Page 2 - P S - P R O H T - P O W E R C O N D I T I O N E R / S E Q U E N C E R; F E AT U R E S; Ten; I N T R O D U C T I O N; Congratulations on your pur-; DESCRIPTION
P S - P R O H T - P O W E R C O N D I T I O N E R / S E Q U E N C E R F E AT U R E S 20 amp (2400 watt) rating handles even the largest power amplifiers. Multiple levels of protection compo-nents can safely absorb large voltage spikes and provide highly effective RFI / EMI filtering. Extreme Volt...
Page 4 - ON OR OFF SEQUENCING; POWER CONDITIONING FEATURES
P S - P R O H T - P O W E R C O N D I T I O N E R / S E Q U E N C E R tions, if the voltage falls below 80 volts or rises above 140 volts. This feature is called “Extreme Voltage Shutdown.” See pages 5-6 for more information on the various protection features’ indicator lights.Despite its many prote...
Page 5 - Maintained Mode
P S - P R O H T - P O W E R C O N D I T I O N E R / S E Q U E N C E R switches and push-on/push-off button switches, (including the Furman RS-1 key lock switch), stay open until switched, and then remain closed until switched again. Momentary switches, usually push-button types like the Furman RS-2 ...
Page 6 - FRONT PANEL
P S - P R O H T - P O W E R C O N D I T I O N E R / S E Q U E N C E R START ON/OFF SEQUENCE: This pushbutton switch is used only when the key lock switch is in REM posi- tion and the PS-PRO HT is in Momentary Mode. It then acts the same as any other remote momentary switch that may be connected to t...
Page 7 - REAR PANEL
P S - P R O H T - P O W E R C O N D I T I O N E R / S E Q U E N C E R OFF sequence. In the REM position, the PS-PRO HT will accept on/off commands from a remote switch or switches that may be connected to the rear panel terminals.CIRCUIT BREAKER: The overall capacity of the PS- PRO HT is 20 amps. If ...
Page 8 - Multiple Units; Momentary Mode
P S - P R O H T - P O W E R C O N D I T I O N E R / S E Q U E N C E R The front-panel key lock switch is not the primary means of control in the momentary mode and should normally be left in REM. It may be a useful secondary means of control in the rare case of having several PS-PRO HT’s in parallel...
Page 9 - STATUS Terminal; Effects of Lightning
P S - P R O H T - P O W E R C O N D I T I O N E R / S E Q U E N C E R other units.The STATUS lines work the same in either mode. Each reflects the true state of the unit’s outlets and is affected by both the “memorized” state and by the key lock switch. A separate LED must be used to indicate the sta...
Page 10 - Three Year Limited Warranty; Service
P S - P R O H T - P O W E R C O N D I T I O N E R / S E Q U E N C E R 9 Three Year Limited Warranty The Furman PS-PRO HT is protected by a limited three year warranty, covering defects in materials and workmanship, provided that the registration card is filled out and returned by the customer. Otherw...
Page 11 - PS-PRO HT SPECIFICATIONS
P S - P R O H T - P O W E R C O N D I T I O N E R / S E Q U E N C E R Current rating: 20 Amps (2400 Watts at 120 VAC) Input Voltage: 85 to 264 VAC without damage Mains Wiring analyzer: Detects one normal mode and five fault modesDelay Intervals: Total elapsed ON or OFF delay time adjustable from 1-60...