Page 3 - Warning Labels; Located on front splash panel and lid of machine.; CAUTION
Warning Labels The following warning labels were on your dispenser when it was shipped from the factory. They should remain on your dispenserin good, readable condition at all times. If one of your labels is missing or damaged, order a replacement label immediately. Part # A546-445 Located on front ...
Page 4 - ELECTRIC SHOCK HAZARD!; ) Remove the brewer from the packing material and attach its legs.
Page 4 Shuttle Brewers & Airpot/Shuttle Brewers Installation WA R N I N G ELECTRIC SHOCK HAZARD! Installation of this appliance should be performed by qualified service personnel only. Improperinstallation could result in electrocution. Set-Up/Position 1) Remove the brewer from the packing mater...
Page 5 - WA R N I N G; will make a subtle hissing sound while filling.
Shuttle Brewers & Airpot/Shuttle Brewers Page 5 Installation (cont.) Electric Hook-up The brewer is designed to operate at the specified voltage on the nameplate with a tolerance of ± 10% for voltagedeviation. It is very important that the power line to the brewer be checked to make sure that th...
Page 6 - ) If ready lights are lit, press correct batch size button.; C A U T I O N
Page 6 Shuttle Brewers & Airpot/Shuttle Brewers Operation C A U T I O N HOT LIQUID HAZARD! Water used for brewing coffee is very hot. Use caution when brewing, pouring, or transporting coffee. Accidental spills may result in severe burns. 1) Place an empty, warm Shuttle on the shelf, under the...
Page 7 - Adjustments; Temperature Adjustment; During this routine, no pulsing or bypass will occur.; Ratio “rto”; Approximate ratio numbers:
Shuttle Brewers & Airpot/Shuttle Brewers Page 7 Adjustments All adjustments to machine are accessible through the front display(s). Refer to specifics below and theProgramming Routine section. All values are preset at the factory and may vary brewer to brewer. Temperature Adjustment Tank tempera...
Page 8 - automatically reduced as bypass percent increases.; Brew Routine; No Pulse Brewing or Bypass
Page 8 Shuttle Brewers & Airpot/Shuttle Brewers Adjustments (cont.) Bypass “b-P” Brewer contains a bypass valve to control the amount of water to bypass coffee grounds and dilute the final brew. Bypass is available on Large and Medium brew cycles.Within the Programming Routine, the percent of th...
Page 9 - Programming; Settings Routine; Programming For All Brewer Settings and; Large
Shuttle Brewers & Airpot/Shuttle Brewers Page 9 Programming (All values are preset at the factory and may vary brewer to brewer.) Settings Routine Programming For All Brewer Settings and Large Portion (refer to Table 1) 1 1. Press and hold both “up” and “down” arrows for 5 seconds. 1 2. All thre...
Page 10 - Programming For All Brewer Settings and Large Portion (cont.); Table 1
Page 10 Shuttle Brewers & Airpot/Shuttle Brewers Programming For All Brewer Settings and Large Portion (cont.) Table 1 ADJUST OR TO LOW-TEMP/NO-BREW NO-BREW LOW-TEMP/ BYPASS RATIO ADVANCE ) BYPASS % (OFF, 1-33) BYPASS RATIO (0.20-1.25) BYPASS (MAX CHANGE DEPENDING ON RATIO # of seconds shown PUL...
Page 11 - Programming For; Medium; Press and hold both “up” and “down” arrows for 5 seconds.; Table 2
Shuttle Brewers & Airpot/Shuttle Brewers Page 11 Programming (cont.) Settings Routine Programming For Medium : Brew Time, Pulse Brewing & Bypass (refer to Table 2) 1 1. Press and hold both “up” and “down” arrows for 5 seconds. 1 2. All three brew lights will flash. 1 3. Press “Medium Brew” b...
Page 12 - Small; Table 3
Page 12 Shuttle Brewers & Airpot/Shuttle Brewers Programming (cont.) Settings Routine Programming For Small : Brew Time & Pulse Brewing (refer to Table 3) 1 1. Press and hold both “up” and “down” arrows for 5 seconds. 1 2. All three “brew” lights will flash. 1 3. Press “Small Brew” button. O...
Page 13 - Urn cleaners that have been used successfully:
Shuttle Brewers & Airpot/Shuttle Brewers Page 13 Cleaning WA R N I N G Burn Hazard! Hot liquids and surfaces are present in this equipment. To avoid burns use caution when cleaning.Rinse hot parts with cold water before cleaning. Use gloves or a heavy cloth when removing hotparts from brewer. Af...
Page 14 - Service; common service tasks; Drain Water Tank; Remove Brew Valve
Page 14 Shuttle Brewers & Airpot/Shuttle Brewers Service The rest of this manual contains information to aid the service person who is working on this equipment. This pagehas information on performing common service tasks . Following this is the Troubleshooting section which can help diagnose pr...
Page 15 - Special Control Functions; User Lockout; 0 Pin Version; System Restore Function; Factory Specific Features; Factory/Field Test Menu
Shuttle Brewers & Airpot/Shuttle Brewers Page 15 Special Control Functions User Lockout User Lockout is achieved via the position of the LOCK jumper on the board header. Locate the header on the board(shown below) and place the jumper in the desired position. In the Locked position all menus in ...
Page 17 - Troubleshooting; Error Messages; Initial; Filling Problems
Shuttle Brewers & Airpot/Shuttle Brewers Page 17 Troubleshooting The following pages are provided to help determine the cause of problems with operation of the brewers and to indicate the appropriate solution for the problems. For each problem, the possible causes should be checked in the order ...
Page 18 - Problem; Tank does not refill; “No power to control
Page 18 Shuttle Brewers & Airpot/Shuttle Brewers Troubleshooting (cont.) Filling Problems Problem Possible Causes Service Check Remedy Tank does not refill • No electrical power to equipment • No water supplied to equipment • No power to control board • No power to control board and transformern...
Page 19 - Heating Problems; Tank does not heat
Shuttle Brewers & Airpot/Shuttle Brewers Page 19 Troubleshooting (cont.) Filling Problems Problem Possible Causes Service Check Remedy Tank does not refill • Fill valve or control board is faulty • Check to ensure proper connection between 6 pin connector and con-trol board. Check for proper con...
Page 21 - Brewing Problems
Shuttle Brewers & Airpot/Shuttle Brewers Page 21 Troubleshooting (cont.) Heating Problems Problem Possible Causes Service Check Remedy Tank does not heat • Contactor faulty. • Heater faulty. • Control board is faulty. • Ensure that coil on contactor is energizedby ensuring that there is proper v...
Page 22 - Note: Small variations from batch to batch are normal.
Page 22 Shuttle Brewers & Airpot/Shuttle Brewers Troubleshooting (cont.) Brewing Problems Problem Possible Causes Service Check Remedy Brew volume toolarge or too small • Sprayhead clogged. • Brew valves clogged with lime deposits. • Water supply pressure or flow rate not adequate. • Visually ch...
Page 24 - Parts List for All Precision Brew Models
Page 24 Shuttle Brewers & Airpot/Shuttle Brewers ITEM DESCRIPTION PART # Reference Front View Picture: 1 Controller PB Single A530-056 ( prior to May 2007) ; A530-059 (after May 2007) 2 Relay, Heater 24vdc A531-072 ( prior to May 2007) ; A71450 (after May 2007) 3 Valve, Inlet 24vac A537-189 4 Te...
Page 26 - Heater Model shown
Page 26 Shuttle Brewers & Airpot/Shuttle Brewers Top View (refer to key on page 24) 42 30 34 Tank Lid (refer to key on page 24) 3 Heater Model shown 50 52 51 50 36 35 38 35 32 36
Page 27 - Shuttle Parts List
Shuttle Brewers & Airpot/Shuttle Brewers Page 27 ITEM DESCRIPTION PART # 1 Faucet Model ES A537-053 2 Shank w/ Chrome Bonnet A522078 3 Gauge Assembly A718-018 4 Kit, Shuttle Lid A725-092 S.S. Shuttle Cover(not shown)* A713-027 5 Lid Retaining Clip A548-142 6 Lid Stopper w/ O-Ring A548-140A61365 ...
Page 28 - VS
Page 28 Shuttle Brewers & Airpot/Shuttle Brewers VS- 1.5S VS -S 3 1 8 5 2 9 6 7 4 5 1 4 6 2 3 7 8 ITE M NO . Tit le P ART NU M B E R V S -1 .5 S/Q TY. 1 S ta n d Bo d y A548-157 1 2 Tra y fo r Sta n d A 548-159 1 3 V ac uum S h uttl e V S -1 .5 1 4 S ta n d Ba se A548-158 1 5 Tra y T o p A 517-0...
Page 29 - solution for cleaning.; ) Cleaning the Faucet assembly and silicone tube:; Cleaning & Sanitizing Instructions
Shuttle Brewers & Airpot/Shuttle Brewers Page 29 These cleaning and sanitizing instructions are only a guideline to be used for the cleaning and sanitizing of the VS-1.5S and VS-S with VS-1.5. In-house cleaning and sanitizing methods may be more effective. Grindmasterassumes no responsibility fo...
Page 30 - Wiring Diagram - Precision Brew 430 Series; Prior
Page 30 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram - Precision Brew 430 Series Models PB-430, PBVSA-430, and PBIC-430 Prior to May 2007
Page 31 - Wiring Diagram - Precision Brew 330 Series
Shuttle Brewers & Airpot/Shuttle Brewers Page 31 Wiring Diagram - Precision Brew 330 Series Models PB-330, PBVSA-330, and PBIC-330 Prior to May 2007
Page 32 - Wiring Diagram
Page 32 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram PB-430E 230V, PBVSA-430E230V, PBIC-430E 230V (Single or Three Phase Models) Prior to May 2007
Page 34 - After
Page 34 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram - Precision Brew 430 Series Models PB-430, PBVSA-430, and PBIC-430 After May 2007