Page 2 - Safety Instructions
Safety Instructions Safety Instructions • English WARNING: This symbol, , when used on the product, is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. ATTENTION: This symbol, , when used on the prod...
Page 3 - FCC Class A Notice; only; Extron Safety and; ” on the Extron website.; Copyright; © 2015 Extron Electronics. All rights reserved.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equ...
Page 4 - Conventions Used in this Guide; Notifications; CE; File; Specifications Availability
Conventions Used in this Guide Notifications The following notifications are used in this guide: ATTENTION: • Risk of property damage. • Risque de dommages matériels. NOTE: A note draws attention to important information. TIP: A tip provides a suggestion to make working with the application easier. ...
Page 5 - Contents; Introduction; Loading Firmware to the DA with Firmware
v Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Contents Contents Introduction ............................................................ 1 About the DTP HD DA4/DA8 230/330 ................ 1Features ............................................................. 1Application Diagrams ......
Page 6 - Features; — The DTP HD DA; HDMI input loop‐through; — The DTP HD DA series features an active local HDMI output
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Introduction 1 Introduction This guide describes the function, installation, and operation of the DTP HD DA4 4K and DTP HD DA8 4K series of distribution amplifiers. Unless otherwise stated, the terms “distribution amplifier” or “DA” refer to a...
Page 8 - Application Diagrams
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Introduction 3 Application Diagrams The diagrams below show typical applications for the DTP HD DA4/DA8 230/330. 100-240V ~ --A MAX 50/60 Hz DTP HD DA4 330 LAN 3 4 1 2 OUTPUTS INPUT HDMI LOOP THRU REMOTE Tx Rx RS-232 G RESET DTP HDBT Tx Rx Tx ...
Page 9 - Mounting the Units; Tabletop Use; ), in accordance with the directions included with the kit. For rack
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Installation and Operation 4 Installation and Operation This section of the guide describes the following topics concerned with the installation, setup, and operation of the DTP HD DA4 and DTP HD DA8 series of distribution amplifiers. z Mounti...
Page 10 - UL Rack-Mounting Guidelines; Front Panel Features
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Installation and Operation 5 UL Rack-Mounting Guidelines The following Underwriters Laboratories (UL) requirements pertain to the installation of the unit into a rack. • Elevated operating ambient temperature — If installed in a closed or mult...
Page 11 - Rear Panel Features
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Installation and Operation 6 Rear Panel Features 50/60Hz 100-240V 1.0A DTP HD DA4 330 LAN 3 4 1 2 DTP HDBT OUTPUTS INPUT HDMI LOOP THRU REMOTE Tx Rx RS-232 G RESET DTP HDBT OUT SIG LINK Tx Rx Tx Rx G RS-232 IR Tx Rx Tx Rx G RS-232 IR OVER TP O...
Page 12 - Reset button and LED; Remote RS‐232 connector
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Installation and Operation 7 G DTP/HDBaseT outputs — Use STP cables to connect these 4 (DA4 models) or 8 (DA8 models) outputs (see illustration on page 6 ) to the inputs of a compatible receiver (see Twisted Pair Recommendations for DTP Commun...
Page 13 - Connecting the Input Source; on
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Installation and Operation 8 Connecting the Input Source Use an HDMI cable to connect the input source to the female HDMI socket on the rear panel (see D on page 6 ). Follow these instructions to secure the input and output HDMI connectors to ...
Page 14 - Twisted Pair Recommendations for DTP Communication; Twisted Pair Cable Configuration; Supported Cables; XTP DTP 24 Plug; Package of 10
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Installation and Operation 9 Twisted Pair Recommendations for DTP Communication Use the following pin configurations for shielded twisted pair cables. 5 Pin 1 23 678 4 Wire color White-green Green White-orange White-blue Orange White-brown Bro...
Page 15 - Wiring for RS-232 Control; Command and Response Table for; Wiring the DTP HD DA4 and DA8 Series for RS‐232 Control
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Installation and Operation 10 Wiring for RS-232 Control RS-232 communication between the distribution amplifier and a host PC can be used to update firmware or configure the unit using SIS commands (see Command and Response Table for SIS Comma...
Page 16 - SIS Commands; Introduction to SIS; Host-to-Distribution Amplifier Communications; © Copyright 20; is the year the currently installed firmware was released,; xxxx; is the catalog part number.
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • SIS Commands 11 SIS Commands This section provides information about the SIS commands that are used to configure the DTP HD DA4 and DTP HD DA8 series. The following topics are discussed: z Introduction to SIS z Symbols Used in this Guide z DTP...
Page 17 - Symbols Used in this Guide; ASCII to HEX Conversion Table; Symbol Definitions; See the; DTP HD DA4/DA8 EDID Memory
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • SIS Commands 12 Symbols Used in this Guide When programming in the field, certain characters are most conveniently represented by their hexadecimal rather than their ASCII values. The table below shows the hexadecimal equivalent of each ASCII ...
Page 19 - Error Messages; — Invalid output channel number (too large); EDID; User assigned mode; for consistency with the value in the SIS commands.
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • SIS Commands 14 Error Messages E01 — Invalid output channel number (too large) E10 — Invalid command E13 — Invalid value (too large) EDID User assigned mode In user assigned mode, the user can select from 55 factory loaded EDID files, each cat...
Page 20 - DTP HD DA4/DA8 EDID Memory Locations
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • SIS Commands 15 DTP HD DA4/DA8 EDID Memory Locations X$ Native Resolution Refr esh Rate Rate Type Video Format Audio Type File Name X$ Native Resolution Refr esh Rate Rate Type Video Format Audio Type File Name 1 800x600 60 Hz PC DVI n/a EXN_D...
Page 21 - Command and Response Table for SIS Commands
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • SIS Commands 16 Command and Response Table for SIS Commands Command ASCII Command(host to unit) Response(unit to host) Additional Description Video Mute Video mute single output X! * X6^ B/b Vmt X! * X6^] Video mute output X! only 1 , 2 , 3 , ...
Page 25 - Using the Internal Web Pages; Accessing the Internal Web Pages; To access the Internal Web Pages:
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Internal Web Pages 20 Reference Information This section provides information about updating the firmware of the DTP HD DA models. The following topics are discussed: z Using the Internal Web Pages z Updating the Device Firmware Using the Inte...
Page 26 - Setting Up the Device with the Internal Web Pages
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Internal Web Pages 21 Setting Up the Device with the Internal Web Pages Output status This section displays the status of all connected outputs. This section is not configurable. Input status This section displays the status of the connected i...
Page 27 - Updating the Device Firmware; Downloading Firmware; Firmware Link on the Download Tab; Installation Wizard; Downloading and Installing Firmware Loader; Download Center
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Internal Web Pages 22 Updating the Device Firmware Update the device firmware via either the Internal Web Pages or the Extron Firmware Loader software. Downloading Firmware To obtain the latest version of firmware for your distribution amplifi...
Page 28 - Download; Firmware Loader Download Link; Loading Firmware to the DA with Firmware Loader
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Internal Web Pages 23 3. On the next Download Center screen, locate Firmware Loader and click its Download link. 1 1 Figure 6. Firmware Loader Download Link 4. On the next screen, enter the requested information, then click the Download fw_loa...
Page 29 - DTP HD DA; Device Name; USB; Connect; Add; Firmware Loader
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Internal Web Pages 24 5. Select the DTP HD DA product from the Device Name menu. 6. Select RS-232 , USB , or TCP/IP from the Connection Method menu. 7. Depending on the connection method that selected, additional options appear. Make the appro...
Page 30 - Loading Firmware to the DA with Internal Web Pages; In the; Update; Browse; button and locate and select the desired firmware file, then click; Open; Click the; Upload
Extron DTP HD DA4 4K 230/330 and DTP HD DA8 4K 230/330 • Internal Web Pages 25 Loading Firmware to the DA with Internal Web Pages 1. Using an internet browser, navigate to the device Internal Web Pages. 2. In the Device Info section, click the Update button. 3. Click the Browse button and locate and...
Page 31 - Extron Warranty
Extron Headquarters +1.800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX Extron Europe +800.3987.6673 (Inside Europe Only)+31.33.453.4040 +31.33.453.4050 FAX Extron Asia +65.6383.4400+65.6383.4664 FAX Extr...