Page 2 - CONTENTS; ” & 8” SUBMERSIBLE TURBINE PUMPS
CONTENTS Inspection-Receipt of Equipment....................................................... Equipment and Installation Record................................................. General Information........................................................................ Suitability of the Well.........
Page 3 - B. EQUIPMENT INSTALLATION RECORD; damages; shortages; PUMP DATA
B. EQUIPMENT INSTALLATION RECORD *Record the following details at the time of the installation and retain for future references: A. INSPECTION-RECEIPT OF EQUIPMENT Examine equipment at the time of receipt. Check that the power cable is not cut or damaged, and that all equipment is correct for the in...
Page 4 - FIVE FEET FROM THE BOTTOM OF THE WELL.; Materials; FOUNDATION
C. GENERAL INFORMATION D. SUITABILITY OF THE WELL Submersible Pumps as well as all water pumps, are designed to handle clean, cool, clear water. Water from an undeveloped well often contains excessive amounts of sand, dirt and other abrasives which can cause damage to the pump. Install the pump in a...
Page 5 - TAKE CARE TO PREVENT; DAMAGE; TO THE; F. ELECTRICAL INSTALLATION; SPLICING POWER CABLE TO MOTOR LEADS; WARNING; IN SERIOUS OR FATAL SHOCK.
*CAUTION* TAKE CARE TO PREVENT DAMAGE TO THE CABLE DURING THE INSTALLATION. F. ELECTRICAL INSTALLATION When the cable is supplied on a reel, support the reel on a piece of pipe laid across a pair of sturdy saw horses. Locate the reel about 6 ft. from the well so that the cable unwinds from the top. ...
Page 6 - TO
ELECTRICAL INSTALLATION & TESTS Employ a competent electrician to do the wiring in accordance with local electrical codes. Conventional overhead or underground installation is satisfactory for the electrical power transmission to the Well Head. Check that the power supply corresponds with that s...
Page 7 - Starter; TO ELECTRICAL CODE REQUIREMENTS.; H. ACCESSORIES WITH INSTALLATION; LIGHTNING ARRESTERS
Check that the currents in the individual phases of a 3-phase system are approximately equal. Where there is considerable difference between them, change all 3 connections at the starter as shown below (so that rotation remains the same) to obtain the most consistent readings. Starter L1 L2 L3 cable...
Page 8 - FLOATLESS LIQUID LEVEL CONTROL; I. OPERATIONAL CHECKUP
FLOATLESS LIQUID LEVEL CONTROL The sensing elements of a fl oatless liquid level control consists of 2 electrodes suspended in the well by insulated wires. These wires connect to a relay which serves as a pilot switch to the starting equipment. The lower electode is set just above the pump, and the ...
Page 9 - Franklin Pump Systems, Inc.
U.S. LIMITED WARRANTY* Franklin Pump Systems, Inc. Franklin Pump Systems, Inc. warrants its new products to be free of defects in material and workmanship for a period of 1 year from date of installation or 2 years from date of manufacture, whichever comes fi rst, WHEN installed in a domestic water ...