Page 2 - 安全须知; 注意
This symbol is intended to alert the user of important operating and mainte-nance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk ...
Page 3 - FCC Class A Notice; This device may not cause harmful interference.; Symbol Convention; A Note draws attention to important information.; Copyright; © 2010 Extron Electronics. All rights reserved.; Trademarks
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interferen...
Page 4 - Contents; Installing the Boards into the PowerCage; PowerCage MTP T 15HD RSA and PowerCage MTP R 15HD RSA SEQ • Contents
Contents Introduction ............................................ 1 About this Guide ............................................. 1About the PowerCage MTP 15HD RSA Transmitters and Receivers .............................. 1 Features ........................................................... 2 Ins...
Page 5 - Introduction; About this Guide; This guide contains information about the following Extron; PowerCage MTP T 15HD RSA transmitter; In this guide, the term “PowerCage MTP 15HD RSA” refers to both; About the PowerCage MTP 15HD RSA Transmitters and Receivers; PowerCage 1600 Enclosure User Guide; PowerCage MTP T 15HD RSA transmitter —; and set the DIP switches
Introduction • About this Guide • About the PowerCage ™ MTP 15HD RSA Transmitters and Receivers • Features About this Guide This guide contains information about the following Extron ® PowerCageMTP 15HD RSA modular board-designed twisted pair transmitters and receivers for the PowerCage Modular Powe...
Page 6 - PowerCage MTP R 15HD RSA SEQ receiver —; Features; Compatible with HDTV component video, bi-level or tri-level sync
The transmitter board also features EDID emulation, whereby the correct refresh rate and resolution is applied to the incoming computer signal, ensuring a proper image output display. Two DIP switches on the board allows the user to set the refresh rate to 50 or 60 Hz (default is 60 Hz) using switch...
Page 7 - PowerCage MTP T 15HD RSA; transmits high resolution video and mono audio or; PowerCage MTP R 15HD RSA SEQ r; eceives high resolution video and mono audio or
• PowerCage MTP T 15HD RSA transmits high resolution video and mono audio or RS-232 signals 600 feet (185 meters) or more over a single twisted pair cable. о Inputs: Female 15-pin HD connector for video, 5-pole captive screw connector for audio input, 3-pole captive screw connector for RS-232 commun...
Page 8 - Installing the Boards into the PowerCage Enclosure; dual slot; Inserting Boards into the PowerCage Enclosure
Installation and Operation This section describes the installation and operation of the PowerCage MTP T 15HD RSA and MTP R 15HD RSA SEQ, including: • Installing the Boards into the PowerCage Enclosure • Board Connections, LEDs, and Rear Panel Features • PowerCage Front Panel Port, Control, and Indic...
Page 9 - Board Connections, LEDs, and Rear Panel Features; PowerCage MTP 15HD RSA Board Connectors; MTP T 15HD RSA board —; Unbalanced Stereo Input; Do not tin the wires!; Captive Screw Connector Wiring for Stereo Audio Input; MTP R 15HD RSA SEQ board —
3. Carefully slide the board into the slot, aligning the two tabs on the lower front end of the board with the matching ports in the enclosure. Push the board firmly into place. Tighten the screws to secure the board in place. NOTE: Use a tool to fully tighten the screws after initial installation a...
Page 10 - Mono Audio Output; Captive Screw Connector Wiring for Audio and/or RS-232 Output; Typical Audio Connectors; This switch toggles pre-peaking; and on the type of cable, graphic card, and display used in the system.; See distance table on page 7
NOTE: The receiver auto-detects whether the signal on the audio/RS-232 pair of the TP input is audio or RS-232. It then converts the signal content accordingly, and outputs the signals on the appropriate pins of this connector. Receive (Rx) Transmit (Tx) Ground ( ) Bidirectional Mono Audio Output RS...
Page 11 - Maximum Transmitter to Receiver Distance — Analog Signals at 60 Hz; Video Format; Component Video; Maximum Transmission Distances for Analog Signals at 60 Hz; Connect to this for; Skew; This recessed button selects between,; Rotary Adjust Knob (MTP R 15HD RSA SEQ only) —; Within any function, rotate this
Maximum Transmitter to Receiver Distance — Analog Signals at 60 Hz Video Format With Pre-Peak Off. Feet (Meters) With Pre-Peak On. Feet (Meters) Max. Distance (High Quality). Feet (Meters) Max. Distance (Variable Quality). Feet (Meters) Composite, S-video, Component Video 800 (245) 1000 (300) 640 x ...
Page 12 - PowerCage Front Panel Port, Control, and Indicators; PowerCage Front Panel; The Comm function only works with fiber optic boards.; Temperature LED —
PowerCage Front Panel Port, Control, and Indicators The following features are on the front panel of the PowerCage enclosure. PowerCage 1600 COMM 1 POWER ALARM 2 3 14 15 16 1 PSU 2 PSU 1 FAN 2 FAN COMM SELECT CONFIG TEMP 3 4 5 6 2 1 Figure 7. PowerCage Front Panel a Comm LED (Slots 1-16) — This LED ...
Page 13 - Board Setup and Operation; On the MTP T 15HD RSA board; Changing the MTP T 15HD RSA Board Settings; Set the DIP switches as required.; Switch Position; Audio; Select the desired refresh rate.; Position
Board Setup and Operation On the MTP T 15HD RSA board there are two DIP switches (switch #1 is for refresh rate, switch #2 is for audio/RS-232), and a 16-position rotary encoder for EDID selection. The factory set defaults for these are: • DIP switch #1 is 60 Hz (down) • DIP switch #2 is audio (down...
Page 14 - up; Button; right
Changing the MTP T 15HD RSA Board Settings Change any of the four active DIP switches to the settings as shown in the table below. Switch Position Switch #1 Setting Switch #2 Setting Switch #3 Setting Switch #4 Setting Switch #5 Setting Switch #6 Setting Up/On H+ V+ Bidirectional S-Video green = lum...
Page 15 - left; For Level Adjustment.; four; For Peaking Adjustment.; five; Resetting Skew Delay, Level and Peaking; press and hold; Operation; contact numbers
2. Noting the color that is shifted furthest left , press the select button accordingly to select that color (see table above). The corresponding LED lights. 3. Viewing the image, slowly rotate the Adjust knob until the selected color converges with the color furthest right. 4. Repeat steps 2 and 3 ...
Page 16 - Specifications; Video — PowerCage MTP T 15HD RSA, PowerCage MTP R 15HD RSA SEQ
Reference Information This section provides the specifications and part numbers for the PowerCage MTP T 15HD RSA and MTP R 15HD RSA SEQ modular boards. • Specifications • Part Numbers Specifications Video — PowerCage MTP T 15HD RSA, PowerCage MTP R 15HD RSA SEQ Gain ....................................
Page 18 - General
General Recommended cable type .............. Extron Enhanced Skew-Free ™ A/V UTP, CAT 5/5e/6 (shielded or unshielded) Power consumption* ..................... 1 or 2* (positive-negative), 100 VAC to 240 VAC, 50-60 Hz; internal, hot-swappable * A redundant power supply is optional. Each MTP board at...
Page 19 - Part Numbers; PowerCage MTP 15HD RSA Part Numbers; Included Parts; Captive screw 5-pole connectors; Cables and Connectors; Enhanced Skew Free
Part Numbers PowerCage MTP 15HD RSA Part Numbers The PowerCage MTP 15HD RSA boards must be installed in a PowerCage 1600 enclosure. PowerCage Boards Part number PowerCage MTP T 15HD RSA 70-817-01 PowerCage MTP R 15HD RSA SEQ 70-818-01 Included Parts These items are included in each order for a Power...
Page 20 - and Central America:; Extron; USA; xtron; Warranty
Extron USA - West Headquarters + 800.633.9876 Inside USA/Canada Only +1.714.491.1500+1.714.491.1517 FAX Extron USA - East +800.633.9876 Inside USA/Canada Only +1.919.863.1794+1.919.863.1797 FAX Extron Europe +800.3987.6673 Inside Europe Only +31.33.453.4040+31.33.453.4050 FAX Extron Asia +800.7339.8...