Precautions This symbol is intended to alert the user of importantoperating and maintenance (servicing) instructionsin the literature provided with the equipment. This symbol is intended to alert the user of thepresence of uninsulated dangerous voltage withinthe product's enclosure that may present ...
Page 3 - RGB 400 Series Table of Contents; Chapter 1 • Introduction; DIP switches; Appendix A • Specifications; Table of Contents
i RGB 400 Series Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About this Manual ................................................................ 1-2 About the RGB 400 Series Interfaces .......................... 1-2 Features .................
Page 4 - Table of Contents, cont’d; Chapter One; Introduction; About This Manual; Appendix C • Dimensions
ii RGB 400 Series Table of Contents Table of Contents, cont’d RGB 400 Series 1 Chapter One Introduction About This Manual About The RGB 400 Series Interfaces Features Appendix C • Dimensions ........................................................ C-1 RGB 400 Panel Dimensions ..........................
Page 5 - RGB 400 Series Introduction; Chapter Two; Installation and Operation; Installation Overview; RGB 400 Series features
RGB 400 Series Introduction Introduction, cont’d RGB 400 Series 2 Chapter Two Installation and Operation Installation Overview Installation and Operation Instructions Introduction About This Manual This manual contains information about the RGB 400 Seriesinterfaces and on how to operate and configur...
Page 6 - Installation and Operation, cont’d; Determining installation location; Determine the installation location.
RGB 400 Series Installation and Operation RGB 400 Series Installation and Operation Installation and Operation, cont’d 2-3 Installation and Operation Instructions Determining installation location Take cabling and power availability and the location of wallstuds into consideration when selecting an ...
Page 7 - Attaching the wall box to wall studs
RGB 400 Series Installation and Operation RGB 400 Series Installation and Operation Installation and Operation, cont’d 2-5 Flush withWall Surface Screws or Nails Wall Stud Wall Box Attaching the wall box to wall studs To attach the wall box to wood, use four #8 to # 10wood or sheet metal screws. A m...
Page 8 - RGB 406 front and rear features; If this LED is on, power and sync pulses; Front and rear panel (circuit board) features; Extron; power and video sync pulses are present.
RGB 400 Series Installation and Operation RGB 400 Series Installation and Operation Installation and Operation, cont’d Extron RGB 406/ RGB 408 Captive Screw Connector J13 33-398-01 B 08 99 J10 J8 J9 J10 J8 J9 ON 1 = +5V 20 mA max.2 = –5V 20 mA max.3 = Ground SW1 3 2 1 1. ON = Remove serration pulses...
Page 9 - REAR; Auto power LED; RGB 402 front and rear features
RGB 400 Series Installation and Operation RGB 400 Series Installation and Operation Installation and Operation, cont’d 7 J13 jumper — Pin 1 = +5V, pin 2 = -5V, pin 3 = ground. 8 SW1 DIP switches — 1. ON = Removes serration pulses.2. ON = Enables Digital Display Sync Processing(DDSP). 9 J10 blue gain...
Page 10 - — Settings are shown on; RGB 404 front and rear features
RGB 400 Series Installation and Operation RGB 400 Series Installation and Operation Installation and Operation, cont’d 8 Pin assignment label for the audio output captive screw connector (item 9) — Audio output wiring is discussed in the cabling section of this chapter. 9 Audio output captive screw ...
Page 11 - RGB 408 front and rear features
RGB 400 Series Installation and Operation RGB 400 Series Installation and Operation Installation and Operation, cont’d 2-13 7 BNC output connectors — These 6 connectors are for video and sync output. Connect the coaxial cables’BNC connectors as shown here for red, green and blue video output, and ei...
Page 12 - RGB 400 Series gain/peaking jumpers; Setting DIP switches and jumpers; Changing jumper settings
RGB 400 Series Installation and Operation RGB 400 Series Installation and Operation Installation and Operation, cont’d Attaching adapter plates (RGB 408) The RGB 408 can have up to 4 optional adapter plates. Theadapter plates allow for a variety of types of pass-throughaudio and/or video connectors ...
Page 13 - Cabling RCA connectors; should be connected to the grounded metal wall; Installing optional adapter plates; Cabling and connections; Attaching cables to pass-through connectors; S-video connector wiring diagram
RGB 400 Series Installation and Operation RGB 400 Series Installation and Operation Installation and Operation, cont’d Cabling RCA connectors For composite video, solder the center conductor of acoaxial cable to the central solder cup of the RCA connector.Solder the cable’s shield to the grounded gr...
Page 14 - Wiring RGB 404 audio connectors; Wiring audio output captive screw connectors; Connecting audio cables — RGB 404; on two RCA input connectors (one each for left and; • Audio channel two (CH2) consists of unbalanced left and
RGB 400 Series Installation and Operation RGB 400 Series Installation and Operation Installation and Operation, cont’d signal. For example, the input signals from the left side ofchannel one (CH1L) are output as CH1L+ and CH1L-. Thefollowing illustration shows the audio inputs and outputsand how to ...
Page 15 - If the image does not appear or there is no sound; Ensure that all devices are plugged in.; Using installation cable; Below is an example of how the cable can be used.; Using installation cable with an RGB 402; Connecting audio cables — RGB 406, RGB 408; Solder and insulate the connections.
RGB 400 Series Installation and Operation RGB 400 Series Installation and Operation Installation and Operation, cont’d Pre-installation testing/troubleshooting Before installing the interface into the wall or furniture, testthe system to make sure that the connections and interfacesettings are corre...
Page 16 - Mounting the interface to the wall box; Detach the input cables from the front panel.; Installing EMI strips on the wall box; If the image does not display correctly
RGB 400 Series Installation and Operation RGB 400 Series Installation and Operation Installation and Operation, cont’d Mounting the interface to the wall box Once the system has been cabled and tested, the interfacecan be installed in the wall or furniture. 1. Remove power from the interface and inp...
Page 17 - Application diagrams; A typical RGB 406 application
RGB 400 Series Installation and Operation RGB 400 Series Installation and Operation Installation and Operation, cont’d Application diagrams Below are examples of typical system installations thatincorporate RGB 400 series interfaces. Many otherconfigurations are possible. Extron offers a variety ofl...
Page 18 - RGB 400 Series Installation and Operation; Appendix A; Specifications
RGB 400 Series Installation and Operation Installation and Operation, cont’d RGB 400 Series A Appendix A Specifications Specifications 2-26
Page 19 - Specifications, cont’d; maximum output drive; These specifications apply to all models unless otherwise noted.
RGB 400 Series Specifications RGB 400 Series Specifications Specifications, cont’d A-3 Audio input — RGB 402 Number/type .............................. 1 stereo, unbalanced (pass-through)Connectors .................................... 2 RCA female jacks Audio input — RGB 404 Number/type ...............
Page 20 - Enclosure dimensions (RGB 402 and RGB 404); Specifications are subject to change without notice.; Audio output — RGB 404 (channels 1 and 2); conductor; General; Enclosure dimensions (RGB 400 and RGB 406)
RGB 400 Series Specifications RGB 400 Series Specifications Specifications, cont’d Enclosure dimensions (RGB 402 and RGB 404) Plate .................................... 4.50” H x 6.40” W (11.43 cm H x 16.26 cm W) Box ...................................... 3.75" H x 5.3" W x 2.5" D (9.5 c...
Page 21 - RGB 400 Series Specifications; Appendix B; Templates; RGB 408 Cut-out Template
RGB 400 Series Specifications Specifications, cont’d RGB 400 Series B Appendix B Templates RGB 400 and RGB 406 Cut-out Template RGB 402 and RGB 404 Cut-out Template RGB 408 Cut-out Template A-6
Page 23 - RGB 400 Series Templates; Appendix C; Dimensions; without; mplate; Use this template for cutting a hole in a wall or
RGB 400 Series Templates Templates, cont’d RGB 400 Series C Appendix C Dimensions RGB 400 Panel Dimensions RGB 402 Panel Dimensions RGB 404 Panel Dimensions RGB 406 Panel Dimensions RGB 408 Panel Dimensions RGB 408 Panel Dimension Details B-4 The light g ra y area represents the la y out of the elec...
Page 24 - RGB 402 Panel Dimensions; RGB 400 Panel Dimensions; Extr
RGB 400 Series Dimensions RGB 400 Series Dimensions Dimensions, cont’d C-3 RGB 402 Panel Dimensions Extr on INPUT HIGH Z 75 Ohm AUTO POWER RGB 402 DET AIL B DET AIL A HAND SAND T O 0.06" RADIUS AR OUND T O P EDGES. DET AIL C DET A IL A DET AIL B SCALE: 2/1 DET AIL C (VIEWED FR OM BA CK SIDE) ST ...
Page 25 - RGB 406 Panel Dimensions
RGB 400 Series Dimensions RGB 400 Series Dimensions Dimensions, cont’d C-5 Extr on RGB 406 INPUT H. SHIFT HIGH Z 75 Ohm AUTO POWER DET AIL C HAND SAND T O 0.06" RADIUS AR OUND THE T OP OF THESE EDGES. DET A IL A DET AIL B ST ANDOFFS: 2 REQ'D ø .156 THR U WITH C'SINK ø .290 x 82 ˚ ON NEAR SIDE (4...
Page 26 - RGB 408 Panel Dimension Details; RGB 408 Panel Dimensions
RGB 400 Series Dimensions RGB 400 Series Dimensions Dimensions, cont’d RGB 408 Panel Dimension Details C-7 0.700 1.050 2.100 2.810 0.350 3.520 2.740 1.760 1.370 1.405 ø 0.170 THR U (8 PLA CES) 1.375 2.750 3.000 1.500 R 0.050 (4 PLA CES) DET AIL A ø .120 THR U , WITH ø .250 C'BORE ON BO TH SIDES, .04...
Page 27 - RGB 400 Series Dimensions; Appendix D; Accessories and Part Numbers; Interfaces and Included Parts
RGB 400 Series Dimensions Dimensions, cont’d RGB 400 Series D Appendix D Accessories and Part Numbers Interfaces and Included Parts Accessories and Connectors Cables Optional Adapter Plates C-8
Page 28 - Part Numbers and Accessories, cont’d; Part number; Part Numbers and Accessories
RGB 400 Series Part Numbers and Accessories RGB 400 Series Part Numbers and Accessories Part Numbers and Accessories, cont’d Cables Monitor breakout cables Part number MBC VGA/XGA HR 26-162-01 MBC Mac/Quadra 26-018-02 MBC Sun/Sparc HR 26-424-01 MBC SGI/13W3 HR 26-425-01 Below is a listing of some of...
Page 29 - Pre-cut high resolution cables; Optional Adapter Plates; • four adapter plates with a “plate size” of one,; Architectural adapter plates
RGB 400 Series Part Numbers and Accessories RGB 400 Series Part Numbers and Accessories Part Numbers and Accessories, cont’d D-5 s et al P r et p a d A l ar ut c et i h cr A r ot c e n n o C e p yT el g ni S n oi t pi r c s e d et al p r et p a d A et al P e zi s e p yt r ot c e n n o c t n or F e p...
Page 31 - RGB 400 Series Part Numbers and Accessories
RGB 400 Series Part Numbers and Accessories Part Numbers and Accessories, cont’d D-8