Page 2 - Instrucciones de seguridad • Español; 安全须知; 注意
This symbol is intended to alert the user of important operating and mainte-nance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk ...
Page 3 - FCC Class B Notice; Reorient or relocate the receiving antenna.; Conventions Used in this Guide; associated equipment.; Specifications Availability; Product specifications are available on the Extron website,; Copyright; © 2012 Extron Electronics. All rights reserved.; Trademarks
FCC Class B Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, u...
Page 5 - Contents; Introduction; Controlling Multiple Amplifiers with One; References; XTRA Series • Contents
Contents Introduction ................................................. 1 About this Manual ........................................... 1 Terms Used in this Manual ........................... 1 Features ........................................................... 1 Installation .........................
Page 7 - About this Manual; Terms Used in this Manual; Features; connections with 22 AWG to 12 AWG speaker cables.; XTRA Series • Introduction
Introduction About this Manual This manual contains information about the Extron XTRA Series of power amplifiers. • XPA 1002 two-channel stereo audio power amplifier • XPA 2001-70V mono audio power amplifier • XPA 2001-100V mono audio power amplifier Terms Used in this Manual The terms “amplifier” a...
Page 9 - Installation; ” on page; Application Examples; U S; ON; XPA 1002 Application Example; XTRA Series • Installation
Installation This section discusses how to install the XTRA Series of audio power amplifiers. Topics that are covered, include: • Application Examples • Mounting the XPA 1002 and XPA 2001 WARNING: Failure to follow these instructions may result in serious injury. Installation and service must be per...
Page 10 - ST; XPA 2001 Series Application Example; Tabletop Use; equipment in a rack.; Elevated operating ambient —; If installed in a closed or multi-unit rack assembly,; Reduced air flow —; Installation of the equipment in a rack should be such that the
50/60 Hz 100-24 0V 0 .3A L 1 R L 2 R L 3 R L 4 R L 1 R L 2 R L 3 R L 4 R L 1 R L 2 R L 3 R L 4 R L 3 R L 4 R I NPUTS OUTPUTS CONTROL I NPUTS OUTPUTS RES ET ACT LINK RS-232 1 2 3 4 1 5 6 7 8 1 9 10 11 12 1 2 2 2 CO MP UTE R IN CO MP UTE R O UT VID EO IN S-V IDE O IN OU T OU T CO MP UTE R VID EO S-V I...
Page 11 - Mechanical loading —; Mounting of the equipment in the rack should be such that a; Circuit overloading —; Consideration should be given to the connection of the; Rack Mounting; If feet were installed on the bottom of the amplifier, remove them.; Rack Mounting of the Amplifier; through
3. Mechanical loading — Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. 4. Circuit overloading — Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of...
Page 12 - Rack Mounting Ventilation Recommendations; Front Panel Features and Operation; Flexible Conduit Adapter Kit Installation; An ALL-POLE MAINS SWITCH with a contact separation of at least; UL Requirements; One EMT adapter plate
Rack Mounting Ventilation Recommendations Excessive heat can decrease the optimal lifetime of the power amplifier. An over temp indicator LED on the front panel of the amplifier lights red whenever the recommended operating temperature has been exceeded. See “ Front Panel Features and Operation ” on...
Page 13 - This unit must be wired to a UL listed distribution box.; Installing the Flexible Conduit Kit; Unplug the IEC power cord from the power amplifier.; Removing the Cover
NOTE: If needed, Extron recommends using a UL-rated crimp tool to terminate the spade connectors. One recommended choice is the Molex crimp tool (Molex part #64001-0100). The kit provides a convenient means to replace the XPA’s IEC power cord with conduit, where required by local codes. WARNING: Fai...
Page 14 - Removing the IEC Connector; attached wires through the rear panel of the XPA, as shown above.; LINE; Installing the EMT Adapter Plate Assembly
100-240V 1.3 A 50-60H z Remove screws(both sides) to releaseIEC connector plate. Remove nut Blue Wire Brown Wire L N Figure 6. Removing the IEC Connector 4. Remove the ground wire nut from the grounding stud on the bottom of the enclosure, as shown above. 5. Remove the 2 screws from the IEC plate, a...
Page 15 - Operation; Power indicator LED; Green when the amplifier is receiving full power.; Rear Panel Features and Operation; Over Temp indicator LED; — This LED lights red when the amplifier exceeds the; XTRA Series • Operation
Operation This section discusses how to operate the XTRA Series of audio power amplifiers. Topics that are covered, include: • Front Panel Features and Operation • Rear Panel Features and Operation Front Panel Features and Operation XPA 1002 1 2 LIMITER/PROTECTSIGNAL OVER TEMP XPA 1002Front Panel 1 ...
Page 16 - SIGNAL; These LEDs are also located on the rear panel.
c Limiter/Protect indicator LEDs (channels 1 and 2) — These LEDs (representing output channels 1 and 2) light red under three circumstances: 1 2 LIMITER/PROTECT • When the output wiring is shorted together • When audio clipping occurs, the corresponding channel’s LED blinks once per clip occurrence....
Page 17 - AC power connector; — Connect a standard IEC AC power cord here for power; — These LEDs light red under certain circumstances.; — These LEDs light green only when an input signal is
Rear Panel Features and Operation 100-240V 0.5A, 50-60Hz XPA 2001-70V LIMITER/PROTECT SIGNAL 0 2 4 6 8 10 12 18 14 26 ∞ ATTENUATION HPF 70 V OUTPUT REMOTE INPUTS CLASS 2 WIRING G G C V L (SUMMED) R 10V 80 Hz OFF 50mA ST ANDB Y XPA 2001-70VRear Panel 1 3 4 6 2 7b 5b 8 1 1 2 LIMITER/PROTECT SIGNAL 2 S...
Page 18 - or; Bridged Mono Output; ” on
d Attenuation (channels 1 and 2) — Use a small screwdriver to adjust the audio input level for the corresponding channel. The analog potentiometers control the level from = (full attenuation) to 0 dB. NOTES: • On the XPA 2001, the single control adjusts the levels of both channels simultaneously pri...
Page 19 - Balanced or unbalanced stereo or mono audio input connector; Remote control connector; — The 3.5 mm 5-pin captive screw receptacle is used; Remote Volume Control
â Balanced or unbalanced stereo or mono audio input connector (XPA 2001) — Wire the 3.5 mm 5-pin captive screw connector for balanced or unbalanced input. Do not tin the wires! Unbalanced Mono Input Tip Sleeve LR Balanced Mono Input Tip Ring Sleeve LR Balanced Stereo Input Tip Ring Tip Ring Sleeves ...
Page 20 - Stereo audio output connector (channels 1 and 2); — Marked “1” and “2”
• Pin 5 connected to ground (pin 4) places the amplifier in standby mode. Standby mode turns off all output, although the amplifier is still receiving power. Use the included 2-pin, 3.5 mm captive screw connector to remotely ground pin 5. The power indicator LED lights amber when the amplifier is in...
Page 21 - screws on either side.; Mono audio output connector; You must use Class 2 wiring for this output to comply with UL
To wire the stereo audio output connector: Step 1: Strip and insert the speaker wires into the connector and tighten the captive screws. Be sure to observe the correct polarity. Do not tin the wires! Step 2: Insert the wired connector into the amplifier output and secure the locking screws on either...
Page 22 - High pass filter toggle switch; — Use a small screwdriver to toggle this recessed
To wire the mono audio output connector: Step 1: Strip and insert the speaker wires into the connector and tighten the captive screws. Be sure to observe the correct polarity. Do not tin the wires! Step 2: Insert the wired connector into the amplifier output and secure the locking screws on either s...
Page 23 - connected to this port.; Red; VOLUME; Pinout Diagram for VCM 100 MAAP Connection to XPA Remote
Remote Volume Control Options for remote control of the XPA amplifiers include the Extron VCM 100 and VC 50 volume controllers. Third party 10k potentiometer volume controllers can also be connected to this port. As shown in the following illustration, pin V (1) on the XPA is a 10 VDC reference volt...
Page 24 - Controlling Multiple Amplifiers with One Volume Controller; attached between the Vol/Mute and the Ground pin of the first; Regulating Multiple Amplifiers with a Single Volume Controller
Controlling Multiple Amplifiers with One Volume Controller Several XPA 1002 and XPA 2001 units can be daisy-chained so that one volume controller can simultaneously regulate the volume of all the amplifiers. NOTES: • As additional amplifiers are added to the daisy chain, the sensitivity of the volum...
Page 25 - Bridging allows power to be output in mono at 200 watts at 8 ohms.; positive; Bridging the Output of the XPA 1002
Bridged Mono Output The power output of the XPA 1002 can be effectively doubled by bridging the output. Bridging allows power to be output in mono at 200 watts at 8 ohms. NOTES: • The bridging instructions that follow apply only to the XPA 1002 model. • The minimum load impedance when bridging is 8 ...
Page 26 - Troubleshooting; Amplifier Fails to Exit Standby Mode Promptly; XTRA Series • Troubleshooting
Troubleshooting The front and rear panels have LED warning indicators, as described in the following diagnostic information. Amplifier Fails to Exit Standby Mode Promptly The input channel (channels 1 and 2) Signal LED lights green per indicated input channel when an input signal is detected. Power ...
Page 27 - Limiter/Protect LED Warning Indicators; channel as shown in the following diagnostic information.; Over Temp Indicator LED; Lights steady Amplifier has exceeded the
Limiter/Protect LED Warning Indicators The output channel (channels 1 and 2) Limiter/Protect LED lights red per indicated output channel as shown in the following diagnostic information. LED State Problem Description Problem Solution Blinks Audio clipping is occurring at the rate of one blink per cl...
Page 28 - Part Numbers and Accessories; Included parts; XPA 1002 two-channel power amplifier; Optional Accessories; Accessories; Flexible conduit adapter kit; XTRA Series • References
References This section discusses the part numbers and accessories for the XTRA Series of half-rack audio power amplifiers. Part Numbers and Accessories Included parts Included parts Replacement part number XPA 1002 two-channel power amplifier 60-849-01 or XPA 2001-70V single-channel power amplifier...
Page 29 - Extron Warranty; and Central America:; The Netherlands
Extron Headquarters+1.800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX Extron Europe+800.3987.6673 (Inside Europe Only)+31.33.453.4040 +31.33.453.4050 FAX Extron Asia+800.7339.8766 (Inside Asia Only)+65.6...