Page 2 - INSTALLATION INSTRUCTIONS; IMPORTANT OPERATING CONDITIONS
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimizepulsation at drive elements, plumbing, connec-tions, and other system areas. The use of adampener with Giant Industries, Inc. pumps isoptional, although recommended by GiantIndustries, Inc. to further reduce system pulsa-tion. ...
Page 3 - P217A HORSEPOWER REQUIREMENTS; Specifications; *Pressure washer duty only
3 P217A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI*1725 1.7 1.2 1.8 2.4 3.0 3000 3.0 2.1 3.1 4.2 5.2 3200 3.2 2.2 3.3 4.4 5.5 3450 3.4 2.3 3.5 4.7 5.9 Specifications Model P217A NOTE: In order to drive the pump from the side opposite the presentshaft extension, simply remove...
Page 4 - P218A HORSEPOWER REQUIREMENTS
4 NOTE: In order to drive the pump from the side opposite the presentshaft extension, simply remove the valve casing from the crank-case and rotate the pumps 180 degrees to the desired position.Be certain to rotate the seal case (item #20) as well, so that theweep holes are down at the six o'clock p...
Page 5 - P219A HORSEPOWER REQUIREMENTS
5 Specifications Model P219A NOTE: In order to drive the pump from the side opposite the presentshaft extension, simply remove the valve casing from the crank-case and rotate the pumps 180 degrees to the desired position.Be certain to rotate the seal case (item #20) as well, so that theweep holes ar...
Page 6 - P220A HORSEPOWER REQUIREMENTS
6 Specifications Model P220A NOTE: In order to drive the pump from the side opposite the presentshaft extension, simply remove the valve casing from the crank-case and rotate the pumps 180 degrees to the desired position.Be certain to rotate the seal case (item #20) as well, so that theweep holes ar...
Page 7 - P221 HORSEPOWER REQUIREMENTS
7 Specifications Model P221A Volume ................................................................................................... Up to 2.21 GPMDischarge Pressure ................................................................................ Up to 2500 PSI * Inlet Pressure .....................
Page 8 - REQUIREMENTS
8 Specifications Model P223A Volume ................................................................................................... Up to 3.0 GPMDischarge Pressure ................................................................................ Up to 3000 PSI * Inlet Pressure ......................
Page 9 - P200A SERIES PARTS LIST
9 ITEM PART NO. DESCRIPTION QTY. 16A 06562 Plunger Base (P223 Only) 3 16B 08455 Plunger Pipe (Excluding P223) 3 16B 07778 Plunger Pipe (P223 Only) 3 16C 08456 Tension Screw 3 16D 07676 Copper Gasket 3 17 08442 Wrist Pin 3 18 07770 O-Ring 3 19 08356-0010 Oil Seal 3 20 08444 Seal Case (Excluding P223)...
Page 10 - Exploded View - P200A Series
Page 12 - REPAIR INSTRUCTIONS - P200A SERIES
12 NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly.This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elastomers) from cuttingand scoring. 1. With a 22mm socketwrench, remove the (3)discharge va...
Page 14 - PUMP SYSTEM MALFUNCTION
14 PUMP SYSTEM MALFUNCTION MALFUNCTION The Pressure and/orthe Delivery Drops Water in crankcase Noisy Operation Rough/PulsatingOperation withPressure Drop Pressure Drop atGun Excessive Leakage High CrankcaseTemperature CAUSE Worn packing sealsBroken valve springBelt slippageWorn or Damaged nozzleFou...
Page 15 - NOTES
Page 16 - GIANT INDUSTRIES LIMITED WARRANTY
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will never fail, period. If ...