Page 2 - FieldServer Technologies; TABLE OF CONTENTS; Provided by the Supplier of 3; Required 3; Required 3; Reading Drum_Count_Preset data from contiguous PLC data memory
FS-8700-31 Siemens TIWAY I Index FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] TABLE OF CONTENTS 1. Siemens TIWAY I Driver Description..................
Page 4 - Siemens TIWAY I Driver Description
FS-8700-31 Siemens TIWAY I Page 1 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] 1. Siemens TIWAY I Driver Description The Siemens TIWAY I drive...
Page 5 - The BDLC protocol has to be selected on any 3
FS-8700-31 Siemens TIWAY I Page 2 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] listed under the Supported Host Adaptor Commands and Primitives...
Page 6 - Hardware Connections; The FieldServer is connected to the SCADA system as shown below.; Connection Tips / Hints; To be updated from testing feedback.; Configuring the FieldServer as a TIWAY Client; instruction Configuration mM
FS-8700-31 Siemens TIWAY I Page 3 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] 3. Hardware Connections The FieldServer is connected to the SCA...
Page 7 - Client Side Connection Descriptions
FS-8700-31 Siemens TIWAY I Page 4 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] the data required from the servers needs to be mapped in the “C...
Page 8 - Related
FS-8700-31 Siemens TIWAY I Page 5 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] Example // Client Side Connections Connections Port, Protocol, ...
Page 9 - Driver Related Map Descriptor Parameters; Map Descriptors
FS-8700-31 Siemens TIWAY I Page 6 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] 4.4.2. Driver Related Map Descriptor Parameters Section Title M...
Page 10 - Parameters
FS-8700-31 Siemens TIWAY I Page 7 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] Loop_Output 24-bit datatypes Word_Force Packed-bit datatypes Di...
Page 11 - Reading TIWAY data map descriptor examples
FS-8700-31 Siemens TIWAY I Page 8 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] 4.4.4. Reading TIWAY data map descriptor examples 4.4.4.1. Read...
Page 12 - secondary PLC status
FS-8700-31 Siemens TIWAY I Page 9 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] Preset_Step_List, Scan_Interval 5 8 9 33 49, 0s The above map d...
Page 13 - Writing TIWAY data map descriptor examples
FS-8700-31 Siemens TIWAY I Page 10 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] The above map descriptor will continuously read the three stat...
Page 15 - TIWAY host adapter command map descriptor examples
FS-8700-31 Siemens TIWAY I Page 12 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] 2, 33 49, 0s The above map descriptor will continuously write ...
Page 16 - Report Adapter Configuration; Report Network Manager Configuration
FS-8700-31 Siemens TIWAY I Page 13 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] The above map descriptor will continuously execute the indicat...
Page 17 - Reset
FS-8700-31 Siemens TIWAY I Page 14 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] C40_REP_NM_CONFIG, Nm_Config, 0, RDBC, PLC_01, Report_NM_Confi...
Page 18 - Adapter
FS-8700-31 Siemens TIWAY I Page 15 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] 4.4.6.6. Reset Adapter Forces the UNILINK Host Adapter to do a...
Page 20 - Configuring the FieldServer as a TIWAY Server; instruction Configuration mM; Server Side Connection Descriptors
FS-8700-931 Siemens TIWAY I Page 17 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] 5. Configuring the FieldServer as a TIWAY Server For a detail...
Page 22 - Specific; Driver Specific Map Descriptor Parameters
FS-8700-931 Siemens TIWAY I Page 19 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] 5.3. Server Side Map Descriptors 5.3.1. FieldServer Specific ...
Page 24 - Serving TIWAY data map descriptor example
FS-8700-31 Siemens TIWAY I Page 21 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] 5.3.3. Serving TIWAY data map descriptor example Map_Descripto...
Page 25 - Troubleshooting tips
FS-8700-31 Siemens TIWAY I Page 22 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] 6. Advanced Topics None. 7. Driver Notes None. 8. Troubleshoot...
Page 26 - Revision History
FS-8700-31 Siemens TIWAY I Page 23 of 23 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web :www.fieldserver.com Tel : (408) 262-2299 Fax : (408) 262-9042 Toll_Free : 888-509-1970 email : [email protected] Revision History Date Driver Version Document Revision Resp Co...