Faber M1600 - Manuals
Faber M1600 – Manual in PDF format online.
Manuals:
Manual Faber M1600
Summary
© 2007 DALSA All information provided in this manual is believed to be accurate and reliable. No responsibility is assumed by DALSA for its use. DALSA reserves the right to make changes to this information without notice. Reproduction of this manual in whole or in part, by any means, is prohibited w...
Genie Monochrome Series-GigE Vision Camera Contents • 1 Contents GENIE MONOCHROME SERIES OVERVIEW ..................................................................................... 5 D ESCRIPTION ........................................................................................................
Genie Monochrome Series-GigE Vision Camera Genie Monochrome Series Overview • 5 Genie Monochrome Series Overview Description The Genie monochrome camera family form a series of affordable, easy to use digital cameras specifically engineered for industrial imaging applications. Genie cameras combine ...
6 • Genie Monochrome Series Overview Genie Monochrome Series-GigE Vision Camera Genie Application Advantages • Compact, rugged design • GigE Vision 1.0 compliant • Gigabit Ethernet (GigE) interconnection to a computer via standard CAT5e or CAT6 cables • Connection to the host computer NIC through a ...
Genie Monochrome Series-GigE Vision Camera Genie Monochrome Series Overview • 7 Product Part Numbers This manual covers the five monochrome Genie models summarized below. See " Camera Performance Specifications " on page 8 for each Genie model. Camera Sensor Size Resolution Pixel size (µm) f...
8 • Genie Monochrome Series Overview Genie Monochrome Series-GigE Vision Camera Camera Performance Specifications Specifications for each available sensor are listed after the general Genie camera specifications. Camera Controls Synchronization Modes Free running and Triggered Synchronous and Reset ...
Genie Monochrome Series-GigE Vision Camera Genie Monochrome Series Overview • 9 Certifications CE EN55022, class A, Radio Disturbance Characteristics EN61000-4-2, Electrostatic discharge immunity test EN61000-4-3, Radiated, radio-frequency, electromagnetic field immunity test EN61000-4-4, Electrical...
10 • Genie Monochrome Series Overview Genie Monochrome Series-GigE Vision Camera Genie M640-1/2 Specifications Item / Feature Specification Imager Format Full frame interline CCD area scan with square pixel Sensor Sony ICX414AL Resolution 640 x 480 pixels Minimum Frame Rate (free-running) 0.1 fps (o...
12 • Genie Monochrome Series Overview Genie Monochrome Series-GigE Vision Camera Genie M1024 Specifications Item / Feature Specification Imager Format Full frame interline CCD area scan with square pixel Sensor Sony ICX204AL Resolution 1024 x 768 pixels Minimum Frame Rate (free-running) 0.1 fps (one...
Genie Monochrome Series-GigE Vision Camera Genie Monochrome Series Overview • 13 Genie M1400 Specifications Item / Feature Specification Imager Format Full frame interline CCD area scan with square pixel Sensor ICX267AL Resolution 1360 x 1024 pixels Minimum Frame Rate (free-running) 0.1 fps (one fra...
14 • Genie Monochrome Series Overview Genie Monochrome Series-GigE Vision Camera Genie M1600 Specifications Item / Feature Specification Imager Format Full frame interline CCD area scan with square pixel Sensor Sony ICX274AL Resolution 1600 x 1200 pixels Minimum Frame Rate (free-running) 0.1 fps (on...
Genie Monochrome Series-GigE Vision Camera Genie Monochrome Series Overview • 15 Application Development Overview Sapera LT Library with optional Processing Sapera LT is a powerful development library for image acquisition and control. Sapera LT provides a single API across current and future DALSA ...
Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 17 Installing the Genie Camera Warning! (Grounding Instructions) Static electricity can damage electronic components. Please discharge any static electrical charge by touching a grounded surface, such as the metal computer chas...
18 • Installing the Genie Camera Genie Monochrome Series-GigE Vision Camera Using Genie with a VLAN Ethernet Switch An Ethernet switch supporting VLAN (Virtual Local Area Network) allows multiple isolated subnets to exist on the same switch. Within each VLAN group, the Genie camera and controlling c...
Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 19 Installation Overview • Inspect all cables and connectors prior to their use. Do not use faulty cables or connectors to avoid camera damage. • Before connecting power to the camera, test all power supplies. Power supplies mu...
20 • Installing the Genie Camera Genie Monochrome Series-GigE Vision Camera Genie CD Package Installation The Genie Framework software package and Sapera runtime provides all components required to control the Genie with the supplied CamExpert tool. Genie Framework software components include the Ne...
Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 21 Connect the Genie Camera Connect a power supply to the Genie camera and an Ethernet cable from the Genie to the host computer. Once communication with the host computer is started the automatic IP configuration sequence will...
22 • Installing the Genie Camera Genie Monochrome Series-GigE Vision Camera Status LED Codes The camera is equipped with a LED to display the operational status of the camera. When more than one condition is active, the LED color indicates the condition with the highest priority (such as an acquisit...
Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 23 Typical LED States on Power Up The following LED sequence occurs when the Genie is powered up connected to a network with installed Genie Framework software. Red power connected Flashing Blue waiting for IP Blue IP assigned ...
24 • Installing the Genie Camera Genie Monochrome Series-GigE Vision Camera In the event that the device is physically connected, but the Sapera GigE Server icon is indicating that the connected device is not recognized, click Scan Network to restart the discovery process. Note that the GigE server ...
Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 25 Select NIC Advanced Configuration Properties • From the Start menu go to Settings • Control Panel • Network Connections and select the NIC used to connect the Genie to. • Open the Properties for the Ethernet GigE NIC used wi...
Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 27 The Network Configuration Tools allows you to: • Configure the Windows firewall exception list • Activate the Network Imaging driver use for image acquisition on any NIC • Configure the NIC and camera IP settings Updating Ge...
Genie Monochrome Series-GigE Vision Camera Installing the Genie Camera • 29 Quick Test with CamExpert When the Genie camera is directly connected to a Gigabit network adapter on a host computer or via a network switch, testing the installation with CamExpert is a straightforward procedure. • Start S...
30 • Installing the Genie Camera Genie Monochrome Series-GigE Vision Camera About the User-Defined Camera Name The Genie can be programmed with a user-defined name to aid identifying multiple cameras connected to the network. For instance, on an inspection system with 4 cameras, the first camera mig...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 31 Operational Reference Camera and Sensor Information Camera and sensor information can be retrieved via a controlling application. Parameters such as camera model, firmware version, sensor characteristics, etc. are read to uniquely...
32 • Operational Reference Genie Monochrome Series-GigE Vision Camera Read Only Parameters Parameter Description Device Vendor For the Genie Monochrome series, this is always DALSA. Device Model Name Displays the device model name (for example, Genie M640). Device Version Displays the device version...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 33 Camera Information via Sapera LT or GenICam Applications Sapera Genie Sapera parameters for Camera and Sensor Information: Interface = {GigE Vision} DeviceVendorName = “DALSA” DeviceModelName = “Genie M640” for Genie M640 DeviceVe...
34 • Operational Reference Genie Monochrome Series-GigE Vision Camera Sensor Controls Genie provides a number of sensor controls to optimize image acquisitions for most imaging solutions. Following is an overview of the CamExpert controls displaying this information, followed by individual control f...
36 • Operational Reference Genie Monochrome Series-GigE Vision Camera Gain and Black Level Controls The Genie series of monochrome cameras provide gain and black level adjustments for the analog signal from each CCD pixel, before the analog to digital conversion. The software gain and black level co...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 37 Partial Scan—Window ROI Partial Scan (vertical cropping) The Partial Scan mode, also know as vertical cropping, reduces the number of video lines grabbed for a frame. By not scanning the full vertical area of the sensor, the maxim...
38 • Operational Reference Genie Monochrome Series-GigE Vision Camera Partial Scan (horizontal cropping) Genie also can crop the acquisition horizontally by grabbing less pixels on each horizontal line. Additionally a horizontal offset value will start the grab from any pixel count, as shown in the ...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 39 Window ROI Control via Sapera LT or GenICam Applications Sapera Genie Sapera parameters for Partial Scan and Window ROI: Width = Buffer width in pixels Height = Buffer height in lines OffsetX = Horizontal Offset in pixels of the l...
40 • Operational Reference Genie Monochrome Series-GigE Vision Camera CamExpert Image Buffer and ROI Parameters CamExpert provides controls to configure acquisitions via the Image Buffer and ROI Parameters tab. The image buffer can be easily cropped as desired. Below is the CamExpert dialog and para...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 41 Binning Binning is the process where the charge on two (or more) adjacent pixels is combined. This results in increased light sensitivity since there is twice the sensor area to capture photons. The sensor spatial resolution is re...
42 • Operational Reference Genie Monochrome Series-GigE Vision Camera Binning Control via Sapera LT or GenICam Applications Sapera Genie Sapera parameters for Binning: BinningHorizontal = {Disabled = 1, 2 pixels = 2} BinningVertical = {Disabled = 1, 2 lines = 2} In CamExpert, these parameters are av...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 43 Exposure Controls Exposure Control modes define the method and timing of how to control the sensor integration period. The integration period is the amount of time the sensor is exposed to incoming light before the video frame dat...
44 • Operational Reference Genie Monochrome Series-GigE Vision Camera External Trigger Programmable Exposure • Also known as “Edge Pre-select” exposure. See the timing diagram below. • The external trigger edge initiates the exposure process. The active external trigger edge can be selected as eithe...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 45 External Trigger Level-controlled Exposure • Also known as “Pulse Width Control” exposure. See the timing diagram below. • The external trigger edge initiates the exposure process. The active external trigger edge can be selected ...
46 • Operational Reference Genie Monochrome Series-GigE Vision Camera Synchronization Timing Genie supports two types of sensor synchronization used to align the exposure to sensor timing: • Synchronous Mode : Exposure is synchronous to the line timing of the sensor. Exposure granularity is 1µs and ...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 47 Reset Mode • Exposure starts immediately after a valid trigger. There is no jitter on the start of exposure. • Exposure time is programmable or controlled by the trigger pulse width. • Minimum exposure is 100 µs – maximum is 4 sec...
48 • Operational Reference Genie Monochrome Series-GigE Vision Camera CamExpert I/O Controls Dialog CamExpert groups the Genie I/O Controls Parameters in one group. These parameters allow configuring the Genie inputs and outputs for type of signal and signal polarity. The screen capture below shows ...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 49 General Inputs External Input Signal Opto-coupler & Debounce Circuit • Genie provides two sets of opto-coupled inputs for either RS422 or TTL signals. These can be used as external trigger sources. • See " 12-Pin Hirose Co...
50 • Operational Reference Genie Monochrome Series-GigE Vision Camera Input Controls via Sapera LT or GenICam Applications Sapera Genie Sapera parameters for Trigger Modes and General Inputs: TriggerDelayToIntegration = Delay in µs from trigger to exposure TriggerEnable = {FALSE, TRUE} TriggerSource...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 51 Strobe and General Outputs Genie provides two sets of opto-coupled outputs (see " External Outputs " on page 92 ). These can be used as a strobe signal to control lighting or to generate programmable pulses when specific e...
52 • Operational Reference Genie Monochrome Series-GigE Vision Camera When an event mode is selected, its trigger output schematic or signal timing diagram is displayed, as well as any other additional parameters for the mode. For most event modes, the trigger output signal can be set to either Acti...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 53 Pulse On Valid Trigger Event Mode The Pulse On Valid Trigger event mode generates an output signal when a valid input trigger is received. Pulse On Invalid Trigger Event Mode This event mode generates an output signal when an inva...
54 • Operational Reference Genie Monochrome Series-GigE Vision Camera Pulse On Start of Readout Event Mode The Pulse On Start of Readout event mode generates an output signal when the camera begins a readout operation from the sensor. Pulse On End of Readout Event Mode The Pulse On End of Readout ev...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 55 Pulse On End of Acquisition Event Mode The Pulse On End of Acquisition event mode generates an output signal when the acquisition process is terminated using software. Pulse On Input 1 or Input 2 Event Modes The Pulse On Input 1 o...
56 • Operational Reference Genie Monochrome Series-GigE Vision Camera Output Control via Sapera LT or GenICam Applications Sapera Genie Sapera parameters for Strobe and General Outputs. See " Accessing Features with Sapera++ LT " on page 68 . OutputSelectorOutput_x = {Open = 0, Close = 1, St...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 57 . . . . . . 0 1 2 3 252 255 254 253 255 254 253 252 2 1 0 3 Output Circuit Sensor & A/D Circuit Pixel Data Simplified Genie LUT Block Diagram (8-bit example) Programmed asInvert Function Simplified 8-bit LUT Block Diagram LUT ...
58 • Operational Reference Genie Monochrome Series-GigE Vision Camera Flat Field (Image Shading) Correction Image Shading correction, also know as Flat Field Correction is the process of eliminating small gain differences between pixels in a sensor array. That sensor when exposed to a uniformly lit ...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 59 CamExpert Flat Field Calibration Menu • Click on the Advanced Setting button to change the default number of frames averaged for each calibration step. The default value is 10 frames. • Setup the camera to capture a uniform black ...
60 • Operational Reference Genie Monochrome Series-GigE Vision Camera Using Flat Field Correction From the CamExpert menu bar enable Flat Field correction ( Pre-Processing • Flat Field Correction • Hardware ). Now when doing a live grab or snap, the incoming image is corrected by the current flat fi...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 61 Image Flip Horizontal The Genie supports a software controlled horizontal flip function as shown in the following figure. The process is done in hardware with no loss of acquisition frame rate. Horizontal Flip Vertical As shown in...
62 • Operational Reference Genie Monochrome Series-GigE Vision Camera Internal Image Test Patterns The Genie camera includes a built in test pattern generator that can be used to confirm camera Ethernet connections or driver installations, without the need for a camera lens or proper lighting. The p...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 63 Test Image Select via Sapera LT or GenICam Applications Sapera Genie Sapera parameters for Image Test Patterns: TestImageSelector = {Off = 0, Grey Horizontal Ramp = 1, Grey Vertical Ramp = 2, Grey Diagonal Ramp Moving = 3, Purity ...
64 • Operational Reference Genie Monochrome Series-GigE Vision Camera Acquisition Device Event Name (case sensitive strings) Description Start of Trigger Trigger is valid based on the programmed trigger parameters Start of Exposure Exposure has started End of Exposure Exposure is complete Feature Va...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 65 Network Controls & GigE Vision Parameters This section describes how to optimize the network configuration for maximum Genie bandwidth. Optimization of these parameters is highly dependent on the number of cameras connected to...
66 • Operational Reference Genie Monochrome Series-GigE Vision Camera Parameter Description Network Configuration Mode Specifies the Network Configuration Mode as either Automatic, Manual, or Optimize. In general use Optimize mode. Some computers, especially laptops, may require manual optimization ...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 67 Genie Power-up Configuration On power up the Genie camera initializes to a factory default state which sets the camera with neutral parameters and in free run mode. The default state ensures that the camera is ready for acquisitio...
68 • Operational Reference Genie Monochrome Series-GigE Vision Camera Power-up Control via Sapera LT or GenICam Applications Sapera Genie Sapera parameters for Power-up Configuration: Power-upConfig = {Factory Default = 0, Camera Configuration 1 = 1} SaveCameraConfigurationSelector = {Camera Configu...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 69 Feature Type STRING Feature Name Access Type Value Server Name RO STRING Genie_M640_1 ( example ) Number of Features RO STRING ( number dependent on firmware version ) DeviceVendorName RO STRING DALSA DeviceModelName RO STRING Gen...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 71 Feature Type INT32 The feature list for type INT32 has an additional column 'Exponent' which defines the feature's native unit. This exponent value is used as a unit multiplier so that the feature value is expressed as an integer,...
72 • Operational Reference Genie Monochrome Series-GigE Vision Camera Note 1: not displayed in CamExpert; not saved in a camera configuration file (CCF) Feature Type BOOL Feature Name Access Type Value LUTEnable RW BOOL True/False TriggerEnable RW BOOL True/False TriggerSoftware RW BOOL True/False F...
Genie Monochrome Series-GigE Vision Camera Operational Reference • 73 Trigger Enable - TRUE Software Input 1 Input 2 Frame Rate Trigger Delay to Integration Exposure Alignment Synchronous Reset Exposure Mode Programmable Pulse Controlled Exposure Mode Programmable Exposure Time Exposure Time TRUE Tr...
74 • Operational Reference Genie Monochrome Series-GigE Vision Camera Output Selector Output X Selector Output X Pulse Delay Output X Pulse Duration Output X Polarity Output X Pulse Delay Output X Pulse Duration Output X Polarity Open Close Strobe On: Start of Exposure Pulse On: Valid Trigger Pulse ...
Genie Monochrome Series-GigE Vision Camera Network Tools • 77 Network Tools IP Configuration Mode Details The following descriptions provide more information on the IP configuration modes supported by Genie. In general automatic IP configuration assignment is sufficient for most Genie installations....
78 • Network Tools Genie Monochrome Series-GigE Vision Camera DHCP (Dynamic Host Configuration Protocol) • This Genie IP configuration mode requires a DHCP server to allocate an IP address dynamically. The Genie must be configured to have DHCP enabled. This is the factory default settings. • The DHC...
Genie Monochrome Series-GigE Vision Camera Network Tools • 79 Network Configuration Tool The Network Configuration tool provides information on all network adapters installed in the system and any connected GigE Vision devices. For the Genie, the tool allows a simple method to assign a User-Defined ...
80 • Network Tools Genie Monochrome Series-GigE Vision Camera Genie IP Configuration System Information and Configuration Select the system icon (the computer symbol) in the left pane to display current system information which may be required when documenting Genie installations. There are no user ...
Genie Monochrome Series-GigE Vision Camera Network Tools • 81 Network Card Information and Configuration Select a network card icon in the left pane to see the NIC configuration parameters. The Network Configuration tool ensures that no two NIC devices installed in the computer are on the same subne...
82 • Network Tools Genie Monochrome Series-GigE Vision Camera After installation, all system NIC devices have the Sapera Network Imaging driver enabled. Only the NIC connected to a Genie camera requires the Network Imaging driver enabled to capture images from Genie. The Network Imaging driver strea...
Genie Monochrome Series-GigE Vision Camera Network Tools • 83 • If the camera requires a persistent IP address, select the bullet to assign a persistent IP immediately with recovery. Enter the new IP address and click on Recover Camera. Important: Any changes made with this tool will update the Geni...
84 • Network Tools Genie Monochrome Series-GigE Vision Camera Status Window Description User Name User assigned identification Manufacturer Manufacturer for this device Model GigE Vision device model Serial Number Device serial number Firm Ver Device firmware revision number MAC adddress Device MAC ...
Genie Monochrome Series-GigE Vision Camera Sapera CamExpert Guide • 85 Sapera CamExpert Guide Using CamExpert with Genie Monochrome Cameras CamExpert is the camera interfacing tool supported by the Sapera library. When used with a Genie camera, CamExpert allows a user to test all Genie operating mod...
86 • Sapera CamExpert Guide Genie Monochrome Series-GigE Vision Camera CamExpert Panes The CamExpert application uses 5 windows to simplify choosing and configuring camera files or acquisition parameters for the installed device. • Device pane : View and select from any installed Sapera acquisition ...
Genie Monochrome Series-GigE Vision Camera Sapera CamExpert Guide • 87 • Control Buttons : The Display pane includes CamExpert control buttons. These are: Acquisition control button: Click once to start live grab, click again to stop. Single frame grab: Click to acquire one frame from device. Softwa...
Genie Monochrome Series-GigE Vision Camera Technical Specifications • 89 Technical Specifications Mechanical Specifications The figure below defines the Genie family mechanical specifications. Additional notes follow.
90 • Technical Specifications Genie Monochrome Series-GigE Vision Camera Notes: Genie supports a screw lock Ethernet cable (see " Ruggedized RJ45 Ethernet Cables " on page 97 ). For information on Genie lens requirements see " Optical Considerations " on page 93 . Lens flange focal d...
Genie Monochrome Series-GigE Vision Camera Technical Specifications • 91 Genie Signal Electrical Details • Power Supply (pin 2) : +12V DC nominal. Operating tolerance +10% to –10%. Over voltage and reverse voltage protection circuit built in. The protection circuit is reset by shutting down or disco...
92 • Technical Specifications Genie Monochrome Series-GigE Vision Camera External Outputs • Programmable output mode such as strobe, event notification, etc. (see " Output Control via Sapera LT or GenICam Applications " on page 56 ). OUT+ OUT- Genie side User side Hirose-12 Connector pins NE...
Genie Monochrome Series-GigE Vision Camera Technical Specifications • 93 Camera Status LED The Genie has one multicolor LED to provide a simple visible indication of the operational status of the camera. When more than one condition is active, the LED color indicates the condition with the highest p...
94 • Technical Specifications Genie Monochrome Series-GigE Vision Camera • Some light sources age such that over their life span they produce less light. This aging may not be uniform—a light source may produce progressively less light in some areas of the spectrum but not others. Filters CCD camera...
Genie Monochrome Series-GigE Vision Camera Technical Specifications • 95 Example: An acquisition system has a 512 x 512 element, 10 μ m pixel pitch area scan camera, a lens with an effective focal length of 45mm, and requires that 100 μ m in the object space correspond to each pixel in the image sen...
96 • Technical Specifications Genie Monochrome Series-GigE Vision Camera Cleaning the Sensor Window Even with careful handling, the sensor window may need cleaning. The following steps describe various cleaning techniques to clean minor dust particles to accidental finger touches. • Use compressed a...
Genie Monochrome Series-GigE Vision Camera Technical Specifications • 97 Ruggedized RJ45 Ethernet Cables Components Express Inc. has available an industrial RJ45 CAT6 cable that on one end has a molded shroud assembly with top/bottom thumbscrews, while the other end has a standard RJ45. This cable i...
98 • Technical Specifications Genie Monochrome Series-GigE Vision Camera Computer Requirements for Genie Cameras The following information is a guide to computer and networking equipment required to support the Genie camera at maximum performance. The Genie camera series complies with the current IP...
Genie Monochrome Series-GigE Vision Camera Technical Specifications • 99 Ethernet to Fiber-Optic Interface Requirements In cases of camera-to-PC separations of more than 100 meters but an Ethernet switch is not desired, a fiber-optic media converter can be used. The FlexPoint GX from Omnitron System...
100 • Technical Specifications Genie Monochrome Series-GigE Vision Camera EC & FCC Declaration of Conformity
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 101 Troubleshooting Overview In rare cases an installation may fail or there are problems in controlling and using the Genie camera. This section highlights issues or conditions which may cause installation problems and additionally provid...
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 103 Installation Issues and Functional Problems This section covers issues indicated by the GigE server tray icon shows a warning symbol. GigE Server Warning Example 1a: IP error with multiple NICs The screenshot below shows an IP conflict...
104 • Troubleshooting Genie Monochrome Series-GigE Vision Camera GigE Server Warning Example 1b: IP error with multiple NICs As a second example, the screenshot below shows an IP conflict error similar to the example above but the second NIC has no camera connected (or only an Ethernet switch). • Th...
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 105 GigE Server Warning Example 2: Subnet Mask or IP error The screenshot below shows that the Genie device is not accessible. This IP error is an example of the Genie being assigned a persistent IP address with an incorrect subnet mask. •...
106 • Troubleshooting Genie Monochrome Series-GigE Vision Camera • Information about the CorSnid driver is also available from Network Configuration tool. Device Available with Operational Issues This section considers issues with cabling, Ethernet switches, multiple cameras, and camera exposure. Fi...
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 107 Power Failure During a Firmware Update–Now What? Don't panic! There is far greater chance that the host computer OS is damaged during a power failure than any permanent problems with the Genie. When electrical power returns and the hos...
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 109 Test a Genie Using Internal Test Patterns The Genie test pattern mode allows quick verification of an installation without the need for correct lighting or lens. Troubleshooting physical connection issues or communication problems is m...
110 • Troubleshooting Genie Monochrome Series-GigE Vision Camera Grab Remains Black While using CamExpert to test a Genie installation, there are no obvious installation problems. But when Grab is clicked in CamExpert, a grab failure occurs. The grab remains black and an Abort message is displayed. ...
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 111 Grab has Random Bad Data or Noise – Case 2 • This problem has been seen with network adapters using the Realtek RTL8169 chip and associated low-level driver. In this case the NIC reports a false maximum jumbo frame size. • In the NIC c...
112 • Troubleshooting Genie Monochrome Series-GigE Vision Camera Configuration Recommendations with Laptops • In the NIC configuration, keep the jumbo frame size set to the maximum allowed. See " Increasing Adapter Buffers and Jumbo Frames " on page 24 . • If VPN software is installed, most ...
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 113 Problems with Disconnecting NICs Genie cameras installed in environments with physical motion, vibrations, or high EMI may be disconnected by the NIC. The following items need to be reviewed to solve the problem. • Motion or vibrations...
114 • Troubleshooting Genie Monochrome Series-GigE Vision Camera Camera Exposure Issues No camera exposure when expected. • Verify by using the camera in free-running mode. Do not use external trigger mode when testing a camera setup. • If using free-running mode, verify that the exposure period is ...
Genie Monochrome Series-GigE Vision Camera Troubleshooting • 115 Verifying Network Parameters DALSA provides the Network Configuration tool to verify and configure network devices and the Genie network parameters. See section " Network Configuration Tool " on page 79 if there were any proble...
Genie Monochrome Series-GigE Vision Camera DALSA Contact Information • 117 DALSA Contact Information Genie Sales Information Visit our web site: http://www.imaging.com/ Email: mailto:[email protected] International/Canada DALSA — Montreal office 7075 Place Robert-Joncas Suite #142 St. Laurent, Q...
118 • DALSA Contact Information Genie Monochrome Series-GigE Vision Camera Genie Technical Support Any support question or request can be submitted via our web site: Technical support form via our web page: Support requests for imaging product installations, Support requests for imaging applications...
Genie Monochrome Series-GigE Vision Camera Glossary of Terms • 119 Glossary of Terms ARP Address Resolution Protocol provides a way to retrieve the MAC address associated to an IP address. Bandwidth Describes the measure of data transfer capacity. CAT5e Ethernet cable Category 5e was designed for tr...
Genie Monochrome Series-GigE Vision Camera Index • 123 Index 1 12-pin male Hirose connector, 90 8 8/10-bit LUT, 56 A Acquisition events, 63 administrator, 19 AUTORUN, 19, 20 B back focal length, 94 Binning, 41 binning modes, 41 C cable mating connector, 90 camera configuration, 32 camera interfacing...
Faber Manuals
-
Faber CADRA NOVA
Manual
-
Faber PRS20
Manual
-
Faber Remote Blower
Manual
-
Faber MR-16
Manual
-
Faber FEELING
Manual
-
Faber 620000364
Manual
-
Faber 620000041
Manual
-
Faber M640
Manual
-
Faber SP4
Manual
-
Faber 1200 CFM
Manual
-
Faber SILENCE
Manual
-
Faber M1024
Manual
-
Faber 620000370
Manual
-
Faber WHISPER
Manual
-
Faber MISTY
Manual
-
Faber SPECTRA NOVA
Manual
-
Faber MR-11
Manual
-
Faber M1400
Manual
-
Faber 630006459
Manual
-
Faber 630006506
Manual