Page 2 - NOTE; IMPORTANT SAFETY INSTRUCTIONS; SAFETY INFORMATION; POTENTIAL
PN# 37026500123 05/15/2009 2 OVERVIEW OF POTENTIAL HAZARDS READ THIS SAFETY INFORMATION Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety an...
Page 3 - SECTION; OPENER ASSEMBLY
PN# 37026500123 05/15/2009 3 TABLE OF CONTENTS OPENER FEATURES INTELLICODE ® Rolling Code Security System. An electronic rolling code system that enhances the security of the door opener by continuously changing the access code each time the remote control is used. The door opener responds to each n...
Page 4 - PRE-INSTALLATION CHECK LIST; This opener is designed for use with SECTIONAL doors only.; NOTE: Mounting brackets must be installed; WARNING
PN# 37026500123 05/15/2009 6 To avoid damage to your door and/or opener, make sure you disable and/or remove any door locks, ropes, and/or cables (NOT door lift cables) prior to installing your opener . ( Refer to Section 1.) 4 PRE-INSTALLATION CHECK LIST FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY....
Page 5 - TYPICAL SECTIONAL DOOR INSTALLATION; To reduce the risk of injury to persons or
PN# 37026500123 05/15/2009 5 TYPICAL SECTIONAL DOOR INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM TYPICAL SUPPORT BRACKET (NOT PROVIDED) EXTENSION SPRING OR TORSION SPRING SAFE-T-BEAM ® SENSORS BRACES ADDED HEADER BRACKET MOUNTING BOARD POWER CORD (APPROX. 45 IN.) TO 120V GROUNDED OUT...
Page 6 - Not Shown Full Size .
PN# 37026500123 05/15/2009 6 RECOMMENDED TOOLS FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 3/16" Drill Bit 1/4", 7/16", 3/8" and 1/2" Sockets Step ladder Drill Ratchet Carpenter’s level Pencil Tape measure Wire strippers Phillips screwdriver Adjustable wrench PARTS IDENTIFICA...
Page 7 - DO NOT RETURN TO POINT OF PURCHASE.
PN# 37026500123 05/15/2009 FASTENERS - Shown Full size (See Parts List below for full description.) Lag screw - 5/16" x 2" Self-drilling Screw 1/4 -20 x 3/4" Hex Flange Nut 1/4 -20 Cotter pin Clevis pin 5/16" x 3/4" Hex Bolt - 5/16 -18 x 3/4" Hex Flange Nut 5/16 -18 Rail Clam...
Page 8 - CHAIN
PN# 37026500123 05/15/2009 8 1-PIECE RAIL HARDWARE ASSEMBLED VIEW FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 3-PIECE RAIL HARDWARE ASSEMBLED VIEW Tensioner Rail with chain Chain Carriage Slide Release Knob Header Bracket Power Head Power Cord Clevis Pin, Long & Cotter Pin NO TE Som e d oors...
Page 9 - foot high sectional door.; Carefully remove the three; CAUTION; questions or do not understand an instruction, call The; IMPORTANT INSTALLATION INSTRUCTIONS
PN# 37026500123 05/15/2009 9 OPENER ASSEMBLY FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 1 NOTE: Three (3) piece rail assemblies are for a 7 foot high sectional door. Clear a workspace area to unpack and organize box and contents for assembly. 1. There are 4 boxes inside the carton. Each box is ...
Page 10 - Rail Assembly for CHAIN DRIVE OPENER; Rail Assembly for BELT DRIVE OPENER; locate Bag 0 from Box 1.; CHAIN DRIVE RAILS
10 FIG. 1-2 Split Rail sections . FIG. 1-3 Split Rail assembly . A B Chain Rail Center Rail End Rail Wire Tie(s) Rail Assembly for CHAIN DRIVE OPENER NOTE: For split rail clamps, nuts, and bolts locate Bag 0 from Box 1. 3. Remove the two rail sections that are not connected to the chain and place th...
Page 11 - NOTE: For power head and rail assembly locate
POWER HEAD & RAIL ASSEMBLY Assembly for CHAIN DRIVE OPENER NOTE: Handle carefully! Drive chain can slide out of rail.NOTE: For power head and rail assembly locate Bag 1 from Box 1.NOTE: Copy serial number from power head frame and record it on warranty page. 1. Attach rail assembly to power head...
Page 12 - Finding header bracket mounting location; Do NOT move door spring!
12 PN# 37026500123 05/15/2009 FIG. 2-2 Finding highest point of travel . OPENER INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 2 HEADER AND DOOR MOUNTING BRACKETS: 1. Finding header bracket mounting location . • Close garage door. – Use a pencil and level. a) Mark center of garage door...
Page 13 - NOTE: For header bracket pins locate Bag 2 from; Mounting the assembly; NOTE: Before final attachment to ceiling, insure; finished; NOTE: Refer to your local building codes for; DO NOT PLUG OPENER IN YET!; HEADER BRACKET; Mounting Straps; ANGLE IRON ON FINISHED CEILING; Attach angle iron to beams; not needed; DRYWALL; FIG. 2-5 Rail mounting to header bracket
MOUNTING THE OPENER: 1. Getting started . • Position assembled rail on wall next to header bracket (Fig. 2-4) . – Place material on floor under power head to protect from scratching. (A box, stool, or similar device may be needed to clear a torsion spring.) NOTE: For header bracket pins locate Bag 2...
Page 14 - INSTALL DOOR ARMS; NOTE: For door arm nuts and bolts, clevis and; centerline; short clevis pin & cotter pin
14 PN# 37026500123 05/15/2009 DOOR BRACKET: NOTE: For door bracket and bolts locate Bag 4 from Box 2. 1. Finding door bracket mounting location . • Door bracket is mounted as high on door as possible along vertical centerline and NO LOWER THAN top set of rollers (Fig. 2-7) . 2. Mounting the door bra...
Page 15 - WALL CONTROL INSTALLATION; This is an example of wire routing; White
PN# 37026500123 05/15/2009 NOTE: For Wall Control, wire and insulated staples locate Bags 6 and 7 from Box 2. 1. Wall Control location. • Wall Control location should be in direct sight of door. • It should be at least five feet (5') above floor to prevent small children from operating door. • It mu...
Page 16 - Do NOT install rear cover yet.; Insulated; FIG. 3-5 Mounting Entrapment warning label; Independent Light Control; Controls door opener lights from inside garage; Vacation Locking Switch; – LOCK disables controls after; Open and closes door from
PN# 37026500123 05/15/2009 16 3. Securely fasten wires. • Securely fasten wires to ceiling and wall using insulated staples provided. – Use insulated staples. – Staples should be snug only. • If rear cover is attached to power head, remove it. • On power head: – Route Wall Control wires through wire...
Page 17 - SYSTEM INSTALLATION; Dashed Line = striped wire
PN# 37026500123 05/15/2009 17 SAFE-T-BEAM ® SYSTEM INSTALLATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 4 NOTE: The opener will not close the door automatically unless the Safe-T-Beam ® System is installed.NOTE: For Sensors, screws, wire, and insulated staples locate items and Bag 8 from Box...
Page 18 - wire to power head wire; alignment check must be; methods
PN# 37026500123 05/15/2009 18 3b. Wiring (pre-wired) . • Route wire from wall to Safe-T-Beam ® sensors (Fig. 4-5b) . • Splice pre-wiring to shortened sensor wire, match wire pairs dash-to-dash (striped-to- striped) and plain-to-plain (white-to-white) . - Trim sensor wire to approximately one foot (1...
Page 19 - CONNECTING TO POWER; grounding; alignment; INFRARED PROTECTION FUNCTION; NOTE: The Genie Company is not responsible for; Motor Cover Screws
PN# 37026500123 05/15/2009 19 CONNECTING TO POWER FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 5 Plug the opener into a properly grounded electrical outlet (Fig. 5-1). • To reduce the risk of electrical shock, this equipment has a grounded type plug that includes a third ( grounding ) pin. This p...
Page 20 - DOOR LIMITS; Limit Controls location; B) CLOSE TRAVEL LIMIT
PN# 37026500123 05/15/2009 20 DOOR LIMITS FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 6 The OPEN (UP) and CLOSE (DOWN) door positions are controlled by making the adjustments on the panel located on the bottom of the power head. The adjustments that can be made are: • Close Travel Limit, • Open ...
Page 21 - DOOR; CARRIAGE LOCK; wise; OPEN
21 UNLOCK DOOR LOCK TO RECONNECT PULL TOWARD DOOR TO RELEASE PULL TOWARD THE OPENER FIG. 6-3 Engage/Disengage Carriage Lock . CARRIAGE LOCK The Carriage Lock can be manually engaged or disengaged. • To disengage Carriage Lock – Pull handle downward opener power head . • To engage Carriage Lock – Pul...
Page 22 - CONTACT REVERSE TEST; The force adjustments and limit switch settings; NOTE: The opener will not close the door
PN# 37026500123 05/15/2009 22 FIG. 6-5 2 x 4 under center of door opening. CONTACT REVERSE TEST The force adjustments and limit switch settings MUST BE COMPLETED before testing.1. Testing . • Open garage door using Wall Control. – Place a 2" x 4" board (laid flat) under center of garage door...
Page 23 - FCC and IC CERTIFIED; PROGRAMMING REMOTE CONTROLS; LOST OR STOLEN REMOTE; Homelink; Limit controls location
PN# 37026500123 05/15/2009 23 FCC and IC CERTIFIED FIG. 7-1 Learn code button and LED SET SET OPEN FORCE CLOSE CODE LEARN LIMIT MANUAL Open Travel Limit Open Set Limit Button Close Travel Limit Close Set Limit Button Down Force Control Adjustment Up Force Control Adjustment Learn Code Button LED Ind...
Page 24 - REMOTE CONTROL; BATTERY REPLACEMENT AND VISOR CLIP INSTALLATION; Battery replacement; Alkaline; LIGHT BULB / LENS INSTALLATION; heavy duty service
REMOTE CONTROL BATTERY REPLACEMENT AND VISOR CLIP INSTALLATION 8 FIG. 8-1 Open battery cover . 1. Battery replacement . • To open, gently push straight out on battery cover lock tab as shown. (Fig. 8-1) . • Slide open battery cover. – Remove old battery. • Make sure new battery is facing proper dire...
Page 25 - the opener to operate unexpectedly.; If you have any questions, please do not hesitate to contact Genie; IMPORTANT SAFETY INSTRUCTIONS; SAVE THESE INSTRUCTIONS.; To reduce the risk of severe injury or death:; MAINTENANCE
PN# 37026500123 05/15/2009 25 Use Wall Control supplied with opener. Any other Wall Control can cause the opener to operate unexpectedly. WARNING If you have any questions, please do not hesitate to contact Genie ® customer service at: 1.800.354.3643 IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ...
Page 26 - CIRCUIT WIRING DIAGRAM; POWER CORD; CORDON DE SECTEUR; PRIMARY; SECONDARY; Opening Cover May Cause Electric Shock.; Abrir la tapa puede causar choques eléctricos.; Disconnect power from opener prior to removing cover.; ELECTRICAL SHOCK; CHOQUE ELÉCTRICO
PN# 37026500123 05/15/2009 26 CIRCUIT WIRING DIAGRAM FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 1 2 3 4 5 6 1 2 3 4 1 2 3 1 2 POWER CORD CORDON DE SECTEUR CABLE ELÉCTRICO TERMINAL BLOCK BORNE BLOQUE DE TERMINALES WHITE BLANC BLANCO BLACK NOIR NEGRO GREEN VERT VERDE SURGE PROTECTOR (MOV) LIMITEU...
Page 27 - TROUBLESHOOTING GUIDE -; OPERATION; PROBLEM
PN# 37026500123 05/15/2009 27 TROUBLESHOOTING GUIDE - OPERATION FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM PROBLEM WHAT TO DO Opener does NOT run from Wall Control. • Check power source. – Plug a lamp into outlet used for power head. If lamp works, power source is OK. – If not, check fuse or ci...
Page 28 - POWER HEAD LED; Power head LED; Possible Problem; Red LED
PN# 37026500123 05/15/2009 TROUBLESHOOTING GUIDE - POWER HEAD LED FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM Power head LED Possible Problem Solution Red LED showing Green LED showing OFF OFF Normal operation None required Continuous ON • Programming incomplete • Complete programming 1 BLINK, P...
Page 29 - TRANSMITTER COMPLIANCE STATEMENT
PN# 37026500123 05/15/2009 29 Transmitters comply with all United States and Canadian legal requirements as of the date of manufacture. No warranty is made that they comply with all legal requirements of any other jurisdiction. If transmitters are to be used in another country, the importer must det...
Page 30 - Limited Warranty
GMI Holdings, Inc. d/b/a The Genie Company ("Seller") warrants to the original purchaser of the below identified opener, Model 2022/2024/2042 (“Product”), subject to all of the terms and conditions hereof, that the Product and all components thereof will be free from defects in materials and...