Page 2 - omenClatUre
P rodUCt s PeCiFiCations P rodUCt s PeCiFiCations 2 www.goodmanmfg.com SS-CPG36-72 n omenClatUre C P G 036 045 3 B X X X 1 2 3 4,5,6 7,8,9 10 11 12 13 14 Brand Factory-‐Installed Op<ons C Commercial X No Op:ons A Non-‐powered convenience outlet Configura<on B Powered convenience outle...
Page 3 - rodUCt; Cooling Capacity
P rodUCt s PeCiFiCations P rodUCt s PeCiFiCations SS-CPG36-72 www.goodmanmfg.com 3 P rodUCt s PeCiFiCations — CPG036 B m odels CPG036 0451DXXX CPG036 0453DXXX CPG036 0453BXXX CPG036 0454BXXX Cooling Capacity Total BTU/h 34,600 34,600 34,600 34,600 Sensible BTU/h 25,600 25,600 25,600 25,600 SEER / EE...
Page 4 - Indoor Nominal CFM
P rodUCt s PeCiFiCations P rodUCt s PeCiFiCations 4 www.goodmanmfg.com SS-CPG36-72 P rodUCt s PeCiFiCations — CPG036 B m odels ( Cont .) CPG036 0901DXXX CPG036 0903DXXX CPG036 0903BXXX CPG036 0904BXXX CPG036 0907BXXX Cooling Capacity Total BTU/h 34,600 34,600 34,600 34,600 35,000 Sensible BTU/h 25,6...
Page 10 - irFlow
P rodUCt s PeCiFiCations P rodUCt s PeCiFiCations 10 www.goodmanmfg.com SS-CPG36-72 a irFlow d ata — CPG036B s tandard d ireCt d rive — h orizontal s tandard d ireCt d rive — d own s hot CFM Static Amps Watts RPM Speed Tap CFM Static Amps Watts RPM Speed Tap 1293 0.1 1.72 364 715 Low 1313 0.10 1.68 ...
Page 14 - RPM
P rodUCt s PeCiFiCations P rodUCt s PeCiFiCations 14 www.goodmanmfg.com SS-CPG36-72 a irFlow d ata — CPG060B s tandard d ireCt -d rive — h orizontal s tandard d ireCt -d rive — d own s hot CFM Static Amps Watts RPM Speed Tap CFM Static Amps Watts RPM Speed Tap 1416 0.1 1.63 176 588 T1 1237 0.1 1.64 ...
Page 17 - xPanded
P rodUCt s PeCiFiCations P rodUCt s PeCiFiCations SS-CPG36-72 www.goodmanmfg.com 17 e xPanded C oolinG d ata — CPG036B Outdoor Ambient T emper ature 65 75 85 95 105 115 Entering Indoor W et Bulb T emper ature IDB Airfl o w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 13...
Page 25 - imensions; APPENDIX C UNIT DIMENSIONS; Horizontasl Discharge; RETUR N; Horizontal Discharge
P rodUCt s PeCiFiCations P rodUCt s PeCiFiCations SS-CPG36-72 www.goodmanmfg.com 25 d imensions 30 APPENDIX C UNIT DIMENSIONS Horizontasl Discharge Vertical Discharge NOTE For horizontal discharge, remove the supply and return duct covers and place them over the vertical discharge return and supply ...
Page 26 - nit; Power Thru
P rodUCt s PeCiFiCations P rodUCt s PeCiFiCations 26 www.goodmanmfg.com SS-CPG36-72 U nit C learanCes Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of 75” on the main control panel side of the unit for possible rem...
Page 27 - ooF; If using bottom discharge with roof curb, duct-work should be; Unit Weights; Unit Shipping Weight; Note: Weights are calculated without accessories installed.
P rodUCt s PeCiFiCations P rodUCt s PeCiFiCations SS-CPG36-72 www.goodmanmfg.com 27 r ooF C UrB i nstallation — r iGGinG Provisions for forks have been included in the unit base frame. No other fork locations are approved.• Unit must be lifted by the four lifting holes located at the base frame corn...
Page 28 - and return duct openings.; oP
P rodUCt s PeCiFiCations P rodUCt s PeCiFiCations 28 www.goodmanmfg.com SS-CPG36-72 r ooF C UrB i nstallation ( Cont .) Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association.Proper unit installation requires that ...
Page 29 - iring; ingle; arning; High
P roduct S PecificationS P roduct S PecificationS SS-CPG36-72 www.goodmanmfg.com 29 W iring d iagram — cPg0360451d (S ingle -P haSe , d irect d rive ) 2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYP...
Page 32 - hree
P roduct S PecificationS P roduct S PecificationS 32 www.goodmanmfg.com SS-CPG36-72 W iring d iagram — cPg060*3d (t hree -P haSe , d irect d rive ) Wiring is subject to change. Al wa ys refer to the wiring diag ram or the unit for the most up-to-da te wiring . ⚠ W arning High Voltage: Disconnect all...
Page 35 - elt
P roduct S PecificationS P roduct S PecificationS SS-CPG36-72 www.goodmanmfg.com 35 W iring d iagram — cPg036-600904B/7B — cPg036*4B/7B — cPg072*4B/7B (460v/575 v , B elt d rive ) Wiring is subject to change. Al wa ys refer to the wiring diag ram or the unit for the most up-to-da te wiring . ⚠ W arn...
Page 39 - CCessories; Description
P rodUCt s PeCiFiCations P rodUCt s PeCiFiCations SS-CPG36-72 www.goodmanmfg.com 39 a CCessories Item # Description Fits Model Sizes 14CURB3672B Roof Curb – 14" Tall 3-6 tons 25FD3672 25% Manual Fresh Air Damper 3-6 tons 25MFD3672 25% Motorized Fresh Air Damper 3-6 tons BRD3672 Horizontal Barome...
Page 40 - otes
P rodUCt s PeCiFiCations P rodUCt s PeCiFiCations 40 www.goodmanmfg.com SS-CPG36-72 Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2011 • Goodman Manufacturing Company, L.P. •...