Page 2 - DCS; MODELS
2 Brand: Fisher & Paykel DCS MODELS MARKETS DD605/DS605 NZ, AU, UK, EU, DK, US,CA DD60 NZ, AU, UK,EU, DK, DD90 NZ, AU, UK,EU,DK DD24 US, CA DD36 US, CA
Page 3 - CONTENTS
3 CONTENTS 1 FAULT FINDING PROCEDURE ............................................... 4 2 F9 FAULT CODE....................................................................... 5 3 CONTROLLER TYPES ............................................................. 5 4 CHECKING SPECIFIC COMPONENTS .............
Page 4 - FAULT FINDING PROCEDURE
4 1 FAULT FINDING PROCEDURE Before beginning, determine if the controller fitted is a PH5 or PH5.1 controller, as the fault finding procedure is slightly different for each (See Section 3 - Controller Types). 1. If it is a double product, one tub will be displaying an F9 and the other will most like...
Page 5 - F9 FAULT CODE; Display; CONTROLLER TYPES; There are 2 versions of controller:; Phase 5.1 series controller; Part Number
5 2 F9 FAULT CODE Display Secondary Panel Power Supply / Controller Fault The product will disable power supply, log the fault, lock out the user and report to the user via a fault code. Note: The isolation relay will be disabled. Power to the product will need to be disconnected then reconnected fo...
Page 6 - CHECKING SPECIFIC COMPONENTS; Device
6 4 CHECKING SPECIFIC COMPONENTS Device Connector Pin Pair Description Fill valve P205 10 & 11 65 +/- 10 ohm Lid motor P205 6 &7 Check if open or short circuit Lid motor P205 8 & 9 Check if open or short circuit Rinse aid pump P204 1 & 2 65 +/- 10 ohm Detergent diverter P204 3 & ...
Page 8 - Component Checking Procedure; Number Procedure
8 4.1 Component Checking Procedure Number Procedure Check Dropper Resistor: This is checked at the power connector harness at the controller (P101) Remove the harness from the controller, and using a multimeter check the resistance between pins 4 & 5 – be careful not to spread the pins with the ...
Page 15 - Check the Chassis board:
15 Check the Chassis board: Check the chassis board (mains filter board) for any corroded/ burnt contacts or dry joints, to do this remove the mains filer board from the housing. 9
Page 16 - DIAGNOSTICS; DishDrawer Diagnostics; Display Mode – Level One; Pre Finished
16 5 DIAGNOSTICS 5.1 DishDrawer Diagnostics DishDrawer™ diagnostics can only be entered in Power Off mode, i.e. when there is no display on the LCD, or the badge LEDs are off. Note: If the product has been powered off at the wall due to a fault code error, once power is turned back on, wait 20 secon...
Page 17 - Will show the following LED’s on secondary display
17 5.1.2 Hardware Output Test Mode – Level Two This level tests all the hardware outputs and inputs. The LCD display shows ‘HO’ Pre Finished Integrated and Flat Door Models Will show the following LED’s on secondary display panel Press POWER to skip hardware diagnostics and advance to the next level...
Page 18 - Fast Test Cycle – Level Three
18 LCD Norm Fast Deli Rinse Hardware Output ------------------------------------------------------------------------------------------- bL Off Off Off On Backlight Er Off Off On Off Element Relay (turns off after 5 seconds) Ld Off Off On On Lid Motors (will run for 10 seconds) dd Off On Off Off Dete...
Page 19 - Continuous Cycle Test Mode – Level Four
19 Once the fast test cycle is selected, the DishDrawer™ goes into standby mode and 8 minutes will be showing on the display. The test cycle is started by pressing START/PAUSE , and the following components are run during the 8 minute cycle that follows: - Lid motors, fill valve, wash motor, element...
Page 20 - WIRING DIAGRAM