Page 2 - 安全须知; 注意
This symbol is intended to alert the user of important operating and mainte-nance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk ...
Page 3 - FCC Class A Notice; Extron Safety; ” on the Extron website.; Conventions Used in this Guide; Notifications; the following are used:; Copyright; © 2012 Extron Electronics. All rights reserved.; Trademarks
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equ...
Page 5 - Contents; Introduction; Termination and Mute Jumpering —; Installation and Operation; MTP DA4 and MTP DA8 • Contents
Contents Introduction ............................................................ 1 About the MTP DA4 and MTP DA8 ..................... 1TP Cable Advantages .......................................... 2 Transmission Distance ..................................... 2 Termination and Mute Jumpering — MT...
Page 7 - About the MTP DA4 and MTP DA8; MTP T SV; Typical TP Distribution System; MTP DA4 and MTP DA8 • Introduction
Introduction This section introduces the MTP DA4 and MTP DA8. Topics include: • About the MTP DA4 and MTP DA8 • TP Cable Advantages • Termination and Mute Jumpering — MTP 15HD Systems Only About the MTP DA4 and MTP DA8 The Extron MTP DA4 and MTP DA8 twisted pair (TP) distribution amplifiers (DAs) di...
Page 8 - The MTP DA; does not; support the remote power feature of the MTP SV and; TP Cable Advantages; Transmission Distance; The maximum distance; for the entire transmission system; is determined by the output; Video Format
NOTE: The MTP DA does not support the remote power feature of the MTP SV and VTT001. You will have to power the transmitter and all connected receivers. A contact closure connector on the rear panel provides the ability to mute individual outputs or all outputs.The MTPs ship with external desktop 12...
Page 9 - specification at 75 Hz.; MTP SV and MTP CV transmission distances; Resolutions marked with an asterisk (*) in the above table have the
Video Format Pre-Peak Off Pre-Peak On Max. Distance (High Quality) Max. Distance (Variable Quality) 1280 x 1024* <250 feet (75 m) >300 feet (90 m) 350 feet (105 m) 450 feet (135 m) 1360 x 765 <250 feet (75 m) >300 feet (90 m) 400 feet (120 m) 500 feet (150 m) 1365 x 768 <250 feet (75 ...
Page 10 - part of an MTP SV series or VTT001/VTR001 system.; Mounting; Locate jumper J3 on the main board and; Opening the DA and Termination Jumpering
Termination and Mute Jumpering — MTP 15HD Systems Only NOTE: The position of jumpers J3 and J9 have no effect when the DA is installed as a part of an MTP SV series or VTT001/VTR001 system. When an MTP T 15HD A or SW MTP T 15HD A provides the input, the MTP DA output can include analog audio as well...
Page 12 - Connections; MTP DA Rear Panel Features; Plug the included external 12 VDC power supply into this 2-pole; AV Input connector —; Connect one end of the cable carrying the video or; AV Output connector —; Connect one end of up to four or eight TP cables to these; MTP DA4 and MTP DA8 • Installation and Operation
Installation and Operation This section provides information pertaining to the installation and operation of the MTP DA4 and MTP DA8, including: • Connections • Power Supply Wiring • TP Cable Termination • Front Panel Power Indicator • Skew Delay Problems Connections ATTENTION: Do not connect these ...
Page 13 - Out All; Power Supply Wiring; Figure
NOTES: • The MTP DA output does not provide any pre-peaking control. The total recommended distance for a complex system with multiple DA outputs is the same as for a simple system with a single transmitter and receiver. • See the recommended transmission ranges in the table on page 2. The recommend...
Page 14 - TP Cable Termination; Figure 6; MTP 15HD RS Series User Guide
ATTENTION: Power supply voltage polarity is critical. Incorrect voltage polarity can damage the power supply and the unit. The ridges on the side of the cord (see figure 5 ) identify the power cord negative lead. To verify the polarity before connection, plug in the power supply with no load and che...
Page 15 - When the TP input is from a low resolution unit (MTP SV or MTP AV),
Side RJ-45 Connector 1 2 3 4 5 6 7 8 Insert Twisted Pair Wires Pins: NOTE: When the TP input is from a low resolution unit (MTP SV or MTP AV), the signal assignment depends on the position of signal jumpers in the transmitter and receiver (see the MTP AV Series User Guide ). Jumpers in Mono Position...
Page 16 - Front Panel Power Indicator; The; indicates power is applied to the MTP DA (see figure; MTP DA Front Panels; Skew Delay Problems; Switching to an Extron Enhanced Skew-Free AV UTP cable
Front Panel Power Indicator The Power LED indicates power is applied to the MTP DA (see figure 7 ). MTP DA SERIES Power LED Figure 7. MTP DA Front Panels Skew Delay Problems CAT 5 TP cable can lead to registration errors between the red, green, and blue video signals. Pair skew can be measured with ...
Page 17 - This section provides reference information, including:; Specifications; Connectors; Connectors; MTP DA4 and MTP DA8 • Reference Information
Reference Information This section provides reference information, including: • Specifications • Part Numbers • Mounting Specifications Video Gain ............................................... Unity Video input — see transmitters specifications Number/signal type ........................ 1 set of ...
Page 18 - Control/remote — distribution amplifier; control; General; Power input requirements
Control/remote — distribution amplifier Contact closure (latching) MTP DA4 ................................. (1) 3.5 mm captive screw connector, 6 pole for contact closure output mute control MTP DA8 ................................. (1) 3.5 mm captive screw connector, 10 pole for contact closure ou...
Page 19 - Part Numbers; MTP DA Distribution Amplifier; Cables
Part Numbers MTP DA Distribution Amplifier DA Part Number MTP DA4 60-685-01 MTP DA8 60-686-01 Included Parts These items are included in each order for MTP DA4 and MTP DA8: Included Parts Part Number 12 VDC power supply MTP DA4MTP DA8 28-071-57LF MTP DA Series Setup GuideIEC power cordRubber feetTwe...
Page 20 - UL Guidelines; — If installed in a closed or multi-unit rack assembly,; Tabletop Use
Connectors Connector Part Number CAT 6 jack (black), qty. 10 100-476-01 CAT 6 jack (red), qty. 10 100-477-01 CAT 6 jack (blue), qty. 10 100-478-01 CAT 6 jack (orange), qty. 10 100-479-01 CAT 6 jack (gray), qty. 10 100-480-01 CAT 6 jack (white), qty. 10 100-481-01 CAT 6 jack (ivory), qty. 10 100-482-...
Page 21 - Extron Warranty; and Central America:; USA; xtron
Contact Information Contact Information Extron Headquarters +1.800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX Extron Europe +800.3987.6673 (Inside Europe Only)+31.33.453.4040 +31.33.453.4050 FAX Extron ...