Page 2 - omenclature
P roduct S PecificationS P roduct S PecificationS 2 www.goodmanmfg.com SS-CPC36-72 n omenclature C P C 060 015 3 B X X X 1 2 3 4,5,6 7,8,9 10 11 12 13 14 Brand Factory-‐Installed Op;ons C Commercial X No Op:ons A Non-‐powered convenience outlet Configura;on B Powered convenience outlet P Pa...
Page 3 - rodUCt; XXX1DXXX
p rodUCt s peCifiCations p rodUCt s peCifiCations SS-CPC36-72 www.goodmanmfg.com 3 p rodUCt s peCifiCations — CpC036 B m odels CPC036 XXX1DXXX CPC036 XXX3DXXX CPC036 XXX3BXXX CPC036 XXX4BXXX CPC036 XXX7BXXX Cooling CapacityTotal BTU/h 34,600 34,600 34,600 34,600 34,600 Sensible BTU/h 25,600 25,600 2...
Page 6 - XXX3BXXX
p rodUCt s peCifiCations p rodUCt s peCifiCations 6 www.goodmanmfg.com SS-CPC36-72 CPC072 XXX3BXXX CPC072 XXX4BXXX CPC072 XXX7BXXX Cooling CapacityTotal BTU/h 71,000 71,000 71,000 Sensible BTU/h 48,280 48,280 48,280 EER 11.2 11.2 11.2 Decibels 78.0 78.0 78.0 AHRI Number 3397631 3397631 3397631 Evapo...
Page 7 - Multiply rated kW by correction factor to get actual kW; w C; orreCtion
p rodUCt s peCifiCations p rodUCt s peCifiCations SS-CPC36-72 www.goodmanmfg.com 7 h eat k it e leCtriCal d ata (B lower o nly , h eat m ode ) — 3 t ons kW Correction Factor for 1- & 3-Phase Units Supply Voltage 240 230 220 210 208 Correction Factor 1 0.93 0.82 0.78 0.76 Multiply rated kW by cor...
Page 9 - For other voltage use voltage2
p rodUCt s peCifiCations p rodUCt s peCifiCations SS-CPC36-72 www.goodmanmfg.com 9 h eat k it e leCtriCal d ata (B lower o nly , h eat m ode ) — 5 t ons kW Correction Factor for 1- & 3-Phase Units Supply Voltage 240 230 220 210 208 Correction Factor 1 0.93 0.82 0.78 0.76 kW Correction Factor for...
Page 10 - For other voltage use voltage2 / 4802
p rodUCt s peCifiCations p rodUCt s peCifiCations 10 www.goodmanmfg.com SS-CPC36-72 h eat k it e leCtriCal d ata (B lower o nly , h eat m ode ) — 6 t ons kW Correction Factor for 3-Phase Units Supply Voltage 240 230 220 210 Correction Factor 1 0.92 0.84 0.77 kW Correction Factor for 480V Units Actua...
Page 11 - irflow
p rodUCt s peCifiCations p rodUCt s peCifiCations SS-CPC36-72 www.goodmanmfg.com 11 a irflow d ata — CpC036 d ireCt d rive — h orizontal d ireCt d rive — d own s hot CFM Static Amps Watts RPM Speed Tap CFM Static Amps Watts RPM Speed Tap 1296 0.1 1.67 356 764 Low 1287 0.1 1.66 350 770 Low 1245 0.2 1...
Page 18 - xpanded
p rodUCt s peCifiCations p rodUCt s peCifiCations 18 www.goodmanmfg.com SS-CPC36-72 e xpanded C ooling d ata — CpC036 Outdoor Ambient T emper ature 65 °F 75 °F 85 °F 95 °F 105 °F 115 °F Entering Indoor W et Bulb T emper ature IDB Airfl o w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 ...
Page 26 - imensions; APPENDIX C UNIT DIMENSIONS; Horizontasl Discharge; RETUR N; Horizontal Discharge
p rodUCt s peCifiCations p rodUCt s peCifiCations 26 www.goodmanmfg.com SS-CPC36-72 d imensions 30 APPENDIX C UNIT DIMENSIONS Horizontasl Discharge Vertical Discharge NOTE For horizontal discharge, remove the supply and return duct covers and place them over the vertical discharge return and supply ...
Page 27 - nit
p rodUCt s peCifiCations p rodUCt s peCifiCations SS-CPC36-72 www.goodmanmfg.com 27 U nit C learanCes Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of 75” on the main control panel side of the unit for possible rem...
Page 28 - oof; orner; Unit Shipping Weight
p rodUCt s peCifiCations p rodUCt s peCifiCations 28 www.goodmanmfg.com SS-CPC36-72 r oof C UrB i nstallation — r igging Provisions for forks have been included in the unit base frame. No other fork locations are approved.• Unit must be lifted by the four lifting holes located at the base frame corn...
Page 29 - and return duct openings.; Ba m
p rodUCt s peCifiCations p rodUCt s peCifiCations SS-CPC36-72 www.goodmanmfg.com 29 r oof C UrB i nstallation ( Cont .) Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association.Proper unit installation requires that ...
Page 30 - iring; ingle; arning
p rodUCt s peCifiCations p rodUCt s peCifiCations 30 www.goodmanmfg.com SS-CPC36-72 w iring d iagram — CpC036/48*1d (s ingle p hase , d ireCt d riVe ) H 1 RCCF T PU CONTROL BR C 2 T1 S T1 GR BK O 1 YL 4 BR 1 BR T1 BK 9 RD COMP R BR RCCF T2 3 C W2 T Y1 PLF 1 3 T YL/PK PU F BL 3 6 7 5 PU T3 G T2 COMPO...
Page 31 - hree
p rodUCt s peCifiCations p rodUCt s peCifiCations SS-CPC36-72 www.goodmanmfg.com 31 Wiring is subject t o chang e. Alw ay s re fer to the wiring diagr am or the unit for the mos t up-t o-da te wiring. ⚠ W arning High Volt ag e: Disc onn ect all po w er be for e ser vicing or in st alling this unit. ...
Page 36 - CCessories; Description; Downflow Economizer
p rodUCt s peCifiCations p rodUCt s peCifiCations 36 www.goodmanmfg.com SS-CPC36-72 Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2011 • Goodman Manufacturing Company, L.P. •...