Page 3 - The DishDrawer MUST; WARNING
Weight - Full 93lb (42kg) Prefinished - Empty 62lb (28kg) Prefinished Electrical 110-120VAC 3 pin socket outlet Drying Residual Heat & Fan Assisted Water Connection Recommended Hot 140 ° F (60 ° C) Max. Water Pressure Maximum 139 p.s.i. (960 kpa)Minimum 4.3 p.s.i. (30 kpa) GENERAL INFORMATION SE...
Page 5 - PLUMBING - DRAINAGE OPTIONS
Note: DS602 Prefinished Model is shown. There is no variation in plumbing between DS602 Prefinished Model and DS602I Integrated Model. Options 1 and 2 are the preferred options. PLUMBING - DRAINAGE OPTIONS Improper connection of the equipment-grounding conductor can result in a risk of electric shoc...
Page 7 - TIP; IMPORTANT
SECTION 2 FITTING THE DISHDRAWER Ensure the cavity is at least 22 7 / 8 " (580mm) deep. TIP STEP 2.1 DISHDRAWER MOUNTING HOLE LOCATIONS 2.1.1 Draw the cavity center line on thesupporting cabinetry. 2.1.2 Center Template in cavity using V-notch on the front of the Template. 2.1.4 Mark and drill f...
Page 8 - STEP 2.2 CONNECTING THE SERVICES; Product Specifications &
STEP 2.2 CONNECTING THE SERVICES Ensure the edges of the Service Hole are smooth or covered. (See Step 1.2 - Product Specifications & Cavity Dimensions.) If the Services Hole is through a metal partition, the hole must be protected with the Edge Protector provided. DO NOT adjust the length of th...
Page 9 - The Product; MUST NOT; be plugged in at this; If permanently connecting,
The Product MUST NOT be plugged in at this stage. WARNING 2.2.6 If required, trim the Single Connector to the size which matches the waste tee or air break to be used. There are ribs provided to guide cutting. When using the Single Connector, the hose should be pushed in firmly, 5 clicks. Remember t...
Page 10 - STEP 2.3 FLEXIBLE EXTRUSION ATTACHMENT FOR; Services should be
STEP 2.3 FLEXIBLE EXTRUSION ATTACHMENT FOR 24 (610mm) CAVITY Wiring, Plumbing and Services should be completed before attaching the flexible extrusion. TIP 2.3.1 Flexible Extrusions are supplied to enable the installer to help fill any excess space between the sides of the DishDrawer and the cavity...
Page 11 - SECTION 3; INSERTING DISHDRAWER INTO CAVITY; Refer to
SECTION 3 DO NOT push against the middle of the drawer. The DishDrawer should not support any part of the kitchen cabinetry. WARNING Make sure the inlet and drain hose and main flex are not restricted or damaged by carefully pulling them through the Services Hole as the DishDrawer is being pushed ba...
Page 12 - SECTION 4; STEP 4.1 INTEGRATED DRAWER FRONT DIMENSIONS
Recommended Drawer Front thickness for Integrated product is 5 / 8 " to 3 / 4 " (16mm - 18mm). IMPORTANT SECTION 4 INFORMATION FOR CABINET MAKER FOR INTEGRATED DISHDRAWER STEP 4.1 INTEGRATED DRAWER FRONT DIMENSIONS Drawer Front material must be suitable for damp conditions or adequately seal...
Page 13 - Drawer Front Air Flow
A minimum clearance of 3 / 32 (2.5mm) must be maintained between the Drawer Front and existing cabinetry, except between the underside of the Drawer Front and the shelf, where a 1 / 4 (6mm) clearance is needed for product venting. IMPORTANT I N T E G R A T E D P R O D U C T O N L Y Page DS_12 Dr...
Page 14 - Badge Cutout Dimensions
Accuracy is essential when cutting the Badge Mounting Hole to ensure a neat fit to hold the badge. IMPORTANT IMPORTANT All marking out to be done on the back surface of the Drawer Front. When mounting the handle, ensure fastenings do not protrude beyond the back surface of the Drawer Front. I N T E ...
Page 15 - CAUTION
I N T E G R A T E D P R O D U C T O N L Y Use of a depth gauge is recommended when drilling out holes for Drawer Front Mounting Panel. WARNING Page DS_14 4.1.5 Drawer Front Mounting Bracket Nut Holes Using a 11 / 32 (8.5mm) diameter drill bit, drill out the four screw holes in each door panel to a...
Page 16 - SECTION 5; STEP 5.1 CHANGING THE INTEGRATED BADGE ENCLOSURE; INTEGRATED DRAWER FRONT INSTALLATION; STEP 5.2 DISASSEMBLING THE INTEGRATED BADGE ASSEMBLY
SECTION 5 STEP 5.1 CHANGING THE INTEGRATED BADGE ENCLOSURE INTEGRATED DRAWER FRONT INSTALLATION STEP 5.2 DISASSEMBLING THE INTEGRATED BADGE ASSEMBLY There are several different colored Integrated badges to choose from. They include black, chrome, satin & brass. Two color options are provided wit...
Page 18 - View of Slide Hooks
STEP 5.5 FITTING THE DRAWER FRONT TO THE DISHDRAWER Use a small amount of liquid soap along the lip of the seal to aid the Drawer Front to slide on easily against the seal. The Electronics Board is an electrostatic sensitive device. Ensure you are adequately grounded when connecting or disconnecting...
Page 20 - FINAL CHECKS; STEP 7.1 INSTALLATION WET TEST; SECTION 7; STEP 7.2 TROUBLESHOOTING; LEAVE; ALL; LITERATURE WITH THE CUSTOMER.
SECTION 12 FINAL CHECKS STEP 7.1 INSTALLATION WET TEST SECTION 7 STEP 7.2 TROUBLESHOOTING Water underneath DishDrawer, check the hose connections and hose for leaks. Water around water supply and drainage connections - check connections, existing plumbing and hoses for leaks. Excessive water remaini...