2 Installation, Operation and Maintenance Instructions INSTALLATION 3. Proper clearance from combustible materials must be maintained at all times. The minimum clearances are as follows: Minimum Clearance from Combustibles:Side 500 mm Rear 500 mm Ceiling 500 mm Combustible materials are considered t...
Page 3 - IMPORTANT; POL CYLINDER CONNECTION DEVICE
3 7. The hose must be protected from contact with hot or sharp surfaces both during use and while in storage. The hose assembly should be visually inspected prior to each use of the heater. If excessive abrasion or wear is evident, or the hose is cut, it must be replaced prior to operating the heate...
Page 4 - PATIO HEATER - For Outdoor Use Only; Minimum Clearance from Combustible Surfaces*:; Cylinder cover
4 PATIO HEATER - For Outdoor Use Only Minimum Clearance from Combustible Surfaces*: *Combustible materials are considered to be wood, compressed paper, plant fibres, plastic or other materials that are capable of being ignited and burned. 2130mm Hose c onnec tion poin t 1600mm 460mm Cylinder cover B...
Page 6 - Tools Required; Slide the cylinder cover over the post.; PATIO HEATER ASSEMBLY
Tools Required Phillips head screwdriver2 Adjustable spannersNote: Remove any transit protection material STEP 1 Secure the post onto the post support with 6 screws, feed the hose up through the post and temporarily secure the end with tape to the post top. STEP 2 Slide the cylinder cover over the p...
Page 7 - TEST FIRING HEATER; DO NOT use a match to test for gas leaks.; TROUBLE SHOOTING; Problem; LIGHTING INSTRUCTIONS
TEST FIRING HEATER Test fire heater, following the lighting instructions on heater post. Leak test all gas connections with soapy water. Soap bubbles indicate gas leakage. DO NOT use a match to test for gas leaks. WARNING: White smoke may appear around the radiant head during the first minute of the...
Page 8 - SAFE APPLIANCE LOCATIONS; For any queries or assistance call:; Customer Service; Hours of Operation: Mon to Fri 8am - 5pm EST
The following figures are diagrammatic representations of outdoor areas. Rectangular areas have been used in these figures – the same principles apply to any other shaped area. SAFE APPLIANCE LOCATIONS This appliance shall only be used in an above ground open-air situation with natural ventilation, ...