Page 2 - T A B L E O F C O N T E N T S; is guaranteed for two years against defects in workmanship; W A R R A N T Y
2 Dear Customer,Thank you for choosing a Hanna Instruments Product.Please read this instruction manual carefully before using the instrument.This manual will provide you with all the necessary information for thecorrect use of the instrument, as well as a precise idea of its versatilityin a wide ran...
Page 3 - P R E L I M I N A R Y E X A M I N A T I O N
3 Remove the instrument from the packing material and examine itcarefully to make sure that no damage has occurred during shipping.If there is any damage, notify your Dealer.Each thermometer is supplied complete with: • HI762BL Temperature Probe • 1.5V AA Alkaline Batteries (4 pcs) • Paper rolls (5 ...
Page 5 - F U N C T I O N A L D E S C R I P T I O N; key, to move the paper up
5 F U N C T I O N A L D E S C R I P T I O N 1) Power adapter plug2) Temperature Probe Connector3) Liquid Crystal Display (LCD)4) PAPER key, to move the paper up 5) ON/OFF key, to turn the meter on or off 6) ALT key, to alternate key function 7) TEMP/TIME key, to select temperature reading, to view d...
Page 6 - S P E C I F I C A T I O N S; Range; channel
6 S P E C I F I C A T I O N S Range -50.0 to 150.0 °C ; -55.0 to 300.0 °F Resolution 0.1 °C (-30 °C to +130 °C); 0.2 °C outside0.1 °F (-18 °F to 225 °F);0.2 °F (225°F to 260 °F); 0.3 °F outside Accuracy ±0.4 °C (-20 °C to +120°C); ±0.7 °C outside (@20°C/68°F) ±0.8 °F (-4 to +248 °F); ±1.3 °F outside...
Page 7 - I N I T I A L P R E P A R A T I O N; ALT
7 I N I T I A L P R E P A R A T I O N Each meter is supplied complete with batteries. Remove the backcover, unwrap the batteries and install them while paying attention tothe polarity. Alternatively, connect the HI 710005 or HI 710006voltage adapter to the power adapter plug.To prepare the instrumen...
Page 8 - S E T U P M O D E
8 Setup can be used to view data regarding the instrument status(e.g. battery charge) or GLP data (e.g. calibration date) or to viewor print the logged data. It also allows the user to change the meterparameters (e.g. time) and to gain access to stored data. • To enter setup mode, ensure the meter i...
Page 10 - SETUP MESSAGES LIST
10 Code Valid values Default 10 Show GLP data11 Calibration alarm time-out On(enabled); Off(disabled) On 20 Instrument ID code 0000÷9999 0000 30 Current time 1 hh:mm 00:00 31 Current day 1 dd 01 32 Current month 1 MM 01 33 Current year 1 YYYY 2004 40 Auto-Off/Power down time-out Off,5,10,15,30,45,60...
Page 11 - SCAN LOGGED DATA RECALL
11 Note: The Sample ID is stored in the log memory as a 14 digithexadecimal code. Only the last 6 digits will be displayed onthe LCD: two (the least significant) on the lower LCD, and thenext four on the upper LCD. Example: If the Sample ID is 010000012C354B: If the Sample ID code is null: Also only...
Page 14 - T A K I N G T E M P E R A T U R E M E A S U R E M E N T S
14 To prepare the instrument for use, choose the most appropriatetemperature probe for your application (see accessories) and connect itto the connector located on the top of the instrument.All the probes have been factory precalibrated and no calibration isneeded.Press ON/OFF to power on the instru...
Page 15 - TIMED LOGGING MODE; P R I N T I N G / L O G G I N G F U N C T I O N S
15 Two different modes to print / log data are available:1. Timed Logging ; samples are stored and printed (if print function is active) at fixed time intervals. Data are stored in the lots 01 to 16. 2. Log on Demand ; samples are stored and printed (if print function is active) when the LOG key is ...
Page 16 - STOP LOGGING; LOW BATTERY CONDITION
16 c - Sample ID (only for the first sample of the lot)d - Date (only for the first printed sample of the lot or of the day)e - Sample numberf - Timeg - Reading ("----" means out of range). If no keys are pressed, the meter enters sleep mode to prolong thebattery life and only the "LOG...
Page 18 - RETRIEVE LOGGED DATA
18 last logged lot in the lower LCD and the number of logged samples inthe upper LCD are displayed. It is then possible to scroll through thefollowing lot information with the à à à à à key: • Sample ID• lot starting date (dd.mm)• lot starting year• lot starting time (hh.mm)• lot logging intervalBy ...
Page 19 - O T H E R F E A T U R E S; LCD BACKLIGHT; G O O D L A B O R A T O R Y P R A C T I C E ( G L P ); LAST CALIBRATION DATE
19 O T H E R F E A T U R E S LCD BACKLIGHT The LCD can be illuminated to allow the user to see the readings evenin dark environments. This feature can be enabled/disabled pressingthe ALT and LIGHT keys. If the LCD backlight feature is enabled, the LCD remains illuminated until the feature is disable...
Page 20 - D A T A T R A N S F E R T O P C
20 Windows ® is registered Trademark of "Microsoft Co." Excel © Copyright "Microsoft Co." Lotus 1-2-3 © Copyright "Lotus Co." HI 98811 contains infrared transmitting circuitry. Ensure there isn't any logging process active.Press TEMP/TIME to set the meter to time or date mode...
Page 21 - M E M O R Y O R G A N I Z A T I O N; MEMORY CAPACITY; The oldest lot data are erased without any warning message.
21 M E M O R Y O R G A N I Z A T I O N Logged data are stored in the internal EEPROM and are retained evenif batteries and external power are disconnected. MEMORY CAPACITY • 12900 data samples divided into 16 lots (lots 01 to 16)• 9999 data samples maximum in one single lot• 300 data samples for the...
Page 22 - P R I N T E R M A I N T E N A N C E; CHANGE THE INK CARTRIDGE; PAPER; PRINTER ERROR; Motor locked; C BUS ERROR; In case of an I; F A U L T C O N D I T I O N S
22 P R I N T E R M A I N T E N A N C E CHANGE THE INK CARTRIDGE When printouts become faint, it might be necessary to change the inkcartridge. Contact your Hanna authorized center. INSERT THE PAPER ROLL The meters use plainpaper rolls, 38 mmwidth. To insert a newroll open the papercover pulling it g...
Page 23 - B A T T E R Y R E P L A C E M E N T
23 When the batteries are inserted and no power adapter is connected,the meter can recognize different batteries charge levels.1. Fully charged batteries . The backlight and printer can be enabled. 2. Weakening batteries - "LOBAT" symbol blinks on LCD. The backlight and printer are automatic...
Page 24 - T E M P E R A T U R E P R O B E S
24 HI 762A Air probe, 1 m (3.3') cable and white handle HI 762A/10 Air probe, 10 m (33') cable and white handle HI 762BL General purpose liquid probe, 1m (3.3') cable, black handle HI 762L General purpose liquid probe, 1m (3.3') cable, white handle HI 762L/2 General purpose liquid probe, 2m (6.6') c...
Page 25 - U N - H O U S E D N T C S E N S O R S
25 Often it is necessary to "customize" testing to meet specific criteria inthe laboratory. For this reason, Hanna offers a wide line of NTCThermistor sensors that can be custom mounted in almost any situation.Select the sensor that matches your application, attach it to the RCAadaptor and p...
Page 26 - A C C E S S O R I E S
HI 76S2-5 NTC Thermistor sensor. Aluminum tab with mountinghole. HI 76S2-6 NTC Thermistor sensor. PVC encapsulated tip for protectionin aggressive environments. HI 76S2-7 NTC Thermistor sensor. Can be housed and used in anycustom application. 1.6mm 0.06" 4.7mm 0.19" 12.7mm 0.50" ALUMINUM...
Page 28 - SALES AND TECHNICAL SERVICE CONTACTS
28 MAN9881 1 05/05 Australia: Tel. (03) 9769.0666 • Fax (03) 9769.0699 China: Tel. (10) 88570068 • Fax (10) 88570060 Egypt: Tel. & Fax (02) 2758.683 Germany: Tel. (07851) 9129-0 • Fax (07851) 9129-99 Greece: Tel. (210) 823.5192 • Fax (210) 884.0210 Indonesia: Tel. (21) 4584.2941 • Fax (21) 4584....