Page 2 - Application & Engineering Data

Application & Engineering Data Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with B...

Page 3 - OPERATING DATA; (inlet air including alternator and combustion air); Generac

OPERATING DATA KW RATING (LP/NG) 22/22 ENGINE SIZE 2.4 Liter Inline 4 GENERATOR OUTPUT VOLTAGE/KW - 60Hz KW AMP CB Size 120/240V, 1-phase, 1.0 pf120/208V, 3-phase, 0.8 pf120/240V, 3-phase, 0.8 pf 222222 927666 100 8080 ENGINE FUEL CONSUMPTION (Natural Gas) (Propane) Exercise cycle25% of rated load50...

Page 4 - INTERCONNECTIONS; NEXUSTM CONTROL FEATURES; LIQUID-COOLED INSTALLATION

INTERCONNECTIONS NEXUS™ CONTROL FEATURES 2-Line Plain Text LCD Display Simple user interface for ease of operation Mode Switch -Auto Automatic Start on Utility failure. 7 day exerciser -Off Stops unit. Power is removed. Control and charger still operate. -Manual/Test (start) Start with starter contr...