Page 4 - WARNING; RANGEHOOD COMPONENTS
Version 04/05 - Page 4 For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood's exhaust opening as po...
Page 5 - DUCTED; INSTALLATION DIMENSIONS
Version 04/05 - Page 5 DUCTED INSTALLATION DIMENSIONS The Tratto chimneys are adjustable and designed to meet varying ceiling heights as indicated in FIGURE 4A . The chimneys can be adjusted for ceilings between 7' 4 3/8" and 8' 9 3/8" depending on the distance between the bottom of the hood...
Page 6 - DUCTLESS; FIGURE 4B
Version 04/05 - Page 6 DUCTLESS INSTALLATION DIMENSIONS upper chimney cover ductless lower chimney cover canopy x = distance from hood to cooktop (varies depending on installation) min - 24”, suggested max - 30” cabinet base 10" min 16 1/8” max 21 1/4" 2" 36” 19 3/8" x also consult c...
Page 7 - (as indicated in FIGURE 5A
Version 04/05 - Page 7 PREPARE THE WALL 1. Disconnect and move freestanding range from cabinet open- ing to provide easier access to rear wall. Put a thick, protective covering over cooktop, set-in range or countertop to protect from damage or dirt. 2. Determine and clearly mark with a pencil the ce...
Page 10 - AVERTISSEMENT
Version 04/05 - Page 10 FIGURE 1 PLAN DE LʼINSTALLATION Cette hotte peut être installée avec ou sans conduit. La sortie dʼair peut sʼeffectuer par le mur ou le plafond. Pour une ventilation par le mur, un coude 90 o est utilisé. Lorsque installé sans conduit, la ventilation s'effective par une grill...
Page 11 - DIMENSIONS DʼINSTALLATION AVEC CONDUIT; X en FIGURE 4A
Version 04/05 - Page 11 DIMENSIONS DʼINSTALLATION AVEC CONDUIT couvercle cheminée supérieure couvercle cheminée inférieure hotte x = distance entre la hotte et la table de cuisson min - 24 po, suggested max - 30 po FIGURE 4A INSTALLATIONS AVEC CONDUIT 5 1/8 po min 16 1/8 po max 21 1/4 po 2 po 36 po ...
Page 12 - DIMENSIONS DʼINSTALLATION SANS CONDUIT; X en FIGURE 4B
Version 04/05 - Page 12 DIMENSIONS DʼINSTALLATION SANS CONDUIT couvercle cheminée supérieure couvercle cheminée inférieure sans conduit hotte x = distance entre la hotte et la table de cuisson min - 24 po, suggested max - 30 po FIGURE 4B INSTALLATIONS SANS CONDUIT 10 po min 16 1/8 po max 21 1/4 po 2...
Page 14 - INSTALLATIONS SANS CONDUIT
Version 04/05 - Page 14 INSTALLATIONS SANS CONDUIT Les installations sans conduit requièrent le Kit Pour Conver- sion Du Conduit ( FIGURE 8) . N'utilisez pas le REGISTRE ROND (H de la FIGURE 1) pour les Installations sans conduit. Le couvercle de CHEMINÉE INFÉRIEURE SANS LES TROUS (B de la FIGURE 1)...