TABLE OF CONTENTS Page I © 2004-2007 DH Instruments, a Fluke Company T T A A B B L L E E O O F F C C O O N N T T E E N N T T S S T A B L E O F C O N T E N T S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I T A B L E S ....
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page II 3.2.2 GAUGE AND NEGATIVE GAUGE MODES WITH AN AXXX (ABSOLUTE) Q-RPT, DYNAMIC COMPENSATION FOR ATMOSPHERIC PRESSURE ............................................................................... 19 3.2.3 MULTIP...
TABLES & FIGURES Page V © 2004-2007 DH Instruments, a Fluke Company T T A A B B L L E E S S Table 1. Reference Pressure Transducer (Q-RPT) Module Designations and Ranges ............................. 3 Table 2. RPM4 Packing List.......................................................................
ABOUT THIS MANUAL Page VII © 2004-2007 DH Instruments, a Fluke Company A A B B O O U U T T T T H H I I S S M M A A N N U U A A L L This manual is intended to provide the user with the basic information necessary to operate an RPM4 reference pressure monitor. It also includes a great deal of addition...
1. INTRODUCTION Page 1 © 2004-2007 DH Instruments, a Fluke Company 1 1 . . I I N N T T R R O O D D U U C C T T I I O O N N 1 . 1 P R O D U C T O V E RV I E W RPM4 is a stand-alone, microprocessor driven, reference pressure monitor intended to precisely measure gas or liquid pressure in a wide variet...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 2 1 . 2 S P E C I F I C AT I O N S 1 . 2 . 1 G E N E R A L S P E C I F I C A T I O N S Power Requirements 85 to 264 VAC, 50/60 Hz, 25 VA max consumption and 12VDC, 1.2 A Operating Temperature Range 15 to 35 °C St...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 4 Warm Up Time 30 minute temperature stabilization recommended from cold power up. Resolution To 1 ppm, user adjustable Compensated Temperature Range 5 to 35 °C Acceleration Affect ± 0.008 % /g maximum, worst axi...
1. INTRODUCTION Page 5 © 2004-2007 DH Instruments, a Fluke Company 1 . 2 . 3 B A T T E R Y A N D C H A R G E R P A C K Power Requirements 100 to 240 VAC, 50/60 Hz, 15 W max consumption Operating Temperature Range 0 to 50 °C Storage Temperature Range - 20 to 50 °C Vibration Meets MIL-T-28800D Weight ...
2. INSTALLATION Page 7 © 2004-2007 DH Instruments, a Fluke Company 2 2 . . I I N N S S T T A A L L L L A A T T I I O O N N 2 . 1 U N PA C K I N G A N D I N S P E C T I O N 2 . 1 . 1 R E M O V I N G F R O M P A C K A G I N G RPM4 is delivered in a corrugated container with polyethylene inserts to hol...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 8 2 . 2 S I T E R E Q U I R E M E N T S Install RPM4 on a flat, stable surface at a convenient height. The front feet can be extended so that the unit can be inclined for easier viewing. The RPM4 can also be moun...
2. INSTALLATION Page 9 © 2004-2007 DH Instruments, a Fluke Company 2.3.2.2 REAR PANEL 1. 12VDC Power Supply Connection 2. Remote [ENT] Connector 3. IEEE-488 Connector 4. COM2 Connector 5. COM1 Connector 6. Power Switch 7. Fuse 8. Electrical Power Connector (IEC-320-C13) 9. Fan 10. TEST(+) Pressure P...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 10 2 . 3 . 4 R E M O T E [ E N T ] C O N N E C T I O N ( F O O T S W I T C H O R O T H E R S W I T C H ) Connect the optional remote ENTER footswitch, if available or a user supplied switch fitted to the optional...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 12 2 . 3 . 8 T U R N O F F A B S O L U T E A N D N E G A T I V E G A U G E M O D E ( A X X X R P T ) If your RPM4 has one or two Axxx (absolute) Q-RPTs, it is able to operate in gauge, negative gauge and absolute...
2. INSTALLATION Page 13 © 2004-2007 DH Instruments, a Fluke Company 2 . 4 . 2 C H E C K P R E S S U R E M E A S U R E M E N T O P E R A T I O N 2.4.2.1 CHECKING ABSOLUTE MODE PRESSURE MEASUREMENT If the RPM4 has an Axxx (absolute) Q-RPT, check that it operates properly in absolute mode. Make sure th...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 14 2 . 5 S H O R T T E R M S TO R A G E The following is recommended for short term storage of RPM4: Vent the RPM4 test port Switch power OFF.
3. OPERATION Page 15 © 2004-2007 DH Instruments, a Fluke Company 3 3 . . O O P P E E R R A A T T I I O O N N 3 . 1 U S E R I N T E R FA C E RPM4 is designed to offer a balance between simple, straight forward operation and the availability of a wide variety of advanced functions with a high level of...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 16 P R E S S U R E 1 U N I T M h z R R D D I S P L A Y F U N C I O N n n / n n DISPLAY FIELD NAME PURPOSE CONTENTS SECTION 1. PRESSURE1 Measured pressure Displays pressure measured by the active Q-RPT Numerical p...
3. OPERATION Page 17 © 2004-2007 DH Instruments, a Fluke Company 3 . 1 . 2 F U N C T I O N / D A T A K E Y P A D L A Y O U T A N D P R O T O C O L The RPM4 has a function/data keypad for local operator access to direct functions, function menus and for data entry. 1. The Function/Data keys allow ver...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 18 3 . 1 . 3 R E M O T E [ E N T ] ( E N T E R ) F O O T S W I T C H The optional remote ENTER function is a switch that duplicates the function of the front panel [ENT] key. The remote ENTER function is serviced...
3. OPERATION Page 19 © 2004-2007 DH Instruments, a Fluke Company In differential measurement mode (see Section 3.3.3.1), the LED Ready/Not Ready indication applies to the differential pressures. In parallel measurement mode (see Section 3.2.4), the LED Ready/Not Ready indication applies to the avera...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 20 Table 3. Position Designators of Q-RPTs in an RPM4 System Q-RPT POSITION DISPLAY SYMBOL* Q-RPT with highest maximum pressure, installed in HIGH RPT position Hi Q-RPT with lower maximum pressure in dual Q-RPT R...
3. OPERATION Page 21 © 2004-2007 DH Instruments, a Fluke Company Table 4. Settings and What They Are Specific To (Range, Measurement Mode, Q-RPT, System) SETTING PURPOSE SPECIFIC TO SECTION [Unit] Set pressure unit of measure Range 3.3.2 [Mode] Set pressure measurement mode (absolute, gauge, negativ...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 22 AutoZ Make sure AutoZ is ON for all RPTs and measurement modes (see Section 3.5.1). Certain RPM4 settings may be changed when an RPM4 is operated with a PPC3. Settings that may be changed when an RPM4 is used ...
3. OPERATION Page 23 © 2004-2007 DH Instruments, a Fluke Company 3 . 2 . 6 U S E O F T H E 1 2 V D C B A T T E R Y / C H A R G E R P A C K An optional 12VDC battery/charger pack is available to supply power to RPM4s 12VDC power connection (see 1.2.3). The battery/charger pack combines the battery an...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 24 3 . 2 . 7 S D S S E L F D E F E N S E S Y S T E M Q-RPT modules designated 7M or lower that are NOT liquid filled are equipped with the SDS self defense system. The SDS system includes hardware and embedded so...
3. OPERATION Page 25 © 2004-2007 DH Instruments, a Fluke Company 3 . 2 . 8 D I R E C T F U N C T I O N K E Y S S U M M A R Y Table 5 provides a brief summary of direct function key operation. It may be useful to keep a copy of this summary near the RPM4, especially when first becoming acquainted wit...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 26 OPERATION Pressing the [RANGE] function key activates the range viewing and selecting function. When the [RANGE] function key is first pressed, the active range is displayed. For example: 1. Q-RPT designator...
3. OPERATION Page 27 © 2004-2007 DH Instruments, a Fluke Company Internally, RPM4 always operates in Pascal (Pa), the SI unit of pressure. Values of pressure are represented in other units by the application of conversion factors to convert from Pa (see Section 7.2.1). OPERATION To change the acti...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 28 Gauge Measures pressure relative to atmosphere (zero is ambient pressure). Range is from zero gauge to full scale, full scale must be greater than zero. Negative Gauge Measures pressure relative to atmosphere ...
3. OPERATION Page 29 © 2004-2007 DH Instruments, a Fluke Company If an Axxx Q-RPT is active, all thee measurement modes are supported: absolute, gauge and negative gauge. Only gauge is available if absolute and negative gauge modes have been turned OFF in calibration (see Section 5.2.5). If a Gxxx Q...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 30 The following operating conditions are specific to differential mode: Main run screen measured pressure display The display of measured pressure in the main run screen is the difference between the Hi and the ...
3. OPERATION Page 31 © 2004-2007 DH Instruments, a Fluke Company The AutoRange function simplifies the task of selecting the Q-RPT best suited to cover a specific test range and setting measurement parameters appropriately for the range. These are set automatically based on operator entry of desired...
3. OPERATION Page 33 © 2004-2007 DH Instruments, a Fluke Company 3 . 3 . 5 [ L E A K C K ] PURPOSE To run an automated leak check routine that determines the leak rate of the system connected to the RPM4 active Q-RPT TEST(+) port. PRINCIPLE The LEAK CHECK function is provided as a means of check...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 36 When RPM4 is initialized as an external device to a PPC3 pressure controller, the RPM4 front panel keypad is locked out and the second line of the display becomes: <PPC3 EXT DEV: IDLE> (if RPM4 is initia...
3. OPERATION Page 37 © 2004-2007 DH Instruments, a Fluke Company Pressing [ENT] while in the Average DISPLAY aborts the current averaging period and causes a new one to begin. [ENT] can thus be use to trigger a new averaging period on demand. In the Average DISPLAY the Ready/Not Ready indication app...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 38 The Rate DISPLAY is the default display except in differential measurement mode in which the default DISPLAY is RPT. To go to a DISPLAY other than Rate, press [DISPLAY] and make a new DISPLAY choice (see Secti...
3. OPERATION Page 39 © 2004-2007 DH Instruments, a Fluke Company 3.3.6.4 RPT PURPOSE To activate the RPT DISPLAY. See Section 3.3.6, Principle. The RPT DISPLAY is only available in RPM4s with two Q-RPTs. OPERATION For the sake of clarity, when describing the RPT DISPLAY, the Q-RPT displayed on...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 40 If the inactive RPT is equipped with SDS Self Defense System (see Section 3.2.7), SDS will almost certainly be CLOSED when the RPT DISPLAY is activated. SDS can be OPENED on the inactive RPT using [SPECIAL], &...
3. OPERATION Page 41 © 2004-2007 DH Instruments, a Fluke Company 3.3.6.6 Freeze PURPOSE To activate the Freeze DISPLAY. See Section 3.3.6, Principle. OPERATION To activate the Freeze DISPLAY press [DISPLAY] , <6Freeze> . Pressing <6Freeze> returns to the main run screen with the Fr...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 42 OPERATION To activate the Clean DISPLAY press [DISPLAY] , <7Clean> . Pressing <7Clean> returns to the main run screen with the Clean DISPLAY active. With the Clean DISPLAY active the main run scr...
3. OPERATION Page 43 © 2004-2007 DH Instruments, a Fluke Company OPERATION To access the HEAD function, press [HEAD] . The display is: 1. Test fluid currently specified for the head correction. 2. Edit field for head height. Edit head height: + 25 cm N2 Edit the head height to the desired value. P...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 44 PRINCIPLE SDS is a self defense system to protect RPM4 Q-RPTs from overpressure. SDS CLOSES automatically to protect a Q-RPT that is not active. In a two Q-RPT RPM4, activating one Q-RPT automatically CLOSES...
3. OPERATION Page 45 © 2004-2007 DH Instruments, a Fluke Company Use [SDS] to OPEN SDS if it is CLOSED for the active Q-RPT and/or to CLOSE SDS for the active and inactive Q-RPT. When [SDS] is pressed, there are three possible results depending whether the active Q-RPT is SDS equipped and ON (see Se...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 46 3.3.8.1 SDS IN DIFFERENTIAL AND PARALLEL MEASUREMENT MODES In differential and parallel measurement modes, opening SDS opens SDS for BOTH the Hi and Lo Q-RPTs. Before opening SDS, be certain that the pressure ...
3. OPERATION Page 47 © 2004-2007 DH Instruments, a Fluke Company 3.3.9.1 [AUTOZ] IN GAUGE AND NEGATIVE GAUGE MODE PURPOSE To “rezero” the active Q-RPT in gauge measurement mode. See Section 3.5.1, Principle for a full explanation of the AutoZ function. OPERATION For the AutoZ function key to r...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 48 3.3.9.2 [AUTOZ] IN ABSOLUTE MODE PURPOSE To “rezero” the active Q-RPT in absolute measurement mode See Section 3.5.1, Principle for a full explanation of the AutoZ function. OPERATION For the AutoZ funct...
3. OPERATION Page 49 © 2004-2007 DH Instruments, a Fluke Company When the run AutoZ selection is made, if a HEAD correction is currently active (see Section 3.3.7) the head correction is momentarily disabled while running AutoZ to avoid “zeroing out” the head value. The value of P offset is always d...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 50 To access run AutoZ by COM2 press [AutoZ] , <2COM2> . The display is: 1. Real time pressure reading (without head correction), pressure unit of measure and measurement mode of the active Q-RPT. 2. Active...
3. OPERATION Page 51 © 2004-2007 DH Instruments, a Fluke Company 3.3.9.3 AUTOZ IN DIFFERENTIAL MODE PURPOSE To compensate for the offset between the Hi Q-RPT and the Lo Q-RPT at the operating “line pressure” in differential measurement mode. See Section 3.5.1, Principle for a full explanation of...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 52 PRINCIPLE This feature not available at the time of release of this manual. Check www.dhinstruments.com for new RPM4 embedded software releases and manual updates. OPERATION Feature not available at the ti...
3. OPERATION Page 53 © 2004-2007 DH Instruments, a Fluke Company Once the AutoRange range is set up as desired, press [SETUP] , <1range> , <1save> . The display is: 1. Indication that this is a range to be saved. 2. Designator and position of the Q-RPT used by the range to be saved. 3. P...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 54 digit to the right. For example, resolution of 0.001 % on a range of 150 kPa is 150 X 0.001 % = 0.0015 which is rounded down to 0.001 kPa. Default resolution is 10 ppm of active range span. Resolution is set a...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 56 OPERATION To view or edit upper and lower limits press [SETUP] , <4UL> . If the current measurement mode is absolute or gauge, there is an upper limit only. The display is: 1. Entry field for upper lim...
3. OPERATION Page 57 © 2004-2007 DH Instruments, a Fluke Company 3.4.4.1 OVER PRESSURE FUNCTION In addition to the UL function, RPM4 has an over pressure function. The over pressure function executes when a Q-RPT measures a pressure that is 104 % of its default span. The G15K and BG15K Q-RPTs also h...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 58 3 . 5 . 1 < 1 A U T O Z > PURPOSE To offset the RPM4 Q-RPT(s) readings relative to a reference value in order to compensate for possible changes in Q-RPT zero between full recalibrations. In differenti...
3. OPERATION Page 59 © 2004-2007 DH Instruments, a Fluke Company The AutoZ function can be turned ON and OFF. Table 7 summarizes the effect of AutoZ ON and OFF for the three Q-RPT types in different measurement modes. AutoZ in absolute measurement mode with an Axxx Q-RPT Q-RPTs with the designation ...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 60 AutoZ in gauge measurement mode with a Gxxx or BGxxx Q-RPT Q-RPTs with the designation Gxxx or BGxxx are intrinsically gauge. They have an atmospheric ( TEST(-) ) reference port and measure gauge pressure (dif...
3. OPERATION Page 61 © 2004-2007 DH Instruments, a Fluke Company “line pressure”. The following simple recommendations will help assure that you use this feature to best advantage. • In gauge and differential measurement mode: Always leave AutoZ ON when operating. • In absolute measurement mode: Alw...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 62 Select <3edit> to edit the value of P offset for the active Q-RPT and measurement mode (see Section 3.5.1.1). The value of P offset is always displayed and entered in Pascal (Pa). 3.5.1.1 EDIT AUTOZ The ...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 64 3.5.2.4 <5RS232 SELF-TEST> The RS232 self-test is provided to check the RPM4 COM ports and the interface cable independently of an external device or computer. If you are having difficulty communicating ...
3. OPERATION Page 69 © 2004-2007 DH Instruments, a Fluke Company Access to changing security levels can be left open, or be protected by a password. Security Levels The security levels are structured to support typical operating environments as follows: None This level is intended for use only by th...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 70 Table 8. Security Levels FUNCTION LOW MEDIUM HIGH [RANGE] • [ENT] (AutoTest) • [UNIT] • [MODE] • [AutoRange] • • [LEAK CK] • [DISPLAY] • • [HEAD] • [SDS] • [AutoZ] (in absolute mode) • • [SETUP] • [SETUP], <...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 72 PRINCIPLE The [UNIT] function key makes available a choice of six default pressure units (US or SI units depending on whether the RPM4 has been factory set as US or SI) (see Section 3.3.2). RPM4 also support...
3. OPERATION Page 73 © 2004-2007 DH Instruments, a Fluke Company 3 . 5 . 7 < 7 I N T E R N A L > PURPOSE To view, set, adjust, and maintain various aspects of RPM4’s internal operation. OPERATION To access the internal selections press [SPECIAL] , <7internal> . The display is: 1baro ...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 74 OPERATION RPM4’s that have only G100K or G200K Q-RPTs (no Axxx, G15K or BG15K) are NOT equipped with an on-board barometer. To view the current reading of the on-board barometer press [SPECIAL] , <7intern...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 78 3 . 5 . 9 < 9 R E S E T > PURPOSE To reset various RPM4 settings to default or factory values. PRINCIPLE RPM4 stores its user definable settings in non-volatile memory. The reset menu allows the user...
3. OPERATION Page 79 © 2004-2007 DH Instruments, a Fluke Company Table 11. Reset – Sets RESET RESULT SEE SECTION [UNIT] Pressure unit of measure to first of the six available 3.3.2 [MODE] Measurement mode to the native mode of the Q-RPT 3.3.3 [RANGE] Hi Q-RPT default range 3.3.1 [HEAD] 0 cm height a...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 80 Table 12. Reset – Cal RESET RESULT SEE SECTION All Q-RPT Calibration Coefficients PA to zero, PM to 1 5.2.1.1, 5.2.7 Axxx Q-RPT absolute and negative gauge mode ON 5.2.5 On-board Barometer Calibration Coeffici...
4. REMOTE OPERATION Page 81 © 2004-2007 DH Instruments, a Fluke Company 4 4 . . R R E E M M O O T T E E O O P P E E R R A A T T I I O O N N 4 . 1 O V E RV I E W Most of the RPM4 front panel functions can also be executed by commands from a remote computer. The host computer can communicate to the RP...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 82 4.2.1.2 IEEE-488 The RPM4 IEEE-488 interface is located on the back of the unit. The physical and electrical interface conforms to IEEE Std 488.1-1987 Subset E2 and IEEE Std. 488.2-1992. You should not attempt...
4. REMOTE OPERATION Page 83 © 2004-2007 DH Instruments, a Fluke Company 4 . 3 . 1 C L A S S I C P R O G R A M M E S S A G E F O R M A T Each program message sent is also a query. You can only send one program message to the RPM4 at time. After sending any program message, you must wait for the RPM4 ...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 84 Examples: • IEEE-488 enhanced mode command series using query operator: “*CLS?” (Clear the error queue. Wait for reply) “UNIT? KPA” (Generates a reply. User must wait for reply before continuing) “MMODE? A” (G...
4. REMOTE OPERATION Page 85 © 2004-2007 DH Instruments, a Fluke Company 4 . 4 C O M M A N D S 4 . 4 . 1 P R O G R A M M I N G M E S S A G E S Some commands accept an optional suffix. This suffix can be used to specify the explicit Q-RPT to address. In most cases, each Q-RPT in the RPM4 operates as a...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 86 COMMAND ‘ n ’ indicates an optional suffix DESCRIPTION ULn Read or set the upper limit for the current range. UNITn Read or set the pressure unit of measure for the current range. VER Read the RPM4 software ve...
4. REMOTE OPERATION Page 87 © 2004-2007 DH Instruments, a Fluke Company 4 . 4 . 3 P R O G R A M M E S S A G E D E S C R I P T I O N O V E R V I E W Each program message description is separated into the following sections: Purpose A brief description of the programs message’s function. Command This ...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 88 4 . 4 . 4 P R O G R A M M E S S A G E D E S C R I P T I O N S # Purpose To allow the host PC to communicate with a device connected to the RPM4 COM2 port. Classic “#xx” Arguments xx: The string to send out of ...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 108 ZOFFSETn Purpose Read or set the AutoZ pressure offset (P offset ) for the specified or active Q-RPT in the current measurement mode. Command Query “ZOFFSET n GaOffset , AbsOffset , DifOffset ” “ZOFFSET n ?” ...
4. REMOTE OPERATION Page 109 © 2004-2007 DH Instruments, a Fluke Company Status Byte Register (“ ∗ STB?” or ” ∗ SRE n”) OPER (128) RQS/MSS (64) Standard Event Status Register (“ ∗ ESR?” or “ ∗ ESE n”) ESB (32) ←←← PON (128) URQ (64) CMD (32) EXE (16) DDE (8) QYE (4) RQC (2) OPC (1) MAV (16) ←←← OUTP...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 110 4 . 5 . 3 S T A N D A R D E V E N T R E G I S T E R The RPM4 contains an 8 bit Standard event register that reflects specific RPM4 events. Enabled events in this register will set or clear the ESB bit of the ...
5. MAINTENANCE, ADJUSTMENTS AND CALIBRATIONS Page 115 © 2004-2007 DH Instruments, a Fluke Company 5 5 . . M M A A I I N N T T E E N N A A N N C C E E , , A A D D J J U U S S T T M M E E N N T T S S A A N N D D C C A A L L I I B B R R A A T T I I O O N N 5 . 1 O V E RV I E W RPM4 was designed for mai...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 116 The calibration process is performed independently on each Q-RPT to arrive at its optimal fit. CalTool for RPTs software provided with the RPM4 supports the calibration process of RPM4 Q-RPTs. CalTool and its...
5. MAINTENANCE, ADJUSTMENTS AND CALIBRATIONS Page 117 © 2004-2007 DH Instruments, a Fluke Company readings with PA = 0 and PM = 1. Then applying the as received PA and PM and P offset values to the readings calculates as received readings (the readings that the transducer would have made with the ol...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 118 • Measurement uncertainty of ± 0.008 % of reading for Standard Class Q-RPTs or ± 0.005 % of reading for Premium Class Q-RPTs . A standard with higher measurement uncertainty may be used but RPM4 measurement u...
5. MAINTENANCE, ADJUSTMENTS AND CALIBRATIONS Page 119 © 2004-2007 DH Instruments, a Fluke Company 5 . 2 . 4 R E C O M M E N D E D C A L I B R A T I O N P O I N T S E Q U E N C E Calibration adjustments to RPM4 Q-RPTs are made by altering calibration coefficients, PA and PM (see Section 5.2.1.1). To ...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 120 Table 23. Calibration Point Sequence, Standard Class, BGxxx Q-RPTs CALIBRATION SEGMENT POINT NO. POINT [% OF SPAN] 1 1 0 % 2 25 % 3 50 % 4 75 % Ascending 5 100 % 6 75 % 7 50 % 8 25 % Descending 9 0 % 1. The B...
5. MAINTENANCE, ADJUSTMENTS AND CALIBRATIONS Page 121 © 2004-2007 DH Instruments, a Fluke Company Table 25. Calibration Point Sequence, Premium Class, Axxx and Gxxx Q-RPTs CALIBRATION SEGMENT POINT NO. POINT [% OF SPAN] 1 Lowest Pressure 1 2 5 % 3 10 % 4 15 % 5 20 % 6 30 % 7 40 % 8 50 % 9 60 % 10 80...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 122 5 . 2 . 5 T U R N I N G O F F A B S O L U T E A N D N E G A T I V E G A U G E MEASUREMENT MODES FOR AXXX (ABSOLUTE) Q-RPTS PURPOSE To prevent operation in absolute and negative gauge measurement modes on an...
5. MAINTENANCE, ADJUSTMENTS AND CALIBRATIONS Page 123 © 2004-2007 DH Instruments, a Fluke Company • Absolute and negative gauge measurement modes ON or OFF (Axxx Q-RPTs only) – See Section 3.3.3, PRINCIPLE for complete information on measurement modes. This is set to OFF if an Axxx Q-RPT was calib...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 124 been made in any of the calibration screens. Pressing [ESC] in any edit screen exits the edit screen without activating any changes. The value of PA is always in Pascal (Pa). The value of PM is dimensionless....
5. MAINTENANCE, ADJUSTMENTS AND CALIBRATIONS Page 125 © 2004-2007 DH Instruments, a Fluke Company Run the recommended calibration point sequence for the Q-RPT (see Section 5.2.4). Record the pressure applied by the standard and the RPM4 reading at each calibration point. Dwell at least 60 seconds at...
5. MAINTENANCE, ADJUSTMENTS AND CALIBRATIONS Page 127 © 2004-2007 DH Instruments, a Fluke Company 5 . 5 S U B A S S E M B LY D E S C R I P T I O N A N D L O C AT I O N 1. Micro Card 2. Power Supply Module (beneath Driver Board) 3. Driver Board 4. On-Board Barometer (if present) 5. Lo Q-RPT module (i...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 128 5 . 5 . 3 D R I V E R B O A R D The driver board is controlled by the mini micro board (see Section 5.5.1). It supports: • 12 V drivers for internal solenoid valve actuation • Frequency counters (2) for readi...
5. MAINTENANCE, ADJUSTMENTS AND CALIBRATIONS Page 129 © 2004-2007 DH Instruments, a Fluke Company 5 . 6 Q - R P T M O D U L E P N E U M AT I C S C H E M AT I C S Axxx Q-RPT >A10M (No SDS) Axxx Q-RPT <A10M VALVE STATE CONDITION A B SDS Open O C SDS Closed C O Power off C O Gxxx or BGxxx Q-RPT V...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 130 The pneumatic schematic for RPM4’s with two Q-RPT modules is the same as for the single Q-RPT modules in Figure 8 with the following exceptions: • If both modules use the barometer, the barometer is connected...
6. TROUBLESHOOTING Page 131 © 2004-2007 DH Instruments, a Fluke Company 6 6 . . T T R R O O U U B B L L E E S S H H O O O O T T I I N N G G RPM4 is a sophisticated pressure setting and measuring instrument with advanced on-board features and functions. Before assuming that unexpected behavior is cau...
7. APPENDIX Page 135 © 2004-2007 DH Instruments, a Fluke Company 7 7 . . A A P P P P E E N N D D I I X X 7 . 1 R E M O T E [ E N T ] The RPM4 remote ENTER function operates by detecting the open or closed status of the REMOTE ENTER switch. The normal status of the ENTER switch is OPEN. When RPM4 det...
RPM4™ OPERATION AND MAINTENANCE MANUAL © 2004-2007 DH Instruments, a Fluke Company Page 136 7 . 2 U N I T C O N V E R S I O N 7 . 2 . 1 P R E S S U R E RPM4 performs all internal calculations in SI units. Numerical values input or output in other units are converted to SI immediately after entry and...
8. WARRANTY Page 137 © 2004-2007 DH Instruments, a Fluke Company 8 8 . . W W A A R R R R A A N N T T Y Y 8 . 1 O V E RV I E W Except to the extent limited or otherwise provided herein, DH Instruments warrants for one year from purchase, each new product sold by it or one of its authorized distributo...
Fluke Manuals
-
Fluke 54IIB
Manual
-
Fluke 1750
Manual
-
Fluke 1502A
Manual
-
Fluke 187
Manual
-
Fluke 99B
Manual
-
Fluke Thermometer 576
Manual
-
Fluke PM8907
Manual
-
Fluke 2686A
Manual
-
Fluke 574
Manual
-
Fluke 23
Manual
-
Fluke 196C
Manual
-
Fluke 80T-150U
Manual
-
Fluke 80K-40
Manual
-
Fluke 335D
Manual
-
Fluke 68X Series
Manual
-
Fluke PM3370B
Manual
-
Fluke 199
Manual
-
Fluke 8010A
Manual
-
Fluke 6062a
Manual
-
Fluke 5626/5628
Manual