Page 2 - Precautions; Safety Instructions • English; Extron’s Warranty; will begin the repair process as quickly as possible.
Precautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may pres...
Page 3 - FCC Class A Notice; cables must be used with the unit to ensure compliance.
FCC Class A Notice Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial envir...
Page 4 - PS 123 12 VDC, 3 Amp Power Supply • Table of Contents; Table of Contents
i PS 123 12 VDC, 3 Amp Power Supply • Table of Contents i Table of Contents Introduction ..................................................................................... 1 Front and Rear Panel Features .................................................. 1 LED indicators.............................
Page 5 - Table of Contents, cont’d; PS 123 12 VDC, 3 Amp Power Supply • User's Guide; Introduction; Figure 1 — PS 123 front and rear panels
ii PS 123 12 VDC, 3 Amp Power Supply • Table of Contents Table of Contents, cont’d PS 123 12 VDC, 3 Amp Power Supply • User's Guide Introduction The Extron PS 123 is a high performance, plenum rated, DC power supply that accepts a 100 VAC to 240 VAC input and outputs 12 VDC, 3 amp maximum for the to...
Page 6 - Figure 2 — Using the conduit option for the PS 123; Connections
PS 123 12 VDC, 3 Amp Power Supply • User's Guide PS 23, cont’d 2 PS 123 12 VDC, 3 Amp Power Supply • User's Guide 3 LED indicators See the illustrations on page 1. a Power status LEDs — These front and rear panel LEDs indicate the PS 123's status by lighting as follows:• Green when power is applied ...
Page 7 - UL requirements; Figure 3 — Removing the EMT plate; Figure 4 — Removing the top cover; Use the Phillips head end of an Extron Tweeker or a small; Figure 5 — Terminal block and IEC wiring; ground wire
PS 123 12 VDC, 3 Amp Power Supply • User's Guide PS 23, cont’d PS 123 12 VDC, 3 Amp Power Supply • User's Guide W Installation and service must be performed by a qualified electrician only. C A UL listed electrical distribution box is recommended for the termination of the conduit opposite the PS 12...
Page 8 - Figure 6 — Terminal block and conduit wiring; hot; Output power — wiring the DC output connectors; SECTION A–A; POWER; Figure 7 — Power connector wiring
PS 123 12 VDC, 3 Amp Power Supply • User's Guide PS 23, cont’d PS 123 12 VDC, 3 Amp Power Supply • User's Guide 7 . From the rear panel end, pull the EMT plate (see figure 3) out of the enclosure. 8 . Thread the 18-gauge power wires through the length of the electrical conduit tube. 9 . Install the ...
Page 9 - Mounting options; Rack mounting; UL rack mounting requirements; QuarterRackStandardShelf; Figure 8 — Rack mounting the PS 123
PS 123 12 VDC, 3 Amp Power Supply • User's Guide PS 23, cont’d PS 123 12 VDC, 3 Amp Power Supply • User's Guide C Stripping the wires to expose less than the recommended amount may cause them to slide out of the connector too easily, even if they are tightly pinched by the captive screws. C Do not t...
Page 10 - Figure 9 — Under-desk mounting the PS 123; Projector mounting; Extron; Figure 10 — Projector mounting the PS 123
PS 123 12 VDC, 3 Amp Power Supply • User's Guide PS 23, cont’d 0 PS 123 12 VDC, 3 Amp Power Supply • User's Guide 2 . Mount the PS 123 on the rack shelf, using two 4-40 x 3/16" screws in opposite (diagonal) corners. 3 . If necessary, mount the half rack width false front panel (included with the...
Page 11 - The pole fits snugly into the depression in the center of; For a smaller pole; Figure 11 — Projector mounting the PS 123; Figure 12 — Components of the Extron PMK 450 kit
PS 123 12 VDC, 3 Amp Power Supply • User's Guide PS 23, cont’d 2 PS 123 12 VDC, 3 Amp Power Supply • User's Guide 3 5 . Assemble the U-bolt and the following parts in the following order (figure 11, below): a . Pass the legs of the U-bolt through the slotted holes on the mount plate flange. b . Plac...
Page 12 - FRONT; Figure 13 — Routing the cables for the PMK 450
PS 123 12 VDC, 3 Amp Power Supply • User's Guide PS 23, cont’d PS 123 12 VDC, 3 Amp Power Supply • User's Guide 4 . Ensure that the cables exit the end of the pipe and not the cable access hole. 5 . Remove any rubber feet from the bottom of the device(s) to be mounted. 6 . Secure the device(s) to th...
Page 13 - Included Parts; Included parts; Accessories; Specifications; General; Specifications are subject to change without notice.
PS 123 12 VDC, 3 Amp Power Supply • User's Guide PS 23, cont’d PS 123 12 VDC, 3 Amp Power Supply • User's Guide Included Parts These items are included in each order for a PS 123 power supply: Included parts Part number PS 123 Power Supply 60-814-01 (8) Female, 3.5 mm, 2-pole 10-702-10LF captive scr...
Page 14 - This page was intentionally left blank.
PS 123 12 VDC, 3 Amp Power Supply • User's Guide PS 23, cont’d PS 123 12 VDC, 3 Amp Power Supply • User's Guide This page was intentionally left blank. This page was intentionally left blank.