Page 2 - Precautions; FCC Class A Notice; Extron’s Warranty
Precautions This symbol is intended to alert the user of importantoperating and maintenance (servicing) instructionsin the literature provided with the equipment. This symbol is intended to alert the user of thepresence of uninsulated dangerous voltage withinthe product's enclosure that may present ...
Page 4 - iii; Chapter 1 • Introduction; Chapter 3 • Maintenance and Modifications; Table of Contents
iii HSA 200/222 Series • Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About the Hideaway Surface Access Products ....... 1-2 About the Extender board line driver .................................. 1-4 Features ................................
Page 5 - iv; Table of Contents, cont’d; HSA 200/222 Series Surface Access Products; Chapter One; Introduction; About the Hideaway Surface Access Products; Appendix A • Reference Information
iv HSA 200/222 Series • Table of Contents Table of Contents, cont’d HSA 200/222 Series Surface Access Products 1 Chapter One Introduction About the Hideaway Surface Access Products Features 68-695-01 Rev. H 08 08 All trademarks mentioned in this manual are the properties of their respective owners. ...
Page 7 - About the Extender board line driver; Features; All models; Signal boosting ability
HSA 200/222 Series • Introduction HSA 200/222 Series • Introduction Introduction 1-4 The installed enclosures fit nearly flush within a table or podiumtop (figure 1-4), storing the connectors out of the way and out ofsight. To access the connectors, the user presses down on thetop of the enclosure, ...
Page 8 - Chapter Two; Installation
HSA 200/222 Series • Introduction Introduction HSA 200/222 Series Surface Access Products 2 Chapter Two Installation Installation Overview Preparing the Routing Template Preparing the Table and Mounting the Enclosure Underside Features and Cabling Connections Front Panel Connectors Pre-installation ...
Page 9 - Preparing the Routing Template; CAUTION; Installation Overview; For HSA 200SE and HSA 200CE model installations
HSA 200/222 Series • Installation HSA 200/222 Series • Installation Installation 2-3 Preparing the Routing Template Extron provides a metal template for each HSA model at nocharge . Appendix A lists the HSA 200 and HSA 222 template part numbers. Extron recommends using this template as aguide to cut...
Page 10 - Preparing the Table and Mounting the Enclosure; Preparing the table with a router
HSA 200/222 Series • Installation HSA 200/222 Series • Installation Installation, cont’d 2-5 2-4 Preparing the Table and Mounting the Enclosure The preferred and recommended method for preparing thetable is to use the appropriate Extron routing template and arouter. The templates are available at no...
Page 12 - Underside Features and Cabling Connections; All HSA 200 models only; AC power outlet —; HSA 200C and HSA 200S (no Extender board) only; Audio output connection —
HSA 200/222 Series • Installation HSA 200/222 Series • Installation Installation, cont’d 2-8 2-9 5 . Snugly tighten the Philips head screws on the screwclamps to secure the enclosure to the surface. CAUTION Overtightening the Philips head screws on the screwclamps can bend the clamp’s horizontal fla...
Page 13 - HSA 200CE and HSA 200SE (Extender board) only
HSA 200/222 Series • Installation HSA 200/222 Series • Installation Installation, cont’d All HSA 200 and HSA 222 models 4 Screw clamp bracket/screw clamp — These two brackets/ clamps hold the enclosure firmly in place in the mounting hole. 5 AC power input connection — Connect this cord to the power...
Page 14 - Front Panel Connectors
HSA 200/222 Series • Installation HSA 200/222 Series • Installation Installation, cont’d 2-12 Power connector wiring 1 . See figure 2-10. Plug the input connector of the included100-240 VAC, 50/60Hz, 12 VDC power supply into the ACpower outlet on the underside of the enclosure ( 1 on figure 2-5). R ...
Page 15 - Computer video input (HSA 200 models only)
HSA 200/222 Series • Installation HSA 200/222 Series • Installation Installation, cont’d 2-14 The Universal AC outlet is fully compatible withEuroplug, British, Indian, Danish, and Italian plugtypes. See the universal AC outlet guide on the ExtronWeb site, www.extron.com , for compatibility details ...
Page 16 - Chapter Three; Maintenance and Modifications; Removing and Replacing the Enclosure; If the image does not appear or there is no sound; If the image is not displayed correctly
HSA 200/222 Series • Installation Installation, cont’d HSA 200/222 Series Surface Access Products 3 Chapter Three Maintenance and Modifications Removing and Replacing the Enclosure Replacing the Bezels Replacing the Gas Lift Adjusting the Top Panel 2-16 Pre-installation Testing and Troubleshooting(H...
Page 17 - HSA 200/222 Series • Maintenance and Modifications; Replacing the Bezels
Maintenance and Modifications HSA 200/222 Series • Maintenance and Modifications HSA 200/222 Series • Maintenance and Modifications 3-2 The most probable corrective maintenance procedures for yourHSA 200 or HSA 222 are leveling the top surface and replacingthe gas lifts. Most of the maintenance proc...
Page 18 - Maintenance and Modifications, cont’d; — while you —
HSA 200/222 Series • Maintenance and Modifications HSA 200/222 Series • Maintenance and Modifications Maintenance and Modifications, cont’d 2 . (HSA 222 models only) Remove the four Philips head screws from the front access panel (figure 3-1). Retain thescrews. Lift the panel away from the enclosure...
Page 22 - Adjusting the Top Panel
HSA 200/222 Series • Maintenance and Modifications HSA 200/222 Series • Maintenance and Modifications Maintenance and Modifications, cont’d 3-12 Removepivot nut. Remove gas lift. Figure 3-9 — Replacing the gas lift, HSA 222 model 9 . Insert the piston end of the replacement gas lift throughthe hole ...
Page 23 - Appendix A; Reference Information
HSA 200/222 Series • Maintenance and Modifications Maintenance and Modifications, cont’d HSA 200/222 Series Surface Access Products A Appendix A Reference Information Specifications HSA Part Numbers Included Parts Routing Templates Replacement Parts Accessories Top Plate Dimensions 3-14
Page 24 - Specifications; ID bits are terminated on pins 4 and 11.
HSA 200/222 Series • Reference Information HSA 200/222 Series • Reference Information Reference Information A-3 A-2 Specifications Video — HSA 200SE, HSA 200CE Gain ................................. Selectable: unity (0.7 V), (0.75 V) 50%, (0.8 V)100% Bandwidth ..................... 300 MHz (-3 dB) ...
Page 25 - Reference Information, cont’d; General; , for compatibility details on all plug types
HSA 200/222 Series • Reference Information HSA 200/222 Series • Reference Information Reference Information, cont’d A-4 General The Universal AC outlet is fully compatible with Europlug,British, Indian, Danish, and Italian plug types. See theUniversal AC outlet guide on the Extron Web site, www.extr...
Page 26 - All nominal levels are at ±10%; HSA Part Numbers; Part number
HSA 200/222 Series • Reference Information HSA 200/222 Series • Reference Information Reference Information, cont’d HSA 200C/HSA 200CE — international circular modelsTop plate (outer rim) ................... 8.5" diameter circle (21.6 cm diameter) circle Surface cutout (inside rim) ......... 8.0...
Page 28 - HSA 200/222 Series • Reference Information; Appendix B; Packaging for Shipment; TEMPLATE IS; NOT
HSA 200/222 Series • Reference Information Reference Information, cont’d HSA 200/222 Series Surface Access Products B Appendix B Packaging for Shipment A-10 Figure A-2 — HSA 200C/HSA 200CE/HSA 222C cutout dimensions 6.000 0.0325" (15.24 0.083 cm) 6.5" (16.5 cm) 8.0" (20.3 cm) 8.5" (2...
Page 30 - HSA 200/222 Series • Packaging for Shipment; Packaging for Shipment, cont’d
HSA 200/222 Series • Packaging for Shipment Packaging for Shipment, cont’d B-4 6 . Place the remaining foam shell on the other side of theHSA (figure B-4). Firmly push the foam shells together asfar as they will go to completely suspend the HSA unit. Figure B-4 — HSA unit suspended in the foam 7 . P...