Page 2 - Caution; : Do not bend or twist the supply hoses!; Technical Data
Metris Electronic Lavatory Faucet with Temperature Control 31100XX1 Metris Electronic Lavatory Faucet 31101XX1 Caution : Do not bend or twist the supply hoses! Technical Data Max. water pressure 116 psi Recommended pressure 14.5 - 7 psi Max. hot water temp. 158°F* Recommended hot water temp. 10°F - ...
Page 3 - Installation; Flush the hot and cold supplies thoroughly before install-
3 Installation Flush the hot and cold supplies thoroughly before install- ing this faucet.Place the faucet in the hole on the mounting surface (1).Tighten the mounting nut ().Install the adapters and filters on the stops (3).Install the supply lines (4). Be careful not to twist the supply lines, or ...
Page 4 - : Pivot the temperature control; Model 31101 only: Set the temperature; the screw to the rear to make the water warmer, to the
4 Turn the water on to the faucet (1).Peel the protective film from the sensor ().Wait 15 seconds, the place a hand in front of the sensor (3). The water should turn on automatically. Model 31100 only : Pivot the temperature control lever forward to make the water cooler (4). Model 31101 only: Set t...
Page 5 - Remove the handle screw and handle (model 31100
5 Cleaning: Block the sensor for 5 seconds (1). This will turn the water off for approximately 90 seconds, so that the sink may be cleaned (). Faucet MaintenanceReplace the battery When the battery is low, the sensor will flash.Remove the set screw from the back of the faucet (1). Remove the handle ...
Page 6 - Remove the set screw with a .5 mm
6 Reset the faucet: Remove the set screw with a .5 mm Allen wrench.Block the sensor for seconds. Wait 10 seconds (1), then replace the set screw (). Wait 15 seconds (3). Place a hand in front of the sensor (4). The water should turn on.
Page 7 - Clean the filters and aerator; If the flow of water is reduced, the aerator and/or the; To clean the aerator:; Block the sensor for 5 seconds to temporarily shut off the; To clean the filters:; and clean the filters.
7 Clean the filters and aerator If the flow of water is reduced, the aerator and/or the filters must be cleaned. To clean the aerator: Block the sensor for 5 seconds to temporarily shut off the water (1).Unscrew and remove the vandal resistant aerator using the enclosed key (). Flush any debris from...
Page 8 - Replacement Parts; Important note
8 Replacement Parts 1 aerator 9861000 solenoid valve 96904000 3 fixation set 9781000 4 connection hose 98809000 5 check valve 96456000 6 electronics 96905000 7 battery 97399000 Important note : the check valves should be removed and inspected yearly. 1 3 4 5 6 7
Page 9 - Cleaning Recommendation for Hansgrohe Products
9 Cleaning Recommendation for Hansgrohe Products Modern lavatory faucets, kitchen faucets, and showers consist of very different materials to comply with the needs of the market with regard to design and functionality. To avoid damage and returns, it is necessary to consider certain criteria when cl...
Page 10 - Limited Lifetime Consumer Warranty
10 Limited Lifetime Consumer Warranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either th...
Page 12 - 490 Bluegrass Lakes Parkway
Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 Tel. 770 360-9880 • Fax 770 360 9887 www.hansgrohe-USA.com US - Installation Instructions • Par t No. 905900 1 • Revised 05/ 008