Page 2 - application & engineering data; ENGINE SPECIFICATIONS: 48kW; Quietsource

2 of 9 22 • 27 • 36 • 48 kW application & engineering data GENERATOR SPECIFICATIONS Type Synchronous Rotor Insulation Class H (22 & 27 kW) or F (36 & 48 kW) Stator Insulation Class H Telephone Interference Factor (TIF) <50 Alternator Output Leads 1-Phase 4 wire Alternator Output Leads...

Page 3 - operating data; kW LPG; SURGE CAPACITY IN AMPS; Natural Gas; Exercise cycle; Fuel pipe must be sized for full load.

3 of 9 22 • 27 • 36 • 48 kW operating data GENERATOR OUTPUT VOLTAGE/kW - 60Hz kW LPG Amp LPG kW Nat. Gas Amp Nat. Gas CB Size (Both) QT022 120/240 V, 1Ø, 1.0 pf 22 92 22 92 100 120/208 V, 3Ø, 0.8 pf 22 76 22 76 80 120/240 V, 3Ø, 0.8 pf 22 66 22 66 80 QT027 120/240 V, 1Ø, 1.0 pf 27 113 25 104 125 120...

Page 5 - available accessories; Product

5 of 9 22 • 27 • 36 • 48 kW available accessories Quietsource ® Series Model # Product Description 005630-0 - 22, 27 & 36 kW005632-0 - 48 kW Cold Weather Kit If the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to maintain optimal battery temperature. Kit consists of...