Page 2 - NOTE; IMPORTANT SAFETY INSTRUCTIONS; SAFETY INFORMATION; POTENTIAL
PN# 37026500123 02/26/2010 REV. 1 2 OVERVIEW OF POTENTIAL HAZARDS READ THIS SAFETY INFORMATION Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since movingobjects, springs under tension, and electric motors can cause injuries, your saf...
Page 3 - SECTION
PN# 37026500123, 02/26/2010 REV. 1 3 TABLE OF CONTENTS OPENER FEATURES INTELLICODE ® Rolling Code Security System. An electronic rolling code system that enhances the security of the door opener by continuously changing the access code each time the remote control is used. The door opener responds t...
Page 4 - PRE-INSTALLATION CHECK LIST; This opener is designed for use with SECTIONAL doors only.; The door opener’s header bracket; you should consider; WA R N I N G; The outlet should be; WA R N I N G
PN# 37026500123 02/26/2010 REV. 1 6 To avoid damage to your door and/or opener, make sure you disable and/or remove any door locks, ropes, and/or cables(NOT door lift cables) prior to installing youropener . ( Refer to Section 1.) 4 PRE-INSTALLATION CHECK LIST FOR HELP-1.800.354.3643 OR WWW.GENIECOM...
Page 5 - TYPICAL SECTIONAL DOOR INSTALLATION
PN# 37026500123, 02/26/2010 REV. 1 5 TYPICAL SECTIONAL DOOR INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM TYPICAL SUPPORT BRACKET (NOT PROVIDED) EXTENSION SPRING OR TORSION SPRING SAFE-T-BEAM ® BRACES ADDED HEADER BRACKETMOUNTING BOARD POWER CORD (APPROX. 45 IN.) TO 120V GROUNDED OUTL...
Page 6 - Not Shown Full Size .
PN# 37026500123 02/26/2010 REV. 1 6 RECOMMENDED TOOLS FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 3/16" Drill Bit 1/4", 7/16", 3/8" and 1/2" Sockets Step ladder Drill Ratchet Carpenter’s level Pencil Tape measure Wire strippers Phillips screwdriver Adjustable wrench PARTS IDE...
Page 7 - DO NOT RETURN TO POINT OF PURCHASE.
PN# 37026500123 02/26/2010 REV. 1 FASTENERS - Shown Full size (See Parts List below for full description.) Lag screw - 5/16" x 2" Self-drilling Screw 1/4 -20 x 3/4" Hex Flange Nut 1/4 -20 Cotter pin Clevis pin 5/16" x 3/4" Hex Bolt - 5/16 -18 x 3/4" Hex Flange Nut 5/16 -18 Ra...
Page 8 - CHAIN
PN# 37026500123, 02/26/2010 REV. 1 8 1-PIECE RAIL HARDWARE ASSEMBLED VIEW FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 3-PIECE RAIL HARDWARE ASSEMBLED VIEW Tensioner Rail with chain Chain Chain Connector Release Knob Header Bracket Power Head Power Cord Carriage Assembly Clevis Pin, Long & Co...
Page 9 - OPENER ASSEMBLY; Note that some openers will; Remove the motor power head and place it on; CAUTION; Internal boxes; Box Label Example; IMPORTANT INSTALLATION INSTRUCTIONS; WARNING: To reduce the risk of severe injury or death:
PN# 37026500123, 02/26/2010 REV. 1 9 OPENER ASSEMBLY FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 1 NOTE: Three (3) piece rail assemblies are for a 7foot high door. Clear a workspace area to unpack and organize box and contents for assembly. 1. There are 4 boxes inside the carton. Each box is num...
Page 10 - Rail Assembly for CHAIN DRIVE OPENER; CHAIN DRIVE RAILS; Mount chain/belt to tensioner pulley; Wrap around tensioner pulley
10 FIG. 1-2 Split Rail sections . FIG. 1-3 Split Rail assembly . A B Chain Rail Center Rail End Rail Wire Tie(s) Rail Assembly for CHAIN DRIVE OPENER NOTE: For split rail clamps, nuts, and boltslocate Bag 0 from Box 1. 3. Remove the two rail sections that are not connected to the chain and place the...
Page 11 - POWER HEAD & RAIL ASSEMBLY; Assembly for CHAIN DRIVE OPENER; The chain adjustment nut is; Chain adjustment; Disable garage door lock; Belt adjustment; Assembly for BELT DRIVE OPENER; The belt adjustment nut is located in; C A U T I O N
POWER HEAD & RAIL ASSEMBLY Assembly for CHAIN DRIVE OPENER NOTE: Handle carefully! Drive chain can slide outof rail. NOTE: For power head and rail assembly locateBag 1 from Box 1. NOTE: Copy serial number from power headframe and record it on warranty page. 1. Attach rail assembly to power head ...
Page 12 - OPENER INSTALLATION; Finding header bracket mounting location; Do NOT move door spring!; WARNING
12 PN# 37026500123 02/26/2010 REV. 1 FIG. 2-2 Finding highest point of travel . OPENER INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 2 HEADER AND DOOR MOUNTING BRACKETS: 1. Finding header bracket mounting location . • Close garage door. – Use a pencil and level. a) Mark center of gara...
Page 13 - Position assembly and align; HEADER BRACKET; Mounting Straps; Mounting the power head; Attach angle iron to beams; FIG. 2-5 Rail mounting to header bracket
MOUNTING THE OPENER: 1. Getting started . • Position assembled rail on wall next to header bracket (Fig. 2-4) . – Place material on floor under power head to protect from scratching. (A box, stool, or similar device may be needed to clear a torsion spring.) NOTE: For header bracket pins locate Bag 2...
Page 14 - INSTALL DOOR ARMS; short clevis pin & cotter pin
14 PN# 37026500123 02/26/2010 REV. 1 DOOR BRACKET: NOTE: For door bracket and bolts locate Bag 4from Box 2. 1. Finding door bracket mounting location . • Door bracket is mounted as high on door as possible along vertical centerline and NO LOWER THAN top set of rollers (Fig. 2-7) . 2. Mounting the do...
Page 15 - WALL CONSOLE INSTALLATION; Splitting and stripping; White
PN# 37026500123 02/26/2010 REV. 1 NOTE: Wall console will not operate until limitsare set. NOTE: For Wall Console, wire and insulated staples locate Bags 6 and 7 from Box 2. 1. Wall Console location. Wall Console location should be in direct sight of door. It should be at least five feet (5') ab...
Page 16 - Do NOT install rear cover yet.; Mounting Wall Console.; Insulated; Mounting Entrapment warning label; Independent Light Control; Controls door opener lights from inside garage; Vacation Locking Switch; Open and closes door from
PN# 37026500123 02/26/2010 REV. 1 16 3. Securely fasten wires. Securely fasten wires to ceiling and wall using insulated staples provided. – Use insulated staples. – Staples should be snug only. If rear cover is attached to power head, remove it. On power head: – Route Wall Console wires throu...
Page 17 - SYSTEM INSTALLATION; System is; Dashed Line = striped wire
17 PN# 37026500123, 02/26/2010 REV. 1 SAFE-T-BEAM ® SYSTEM INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 4 NOTE: The opener will not close the door automatically unless the Safe-T-Beam ® System is installed. NOTE: For Safe-T-Beam®, screws, wire, and insulated staples locate items and ...
Page 18 - wire to power head wire; alignment check must be; methods
PN# 37026500123 02/26/2010 REV. 1 18 3b. Wiring (pre-wired) . Route wire from wall to Safe-T-Beam ® sensors (Fig. 4-5b) . Splice pre-wiring to shortened sensor wire, match wire pairs dash-to-dash (striped-to- striped) and plain-to-plain (white-to-white) . - Trim sensor wire to approximately one ...
Page 19 - CONNECTING TO POWER; grounding; Check local building codes; alignment; INFRARED PROTECTION FUNCTION; before; ƁƁ; Remove motor cover; WITH PERMANENT WIRING:; Instructions for Electrician.; Motor Cover Screws
PN# 37026500123, 02/26/2010 REV. 1 19 CONNECTING TO POWER FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 5 Plug the opener into a properly grounded electrical outlet (Fig. 5-1). To reduce the risk of electrical shock, this equipment has a grounded type plug that includes a third ( grounding ) pin...
Page 20 - DOOR LIMITS; Limit controls; Engage Chain/Belt Connector to Carriage
PN# 37026500123 02/26/2010 REV. 1 20 DOOR LIMITS FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 6 The OPEN (UP) and CLOSE (DOWN) door positionsare controlled by making the adjustments on thepanel located on the bottom of the power head. Theadjustments that can be made are: • Close Travel Limit, • O...
Page 21 - DOOR; Engage/Disengage Carriage Lock; CARRIAGE LOCK; opener power head; remove; Emergency release cable to carriage; Keyed Emergency Release Operation Instructions
21 UNLOCK DOOR LOCK TO RECONNECT PULL TOWARD DOOR TO RELEASE PULL TOWARD THE OPENER FIG. 6-3 Engage/Disengage Carriage Lock . CARRIAGE LOCK The Carriage Lock can be manually engaged or disengaged. • To disengage Carriage Lock – Pull handle downward opener power head . • To engage Carriage Lock – Pul...
Page 22 - x 4 under center of door opening.; CONTACT REVERSE TEST; wise; OPEN; Force Control Adjustment
PN# 37026500123 02/26/2010 REV. 1 22 FIG. 6-6 2 x 4 under center of door opening. CONTACT REVERSE TEST The force adjustments and limit switch settingsMUST BE COMPLETED before testing. 1. Testing . • Open garage door using Wall Control. – Place a 2" x 4" board (laid flat) under center of gara...
Page 23 - FCC and IC CERTIFIED; Learn code button and LED; PROGRAMMING REMOTE CONTROLS; LOST OR STOLEN REMOTE; Your door opener will no
PN# 37026500123, 02/26/2010 REV. 1 23 FCC and IC CERTIFIED FIG. 7-1 Learn code button and LED SET SET OPEN FORCE CLOSE CODE LEARN LIMIT MANUAL Open Travel Limit Open Set Limit Button Close Travel Limit Close Set Limit Button Down Force Control Adjustment Up Force Control Adjustment Learn Code Button...
Page 24 - REMOTE CONTROL; BATTERY REPLACEMENT AND VISOR CLIP INSTALLATION; Battery replacement; Alkaline; LIGHT BULB / LENS INSTALLATION; heavy duty service
REMOTE CONTROL BATTERY REPLACEMENT AND VISOR CLIP INSTALLATION 8 FIG. 8-1 Open battery cover . 1. Battery replacement . • To open, gently push straight out on battery cover lock tab as shown. (Fig. 8-1) . • Slide open battery cover. – Remove old battery. • Make sure new battery is facing proper dire...
Page 25 - If you have any questions, please do not hesitate to contact Genie; IMPORTANT SAFETY INSTRUCTIONS; SAVE THESE INSTRUCTIONS.; To reduce the risk of severe injury or death:; MAINTENANCE
PN# 37026500123 02/26/2010 REV. 1 25 Use Wall Control supplied with opener. Any other Wall Control can causethe opener to operate unexpectedly. WARNING If you have any questions, please do not hesitate to contact Genie ® customer service at: 1.800.354.3643 IMPORTANT SAFETY INSTRUCTIONS 1. READ AND F...
Page 26 - CIRCUIT WIRING DIAGRAM; POWER CORD; CORDON DE SECTEUR; PRIMARY; SECONDARY; L’ouverture du couvercle peut entraîner des chocs électriques.; CHOQUE ELÉCTRICO
PN# 37026500123 02/26/2010 REV. 1 26 CIRCUIT WIRING DIAGRAM FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 1 2 3 4 1 2 3 1 2 POWER CORD CORDON DE SECTEUR CABLE ELÉCTRICO TERMINAL BLOCK BORNE BLOQUE DE TERMINALES WHITE BLANC BLANCO BLACK NOIR NEGRO GREEN VERT VERDE SURGE PROTECTOR (MOV) LIMITEUR DE ...
Page 27 - TROUBLESHOOTING GUIDE -; OPERATION; PROBLEM; OR
PN# 37026500123, 02/26/2010 REV. 1 27 TROUBLESHOOTING GUIDE - OPERATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM PROBLEM WHAT TO DO Opener does NOT runfrom Wall Console. Check power source. – Plug a lamp into outlet used for power head. If lamp works, power source is OK. – If not, check fus...
Page 28 - POWER HEAD LED; Power head LED; Possible Problem; Red LED
PN# 37026500123, 02/26/2010 REV. 1 TROUBLESHOOTING GUIDE - POWER HEAD LED FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM Power head LED Possible Problem Solution Red LED showing Green LED showing OFF OFF Normal operation None required Continuous ON Programming incomplete Complete programming 1 ...
Page 29 - TRANSMITTER COMPLIANCE STATEMENT
PN# 37026500123 02/26/2010 REV. 1 29 Transmitters comply with all United States and Canadian legal requirements as of the date of manufacture. No warranty is madethat they comply with all legal requirements of any other jurisdiction. If transmitters are to be used in another country, the importermus...
Page 30 - Limited Warranty
GMI Holdings, Inc. d/b/a The Genie Company ("Seller") warrants to the original purchaser of the below identified opener, Model 2022/2024/2042 (“Product”), subject to all of the terms and conditions hereof, that the Product and all components thereof will be free from defects in materials and...