connect the 3/8” adapters to the stops (4). Connect the hoses to the adapters (5). Tighten the hoses with two wrenches, as shown, to prevent the hoses from t...
Page 6 - Temperature adjustment -; Wait 30 seconds
6 Temperature adjustment - 32111XX1 / 32113XX1 only Turn the water supplies off (1). Disconnect the faucet power cable from the battery pack or AC power pack (2). Remove the screw from the rear of the faucet (3). Connect the faucet power cable to the battery pack or AC power pack (1). Plug the AC po...
Page 8 - Battery replacement
8 Battery replacement -- models 32110XX1 / 32111XX1 only If the LED in the sensor window flashes, the battery is low, but the faucet can still be used. If the LED lights continuously, the battery must be changed before the faucet can be used. Remove the four screws and the battery pack cover. Remove...
Page 9 - Clean the aerator and filters; If the water flow is reduced over time, clean the aerator
Clean the aerator and filters -- all models If the water flow is reduced over time, clean the aerator (a) and the filters (b). Turn the water supplies off (1). Disconnect the power cable (2). Unscrew the aerator (a) with the service key. Disconnect the hot and cold supply hoses from the adapters. Re...
Page 10 - Place a hand in front of the sensor to turn the faucet on (2).
10 Wait 30 seconds (1). Place a hand in front of the sensor to turn the faucet on (2).
Page 11 - Cleaning
11 Cleaning The faucet may be turned off temporarily so that the sink may be cleaned. Cover the sensor window with a hand for approximately 10 seconds. The faucet will turn off for approximately 60 seconds, so that the sink may be cleaned. The LED in the sensor window will flash. When the LED no lon...
Page 12 - Reduce the sensor range; If the card or hand is removed in less
12 Reduce the sensor range The sensor is set for maximum range at the factory. If the faucet is used on a very small or highly reflective lavatory, the sensor range may be reduced by ap- proximately 2”. Disconnect the power cable for approximately 10 seconds (1). Reconnect the power cable (2). The L...
Page 13 - Replacement Parts; Maintenance note
13 Replacement Parts 1 aerator 8802XX0 2 fixing set 1361000 3 AC adapter 4 battery, lithium CR-P2 / 6V 5 battery box 8801000 6 connection hose 880000 7 electronics 8803000 8 check valve 6456000 aerator service key 8808000 Maintenance note : the check valves (item #8) should be removed and checked ye...