Page 2 - or to prevent property damage, personal injury, or loss of life.; DO NOT use equipment certified for R22; Replacing an existing unit?; SAFETY PRECAUTIONS; SAFETY INFORMATION; WARNING
2 IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. ■ This Zoneline must be properly installed in...
Page 3 - Avant son utilisation, ce climatiseur Zoneline doit; N’UTILISEZ PAS d’équipements; Vous remplacez un climatiseur existant?; MESURES DE SÉCURITÉ; DANGER; AVERTISSEMENT
CONSIGNES DE SÉCURITÉ IMPORTANTES LISEZ TOUTES LES INSTRUCTIONS AVANT L’UTILISATION Pour votre sécurité, veuillez observer les consignes de ce manuel afin de réduire le risque d’incendie, d’explosion, de choc électrique, de dommages à la propriété ou de blessures, graves ou fatales. ■ Avant son util...
Page 4 - Antes de iniciar su uso, el acondicionador de aire; ¿Desea reemplazar una unidad ya instalada?; PRECAUCIONES DE SEGURIDAD; INFORMACIÓN DE SEGURIDAD; ADVERTENCIA
INFORMACIÓN IMPORTANTE DE SEGURIDAD LEA TODAS LAS INSTRUCCIONES ANTES DE USAR Para su seguridad, se debe seguir la información de este manual para minimizar el riesgo de incendio o explosión, descargas eléctricas, o para evitar daños a la propiedad, lesiones personales o la muerte. ■ Antes de inicia...
Page 5 - About Your Heat Pump; About the controls on your Zoneline; Temp Control; Control Lock Out; Quick Heat Recovery
About Your Heat Pump (AZ65 only) Heat pumps can save money by removing heat from the outside DLU³HYHQZKHQWKHRXWVLGHWHPSHUDWXUHLVEHORZIUHH]LQJ³DQG releasing that heat indoors.To get the best energy performance from your heat pump, don’t change the room thermostat by more than one degree at one time. ...
Page 6 - Air Direction; Other features of your Zoneline; To Remove the Room Front
Ventilation Control* NOTE: Two shipping screws must be removed from the vent door before use. See the Installation Instructions in the back of this manual. If you do not plan to use the ventilation feature, leave the two screws in place. The ventilation control lever is located at the lower left sid...
Page 7 - Auxiliary controls on your Zoneline
Auxiliary controls on your Zoneline $X[LOLDU\&RQWUROV³$X[6HW%XWWRQ While the unit is preset to what most customers prefer, the auxiliary controls located behind the room cover, below the control panel.Remove the room cover. See the To Remove the Room Cover section. If the owner modifies the auxi...
Page 8 - Constant ON Fan; Freeze Sentinel/Heat Sentinel
8 Auxiliary controls on your Zoneline Constant ON Fan Press MODE until a 4 appears in the first digit of the display to set the fan to run continuously at high speed - even if the unit is turned off. Press the - pad for OFF “ “ or the + pad for ON “ .” This is shown in the second digit of the displa...
Page 9 - Duct Mode; Use Wall Thermostat
Auxiliary controls on your Zoneline Duct Mode This setting is used when the unit is installed with a duct adapter kit. If the unit is ducted, the Duct Mode needs to be set to ON. This increases the fan speed to ensure proper circulation.Press MODE until a 7 appears in the first digit of the display....
Page 11 - Remote Thermostat
External Fan (Field Installed) When connected, an auxiliary or external fan can be controlled with the indoor fan motor on the Zoneline. Connections provide 24 V AC to energize a remote relay.The RAKCDC accessory must be used when using an external fan. Central Desk Control (Field Supplied) The Cent...
Page 12 - Operating Instructions; Base Pan; Room Cover and Case; Care and cleaning
Operating Instructions Base Pan In some installations, dirt or other debris may be blown into the unit from the outside and settle in the base pan (the bottom of the unit). In some areas of the United States, a naturally occurring “gel-like” or “slime-like” substance may be seen in the base pan.Chec...
Page 13 - Air Filters; Ventilation Filter
To maintain optimum performance, clean the filters at least every 30 days. Air Filters FRONT FRONT 'LUW\ILOWHU³1HHGVFOHDQLQJ &ORJJHGILOWHU³*UHDWO\ reduces cooling, heating and airflow. Turn the Zoneline off before cleaning. The most important thing you can do to maintain the Zoneline is to clean...
Page 14 - BEFORE YOU BEGIN; Installation Instructions Zoneline Air Conditioners; IMPORTANT –; Note to Installer –; or; IMPORTANT ELECTRICAL; TOOLS YOU WILL NEED; AIR CONDITIONER BREAK-IN PERIOD; CAUTION; ATTENTION; PRECAUCIÓN
BEFORE YOU BEGIN Installation Instructions Zoneline Air Conditioners Read these instructions completely and carefully. • IMPORTANT – Save these instructions for local inspector’s use. • IMPORTANT – Observe all governing codes and ordinances. • Note to Installer – Be sure to leave these instructions ...
Page 15 - Installation Instructions; Use the correct wall case; REPLACING AN EXISTING UNIT
Installation Instructions Use the correct wall case This unit is designed to be installed in a GE plastic or insulated metal wall case. This minimizes condensation from forming on the room side of the case. NOTE: There are several extra holes in the unit side flanges for installation in wall cases o...
Page 17 - INSTALLATION
Installation Instructions 265 VOLT ELECTRICAL CONNECTION OPTIONS Connection of this 265 V AC product to a branch circuit MUST be done by direct connection in accordance with the National Electrical Code. Plugging this unit into a building-mounted exposed receptacle is not permitted by code. These mo...
Page 18 - Power Cord Connections
Installation Instructions POWER CONNECTION CHART Power Cord Connections Direct Connections 230/208 Volt Power Supply Kits with Current Leakage Detection Device (1) Wall Plug &RQ¿JHUDWLRQ Circuit Protective Device Heater Wattage @ 230/208 Volts RAK315P/SPRAK320P/SPRAK330P/SP TandemPerpendicularLa...
Page 21 - External Drain
Installation Instructions 237,21$/³'5$,1.,7,167$//$7,21 Dry Air 25 Series models are designed to improve dehumidification by 25%. Since more moisture will be removed from the air, there is a greater possibility that water will drip from the wall case than with a standard unit. To prevent this water ...
Page 22 - Before you call for service; Troubleshooting Tips
Before you call for service Troubleshooting Tips Save time and money! Review the charts on the following pages first and you may not need to call for service. Problem Possible Causes What To Do Zoneline does The unit is • Make sure the Zoneline plug is pushed completely not start unplugged. into the...
Page 24 - Normal Operating Sounds; Things that are normal; Delay
Normal Operating Sounds You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. You may hear relays click when the controls cycle on and off or are adju...
Page 25 - Product Registration
25 Product Registration Complete and mail your Consumer Production Registration today. Have the peace of mind of knowing we can contact you in the unlikely event of a safety PRGL¿FDWLRQ After mailing the registration below, store this document in a safe place. It contains infor- mation you will need...
Page 26 - Please place in envelope and mail to:
Please place in envelope and mail to: Please place in envelope and mail to:Veuillez mettre dans une enveloppe et envoyez à : 26 Product Registration
Page 27 - Zoneline Warranty; What GE Will Not Cover:; consumer affairs office or your state’s Attorney General.
Zoneline Warranty ■ Service trips to your site to teach you how to use the product. ■ Improper installation, delivery or maintenance. If you have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are respons...
Page 28 - Consumer Support
Printed in USA Consumer Support GE Appliances Website GEAppliances.com Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts or even sche...