Page 3 - Table of Contents
Table of Contents Air Conditioner Safety ...................................................................................................................................................... 1 Installation Requirements ...................................................................................
Page 4 - General Instructions; Refrigeration system under high pressure.; Your safety and the safety of others are very important.; WARNING; NOTICE
This Installation and Operation Manual has been designed to insure maximum satisfaction in the performance of your unit. For years of trouble-free service, please follow the installation instructions closely. We cannot overemphasize the importance of proper installation. We have added new informatio...
Page 6 - Electrical Requirements; Window installation
B C C A D Power supply cord Wiring requirements ■ 115-volt (103.5 min. - 126.5 max.) ■ 0-12 amps ■ 15-amp time-delay fuse or circuit breaker ■ Use on single outlet circuit only. ■ 230-volt (207 min. - 253 max.) ■ 0-12 amps ■ 15-amp time-delay fuse or circuit breaker ■ Use on single outlet circuit on...
Page 7 - Recommended grounding method; Power Supply Cord; To test your power supply cord:
Recommended grounding method This air cond itioner must be grounded. This air cond itioner is equipped with a powe r supply c ord having a grounded 3 prong plug. To minimize possible shoc k hazard, the cord must be plugged into a mating, grounded 3 prong out let, grounded in accor danc e with all lo...
Page 9 - Attach Top Channel; Top view; Attach foam adhesive seal
7 Window Installation (on some models) NOTES: ■ Handle air conditioner carefully and gently. ■ Be sure your air conditioner cabinet does not fall out of the opening during installation or removal. ■ The place where the power cord exits the air conditionershould be no more than 4 ft (122 cm) from a g...
Page 12 - Install Cabinet into Wood Frame; Complete Installation
A. ³⁄₄ " (19.1 mm) extending into room B. Trim B A A. Level A ■ Use 2" x 4" or thicker lumber for wood frame. 4. Apply wood preservative to the outside exposed surface. 5. Insert the frame in the wall opening. Square and level frame. 6. Attach frame securely to the wall. Install Cabinet ...
Page 14 - Starting Your Air Conditioner—Digital Control; Fan Speed; To clear Timer delay program; Money Saver
Starting Your Air Conditioner—Digital Control 1. Press POWER to turn on air co nditioner. NOTE: When the unit is turned on, it will display the previous setti ngs for the Mo de, Fan Speed and temp erature. 2. Choose mode. See “ Mode .” 3. Choose fan speed. See “ Fan Speed.” 4. Choose temperat ure. S...
Page 15 - To operate air conditioner with remote control; To turn the air conditioner on or off:; To raise the temperature:
To operate air conditioner with remote control NOTE: Remote control may vary in appe arance. NOTE: Two AAA batt eries (included) po wer the remote control. Replace batte ries after 6 months of use, or when the remote control starts to l ose power. To turn the air conditioner on or off: Press POWER. ...
Page 16 - Air Conditioner Care; Cleaning the Air Filter; Troubleshooting; Air conditioner will not operate; Cleaning the Front Panel; Annual Maintenance; Normal Sounds
Air Conditioner Care Your new air c onditioner is designed to give you many years of dep endable service. This sect ion tells you how to clean and care for you r air con ditioner properly. Call your local authorized d ealer for an annual checkup. Remember… the cost of t his service c all is your res...
Page 17 - Assistance or Service; For assistance, service or replacement parts
Air conditioner power supply cord trips (Reset button pops out) ■ Disturbances in your electrical current can trip (Reset button will pop out) the power supply cord. Press and release RESET (listen for click; Reset button will latch and remain in) to resume operation. ■ Electrical overloading, overh...
Page 18 - FIRST YEAR
Friedrich Air Conditioning Company www.friedrich.com ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge,...