Page 2 - System; unPackIng and InSPectIon; WARNING; Processor assembly mounting; figure 7
20.0 508 5.0 127 3.1 80 16X .33 THRU 8.4 17.8 45216.6 42215.4 39114.2 361 4.2 107 Low TDS Outlet (Steamer) Inlet (From Filter System) Reduced TDS Outlet (Coffee) ENVI-RO System 2SR-BW Conditioning Car tridge MR-6 0 0 RO Car tridge RO Reject (3/8" John Guest) route to drain figure 1. Wall mount b...
Page 3 - figure 1; Piping/ tubing connections; figure 2; Reject to Drain, Maximum”; Inlet
figure 4. Reject Y-Connector Detail figure 3. Inlet and Outlet Connections 3 Refer to 3. figure 1 for mounting bracket details. Position the top row of holes 1-9/16" inches below the top of the processor when installed. Install the wall mount bracket to a suitable ver tical surface. Use no less ...
Page 4 - control SyStem oPeratIon; operational mode; Press and hold any key for 3 seconds to enter set-up mode.; electrical connections
4 ENVIRO V. X.XX TOTAL: XXXX.XX Hours control SyStem oPeratIon The ENVI-RO system includes a micro-processor based control system that monitors system conditions and controls the system operation. A digital display panel provides operational information and 4 but tons provide operator access. To fol...
Page 5 - cartrIdge InStallatIon and actIVatIon; do not uSe tHIS Product Water! It may contain; recoVery adjuStment; Capillary
5 cartrIdge InStallatIon and actIVatIon Remove the outer shrink-wrap and protective cap from the 1. 2SR-BW & MR-600 RO car tridges. Position a bucket under the 2SR -BW car tridge head. Slowly open the Inlet shut-off valve. Apply power to the system by plugging the power cord into the receptacle....
Page 7 - figure 6
7 dISInfectIon When car tridge activation and recovery adjustments are complete, the storage tank and associated piping must be disinfected, then completely flushed. The steps for this are outlined below. Locate the 3/8" OD tubing that connects to the inlet (lef t side) 1. of the storage tank. D...
Page 8 - ro Production; †Production rates based on the following:; Stored Water System; *Specifications Subject To Change Without Notice.
8 Performance* SectIon ro Production † enVI-ro 600 Gallons per Day 600 Gallons per Hour 25 Ounces per Minute 53 Inlet Supply Requirements, Minimum 1.5 gpm Reject to Drain, Maximum 0.85 gpm †Production rates based on the following: 750 ppm TDS Sof t Water @ 50 psi, 77°F, to Atmosphere, Recovery = 4 0...
Page 10 - troubleSHootIng guIde; Problem
10 troubleSHootIng guIde Problem Possible cause remedy Insuf ficient product water 1. during normal operating periods. a. Pre-filtration system restriction. Check pre-filtration system and/or replace pre- a. filter car tridge(s). SR car tridge plugged. b. Replace SR car tridge. b. RO car tridge plug...
Page 11 - rePlacement PartS
key Part no. deScrIPtIon 1 E V311192 Valve, Ball, 3/8” PI x 3/8” PI 2 E V312810 Pressure Reducing Valve 3 E V312839 Valve, Control (FBV) 4 E V312808 Valve, Solenoid 5 E V312818 Pump 6 E V312809 Accumulator Tank without Bladder 7 E V312814 Bladder 8 E V312817 Controller 9 E V312815 Power Supply 10 E ...
Page 12 - maIntenance; – replace the ro cartridge:
12 maIntenance The ENVI-RO requires very lit tle maintenance. Regular car tridge replacement is the only normal requirement, and a very impor tant one. In t ypical service, the car tridge change-out schedules are as listed below. every 6 months - replace the Sr cartridge: Open both by-pass valves. •...
Page 13 - Dimensional Drawing
13 13.6" 346 23" 583 406 16" 32" Side View Front View Top View 813 figure 7. Dimensional Drawing
Page 14 - General Installation Arrangement
Page 16 - technical Service
technical Service 800.942.1153 www.everpure.com Printed in U.S.A. EV3128-25 Rev A - SE08 for sales, replacement components, and service, contact your everpure dealer or: everpure, llc: 1040 Muirfield Drive • Hanover Park, Illinois 60133 • 800.323.7873