Page 2 - Max. flow rate of showerhead
2 Raindance Allrounder 28110XX1 Technical Data Max. flow rate of showerhead 2.5 gpm Determining the mounting height (X) The Allrounder should be mounted according to the preferences of the users. It should be conve- nient for all adult users.
Page 3 - If you are not using the 28108XX1 wall outlet adapter, go to page 9; brass; nipple required to install the wall outlet
Install the Allrounder with the Optional Wall Outlet Adapter with Hose Connection 28108XX1 Roughing in If you are not using the 28108XX1 wall outlet adapter, go to page 9 . Install a properly anchored 1/2" NPT drop-eared ell, at least 2" behind the surface of the finished wall. Install a tes...
Page 4 - Installation; Do not overtighten, or damage will
Installation Wrap both ends of the brass nipple with Teflon tape. Screw it into the mounting piece. Screw the test nipple / mounting piece assembly into the drop-eared ell. Tighten with a 12 mm Allen wrench (not included). Position the mounting plate over the mounting piece. Use a grease pencil or s...
Page 5 - Seal the wall around the anchors; Install the mounting plate, using the screws and offset
5 Drill the holes with a 6 mm bit. Use extreme caution - do not drill into the water line. Install the anchors. Remove the long bottom mounting screw on the All- rounder. Replace with the shorter screw included with the adapter. Seal the wall around the anchors with waterproof sealant.Failure to sea...
Page 6 - Install the handshower; Place a black rubber washer in one end of the hose.
6 Slide the handshower into the handshower holder. Guide the hose over the hose hook. Install the handshower Place a black rubber washer in one end of the hose. Screw this end to the wall outlet adapter.Place the screen washer in the other end of the hose. Screw this end to the handshower. Attach th...
Page 7 - Replacement Parts; check valve; Check Valve Maintenance:; tion is provided by a check valve, which is integral
Replacement Parts 28108001 1 check valve 90000 2 screw 9598000 Check Valve Maintenance: Backflow preven- tion is provided by a check valve, which is integral to the wall outlet adapter. The check valve should be removed and cleaned yearly. 1 2
Page 8 - Install the corner mount with the screws and offset
8 Corner Mount Kit 28105XX0 Note: The corner mount kit is not for use with the 28108XX1 wall outlet adapter. Position the corner mount against the wall at the desired location. Mark the positions of the screw holes. Put the mount aside.Drill the holes using a 6 mm bit. Seal the wall around the ancho...
Page 9 - Do not drill through the mounting plate.; Place the mounting plate against the wall at the de-
9 Install the 28110XX1 Allrounder Do not drill through the mounting plate. Put the mounting plate away in a safe location.Drill the holes, using a 6 mm bit. Place the mounting plate against the wall at the de- sired location. Mark the locations of the screw holes.
Page 10 - Install the handshower:
10 Place the Allrounder over the mounting bracket (1). Tighten the set screw (2). Install the handshower: Place a black rubber washer in one end of the hose. Connect this end of the hose to the wall outlet (not included). Place the screen washer in the other end of the hose. Screw it to the handshow...
Page 11 - Slide the handshower into the holder, until the holder; Using the Allrounder; Turn the knob to the front to make the Allrounder
11 Slide the handshower into the holder, until the holder grips it firmly. Guide the hose over the hose hook. Using the Allrounder To adjust the handshower height:Pull or push the Allrounder to the desired position. Turn the knob to the front to make the Allrounder easier to move. Turn the knob to t...
Page 12 - Change the spray modes; Limescale Removal; function lever
12 Change the spray modes Push the function lever until it is next to the name of the desired function. The Raindance has spray modes. Limescale Removal The spray channels on the Raindance are protected by the Rubit!™ self-cleaning system. If scale deposits are noticed, turn the water on lightly and...