Page 2 - omenClature
P roduCt S PeCifiCationS P roduCt S PeCifiCationS 2 www.goodmanmfg.com SS-CPH90-150 n omenClature C P H 090 045 3 B X X X 1 2 3 4,5,6 7,8,9 10 11 12 13 14 Brand Factory-‐Installed Op<ons C Commercial X No Op:ons A Non-‐powered convenience outlet Configura<on B Powered convenience outl...
Page 3 - roduCt; — 71⁄2 t; onS; Cooling Capacity; Locating Dimple
P roduCt S PeCifiCationS P roduCt S PeCifiCationS SS-CPH90-150 www.goodmanmfg.com 3 P roduCt S PeCifiCationS — 7½ t onS CPH090 ***3B*** CPH090 ***4B*** CPH090 ***7B*** Cooling Capacity Total BTU/h 90,000 90,000 90,000 Sensible BTU/h 65,700 65,700 65,700 EER / IEER 11.5 / 11.2 11.5 / 11.2 11.5 / 11.2...
Page 4 - — 81⁄2 t; Standard Max Static
P roduCt S PeCifiCationS P roduCt S PeCifiCationS 4 www.goodmanmfg.com SS-CPH90-150 P roduCt S PeCifiCationS — 8½ t onS CPH102 ***3B*** CPH102 ***4B*** CPH102 ***7B*** Cooling Capacity Total, BTU/h 102,000 102,000 102,000 Sensible BTU/h 73,440 73,440 73,440 EER / IEER 11.1 / 11.2 11.1 / 11.2 11.1 / ...
Page 5 - Orifice; Belt Drive Evap Fan Data; Belt-Driven Standard Max Static
P roduCt S PeCifiCationS P roduCt S PeCifiCationS SS-CPH90-150 www.goodmanmfg.com 5 P roduCt S PeCifiCationS — 10 t onS CPH120 ***3B*** CPH120 ***4B*** CPH120 ***7B*** Cooling Capacity Total BTU/h 118,000 118,000 118,000 Sensible BTU/h 87,300 87,300 87,300 EER / IEER 11.5 / 11.5 11.5 / 11.5 11.5 / 1...
Page 7 - xPanded; Outdoor Ambient Temperature
P roduCt S PeCifiCationS P roduCt S PeCifiCationS SS-CPH90-150 www.goodmanmfg.com 7 e xPanded H eating d ata CPH090 Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 114.4 108.3 101.9 95.3 91.0 88.2 81.9 75.5 70.5 65.0 59.9 56.6 54.5 48.9 43.3 37.8 32.2 26.4 T/R 35...
Page 16 - irflow
P roduCt S PeCifiCationS P roduCt S PeCifiCationS 16 www.goodmanmfg.com SS-CPH90-150 a irflow d ata — 7½ t onS Standard Belt Drive — Down Shot ESP, In H 2 O Turns Open 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0.1 3617 704 1.07 3293 653 0.84 0.3 3541 749 1.1...
Page 20 - eat; inimum; kw C; orreCtion
P roduCt S PeCifiCationS P roduCt S PeCifiCationS 20 www.goodmanmfg.com SS-CPH90-150 H eat k it e leCtriCal d ata — 7½ t onS m inimum a irflow for e leCtriC H eat Heater Size (kW) Minimum CFM 15 3,000 30 3,000 43 3,000 kW Correction Factor for 3-Phase Units Supply Voltage 240 230 220 210 208 Correct...
Page 21 - w C; kW Correction Factor for 480V Units; Actual Voltage; kW Correction Factor for 575V Units; Supply Voltage; Horizontal
P roduCt S PeCifiCationS P roduCt S PeCifiCationS SS-CPH90-150 www.goodmanmfg.com 21 H eat k it e leCtriCal d ata — 8½ t onS Model and Heat Kit Usage MCA¹ at 240V MOP² (amps) at 240V Actual kW at 240V Recommended Airflow Range (Downshot) Recommended Airflow Range (Horizontal) CPH102***3B*** 43 50 EH...
Page 24 - imenSionS; APPENDIX C UNIT DIMENSIONS; Model
P roduct S PecificationS P roduct S PecificationS 24 www.goodmanmfg.com SS-CPH90-150 d imenSionS 20 APPENDIX C UNIT DIMENSIONS Horizontal Discharge Vertical Discharge (Bottom of Unit) RETUR N SUPPLY 13 7/8” 28 3/8” 7 3/8” 12 5/8” 6 1/4” 36 3/8” 5 7/8” RETURN SUPPL Y 5 3/8” 7 1/2” 6 1/2” 99 1/8” 61 3...
Page 25 - nit; High-Voltage Entrance
P roduct S PecificationS P roduct S PecificationS SS-CPH90-150 www.goodmanmfg.com 25 48” 36” Min. 48” 48” 75” u nit c learanceS e lectrical e ntrance l ocationS 11⅝” 10 3 / 16 ” 3” Low-Voltage Entrance High-Voltage Entrance Dimples Mark Drill Locations Maintain an adequate clearance around the unit ...
Page 26 - oof; Unit Weights; Weight A
P roduct S PecificationS P roduct S PecificationS 26 www.goodmanmfg.com SS-CPH90-150 r oof c urb i nStallation — r igging Provisions for forks have been included in the unit base frame. No other fork locations are approved. • Unit must be lifted by the four lifting holes located at the base frame co...
Page 27 - curb and package unit.; Power Wiring
P roduCt S PeCifiCationS P roduCt S PeCifiCationS SS-CPH90-150 www.goodmanmfg.com 27 r oof C urB i nStallation ( Cont .) Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association.Proper unit installation requires that...
Page 28 - iring
P roduCt S PeCifiCationS P roduCt S PeCifiCationS 28 www.goodmanmfg.com SS-CPH90-150 w iring d iagram — CPH090-120***3B/ 4B ( for modelS witH Serial numBerS 0907 and Below ) Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ W arning High Vo...
Page 34 - CCeSSorieS
P roduCt S PeCifiCationS P roduCt S PeCifiCationS 34 www.goodmanmfg.com SS-CPH90-150 a CCeSSorieS Item # Description Fits Model Sizes 14CURB90150 Roof Curb 14" Tall 7½-12½ tons 25FD90150 25% Manual Fresh Air Damper 7½-12½ tons 25MFD90150 25% Motorized Fresh Air Damper 7½-12½ tons BRD3672 Horizon...
Page 35 - oteS
P roduCt S PeCifiCationS P roduCt S PeCifiCationS SS-CPH90-150 www.goodmanmfg.com 35 n oteS