Page 2 - Precautions; FCC Class A Notice; Extron’s Warranty
Precautions This symbol is intended to alert the user of importantoperating and maintenance (servicing) instructionsin the literature provided with the equipment. This symbol is intended to alert the user of thepresence of uninsulated dangerous voltage withinthe product's enclosure that may present ...
Page 3 - TSC 100 • Quick Start Guide; Turn all of the equipment off; Rack mount the TSC 100; Attach output and loopout cables; Connect power cords and turn on the equipment; Quick Start Guide — TSC 100
TSC 100 • Quick Start Guide QS-1 To install and set up the TSC 100, follow these steps: Step 1 Turn all of the equipment off and disconnect it from the power source. Step 2 Rack mount the TSC 100 , or place it on a desktop. See “Rack Mounting the TSC 100” in chapter 2, Installation and Operation. St...
Page 4 - Quick Start Guide — TSC 100, cont’d; TSC 100 • Table of Contents; Chapter 1 • Introduction; Table of Contents; Select an input and an output standard; The picture should now appear; Optimizing the Video
TSC 100 • Quick Start Guide Quick Start Guide — TSC 100, cont’d i TSC 100 • Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About the TSC 100 ................................................................. 1-2 Features ........................
Page 5 - Table of Contents, cont’d; Chapter One; Introduction; Features
ii TSC 100 • Table of Contents Table of Contents, cont’d TSC 100 1 Chapter One Introduction About the TSC 100 Features
Page 6 - TSC 100 • Introduction; Chapter Two; Installation and Operation; Rack Mounting the TSC 100
TSC 100 • Introduction Introduction TSC 100 2 Chapter Two Installation and Operation Rack Mounting the TSC 100 Connections Operation Troubleshooting About the TSC 100 The Extron TSC 100 is a transcoder and standards converter thatallows worldwide compatibility with video standards such asNTSC 3.58, ...
Page 7 - Connections; Rear panel connections; Power connection
TSC 100 • Installation and Operation TSC 100 • Installation and Operation Installation and Operation 2-3 Connections All connections, including power, input and output, andcontrol, are on the rear panel of the TSC 100. See figure 2. RS-232/422 COMPOSITE COMPOSITE S-VIDEO S-VIDEO 1 2 POWER I NPU TS O...
Page 8 - Installation and Operation, cont’d; Operation; Front panel controls and indicators
TSC 100 • Installation and Operation TSC 100 • Installation and Operation Installation and Operation, cont’d 2-5 2-4 Software for RS-232 or RS-422 control is included with the TSC100. See chapter 3, Serial Control for details. 6 Buffered loopout composite BNC connector — Connect one BNC female conne...
Page 9 - Min / Max indicator LED; Presets; Troubleshooting
TSC 100 • Installation and Operation TSC 100 • Installation and Operation Installation and Operation, cont’d 2-6 8 Min / Max indicator LED — A red LED lights to indicate when the minimum or maximum adjustmentlevels are reached. Presets When PAL is converted to NTSC or when NTSC is converted toPAL, t...
Page 10 - TSC 100 • Installation and Operation; Chapter Three; Serial Control; Programmer’s Guide for Serial Communication
TSC 100 • Installation and Operation Installation and Operation, cont’d TSC 100 3 Chapter Three Serial Control Programmer’s Guide for Serial Communication Control Software for Windows ® 2-8
Page 11 - Serial Control, cont’d; Device-initiated messages
TSC 100 • Serial Control TSC 100 • Serial Control Serial Control, cont’d Programmer’s Guide for Serial Communication The TSC 100 can be controlled by a host computer or othercontrol device via an RS-232/422 connection with the followingprotocol: • 9600 baud • 1 stop bit • no parity • no flow control...
Page 12 - Symbol definitions; esponse table for SIS commands; Command
TSC 100 • Serial Control TSC 100 • Serial Control Serial Control, cont’d Symbol definitions = CR/LF (carriage return/line feed) • = Space X1 = Input number (1 = composite, 2 = S-video) X2 = Adjustment range (0-255) X3 = Adjustment range (0-100) X4 = 0 = on, 1 = off X5 = Video input Standard — 0 = No...
Page 14 - Control Software for Windows; Installing the software
TSC 100 • Serial Control TSC 100 • Serial Control Serial Control, cont’d 3-9 3-8 Figure 7 — Aspect Ratio Presets Control Software for Windows The included graphical control software for Windows offersanother way to control the TSC 100 via RS-232/422 in additionto the Simple Instruction Set commands ...
Page 15 - TSC 100 • Serial Control; Appendix A; and Accessories; Specifications; Using the help system
TSC 100 • Serial Control Serial Control, cont’d TSC 100 A Appendix A Specifications, Part Numbers, and Accessories Specifications Parts 3-10 2 . Click on the comm port that isconnected to the interface’s RS-232port. The control software will “lookfor” the interface at that port and readits configura...
Page 16 - Specifications, Part Numbers, and Accessories; Specifications are subject to change without notice.
TSC 100 • Specifications, Part Numbers, and Accessories TSC 100 • Specifications, Part Numbers, and Accessories Specifications, Part Numbers, and Accessories A-3 DC offset ....................................... ±5 mV maximum Sync Standards Sync input ......................... NTSC 3.58, NTSC 4.43, ...
Page 17 - TSC 100 • Specifications, Part Numbers, and Accessories; Parts; Included Parts; Accessories; Cables; Adapters
TSC 100 • Specifications, Part Numbers, and Accessories Specifications, Part Numbers, Accessories, cont’d A-4 Parts Included Parts These items are included in each order for a TSC 100: Included parts Replacement part number TSC 100 60-451-01 9 VDC, 1A external power supply 70-056-01 TSC 100 User ’s ...