Page 2 - 50 V Receptacles and Fuse Types
2 P E R F O R M A N C E D A T A : Cooling Btuh. Cooling Power (W) EER Heating Btuh COP Dehumidification (Pts/h) Sensible Heat Ratio E L E C T R I C A L D A T A : Voltage (1 Ph, 60Hz) Voltage Range Current (Amps) (A) Power Factor Amps L.R Amps F.L. Horsepower A I R F L O W D A T A : Indoor CFM Vent C...
Page 3 - Extended Heating Performance; RATING POINT
3 Extended Heating Performance PH07 PH09 PH12 Btuh Watts Amps Btuh Watts Amps Btuh Watts Amps Btuh Watts Amps RATING POINT ARI 310/380 Outdoor Dry Bulb Temp. ( ° F) 37 42 47 52 57 5366 5663 6400 7053 7789 536 545 568 577 610 2.5 2.6 2.6 2.7 2.8 6005 6399 8100 8647 9245 666 676 742 747 757 3.1 3.1 3....
Page 4 - Typical Unit Components and Dimensions; PXWS Wall; WallMaster; Front Cover
4 Typical Unit Components and Dimensions PXWS Wall Sleeve Dimensions: 16" H x 42" W x 13¾" D Series P = Packaged Terminal Unit System X = Accessory E = Cooling with or without electric heat H = Heat Pump with Auxiliary Heat Nominal Cooling Capacity 07 = 7,000 Btuh 09 = 9,000 Btuh 12 = 12...
Page 5 - Smooth side of clip on Room side; Min; Insulation; LINTEL; Mounting; Extended Wall Sleeve Installation and Sealant Locations (PXWE)
5 Note the use of a lintel under the first courseof bricks above the wall sleeve. Do not usethe wall sleeve as a lintel. The mountingscrew holes shown are to be made by theinstaller. Lintel Installation Lintel Installation Lintel Installation Lintel Installation Lintel Installation Lintel Used To Su...
Page 6 - PXDR10 DRAIN KIT; Architectural Louver Installation (PXAA); Ov; Internal Drain Kit Location and Installation (PXDR10); Gasket
6 Screw Tube Screw PXDR10 DRAIN KIT Architectural Louver Installation (PXAA) Primary Area:Condensation from thechassis collects in thesleeve in this area. ThePrimary Area is thepreferred installationlocation. Installation 1. Screw a threaded metal stud into each of the holes at the four corners of t...
Page 8 - New Construction Accessories; Friedrich PTAC Accessories
8 New Construction Accessories Friedrich PTAC Accessories MODEL NUMBER DESCRIPTION PHOTO WALL SLEEVE G-90 zinc coated steel is prepared in an eleven-step process, then powder coated formaximum coverage and protection. The wallsleeve is insulated for thermal efficiency. 16" Highx 42" Wide x 1...
Page 9 - Additional Accessories
9 PXSE SLEEVE EXTENSION RETROFIT KIT G-90 zinc coated steel, 2¼" sleeve extension attached to theroom side of the sleeve to allow for the installationof a P-Series Friedrich PTAC in a T-Series sleeve. PXDA LATERAL DUCT EXTENSION A t h r e e f o o t insulated plenum that attaches to the left or r...
Page 10 - FRIEDRICH AIR CONDITIONING CO.; Friedrich WallMaster
10 SAVE THIS CERTIFICATE. It gives you specific rights, you may also have other rights which may vary from state to state and province to province. In the event that your unit needs servicing, contact your nearest authorized service center. If you do not know the nearest service center, askthe compa...
Page 11 - DIMENSIONS
11 WALLMASTER ® P-SERIES PACKAGED TERMINAL AIR CONDITIONERS Purchaser: P.O. # Date: Project: Location: Engineer: Architect: Submitted By: For Approval: For Reference: ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH MODEL DIMENSIONS Wall Sleeve Overall Depth Width Height Depth Sleeve w...
Page 12 - Friedrich Air Conditioning Co.
12 Post Office Box 1540 · San Antonio, Texas 78295-15404200 N. Pan Am Expressway · San Antonio, Texas 78218-5212(210) 357-4400 · FAX (210) 357-4480 www.friedrich.com Printed in the U.S.A . PTACBW02 (04/02) Multiple solutions. One trusted name. Friedrich Air Conditioning Co.