Page 2 - SPIRAL ICEMAKER-DISPENSER; Operator’s Manual
SPIRAL ICEMAKER-DISPENSER MODEL: SID650A/80 SID650W/80 SID650A/80--BC SID650W/80--BC Operator’s Manual PRINTED IN U.S.A â REMCOR INC: 1995 Part No. 90846 August 1997 Revision FTHIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before installing or operating this equ...
Page 3 - TABLE OF CONTENTS
i 90846 TABLE OF CONTENTS Page SAFETY PRECAUTIONS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DESCRIPTION 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UNPACKING 2 ...
Page 5 - SAFETY PRECAUTIONS
1 90846 SAFETY PRECAUTIONS Always disconnect power to the dispenser before servicing or cleaning. Never place hands inside of hopper or gate area without disconnecting power to the dispenser. Agitator rotation occurs automatically when the dispenser is energized! This ice dispenser has been specific...
Page 6 - DESCRIPTION; UNPACKING
2 90846 DESCRIPTION The REMCOR LOW PROFILE S.I.D. (Spiral Ice â Icemaker Dispenser) is a unique, self-contained, free stand- ing style unit which automatically makes hard, clear cube-quality ice and stores it in a sealed hopper for sanitary dispensing. The ice is made by a new, patented process on a...
Page 7 - INSTALLATION; LOCATION; PLUMBING; ELECTRICAL
3 90846 INSTALLATION WARNING: Only qualified personnel should service internal components or electrical wiring. LOCATION Locate the icemaker/dispenser indoors in a well ventilated area. Avoid exposure to direct sunlight and/or heat caused by radiation. Ambient room temperature must be in the range o...
Page 8 - BEVERAGE SYSTEM; Installation
4 90846 BLACK (HOT) WHITE (NEUTRAL) GREEN (GROUND) SUPPLY CONDUIT 115V 60 HZ, 1PHASE FIGURE 1. REAR VIEW - BOTTOM SECTION SERVICE PANEL REMOVED BEVERAGE SYSTEM “B”, Models: contain beverage faucets only and must be supplied with cold product from any remote cold plate or refrigerated soda factory. “...
Page 13 - START UP; ICEMAKER
9 90846 START UP ICEMAKER 1. Open the hinged service door on the upper left side panel. Remove ice drop cover and storage hopper cov- er. 2. Turn on water to icemaker. Make sure that the proper water level is attained in the float chamber before starting unit. 3. Depress the flush switch for 30 seco...
Page 14 - OPERATING INSTRUCTIONS; ICEMAKER OPERATING INSTRUCTIONS
90846 10 OPERATING INSTRUCTIONS ICEMAKER OPERATING INSTRUCTIONS A temperature sensing bulb located in the storage hopper starts and stops the icemaking process (compressor) in response to the ice level in the hopper. With this ice level control “calling”for ice (hopper ice level is low), the total c...
Page 17 - REFRIGERATION SCHEMATIC
90846 13 REFRIGERATION SCHEMATIC COMPARTMENTFAN B A WATER- -COOLED MODELS AIR- -COOLED MODELS TXVPRESSURETAP TXVBULB LOW PRESSURECONTROL EVAPORATOR B A EXPANSIONVALVE (TXV) SUCTIONACCUMULATOR SIGHTGLASS LOW SIDESERVICEPORT COMPRESSOR HIGH SIDESERVICEPORT HIGHPRESSURECONTROL HOT GASSOLENOIDVALVE COND...
Page 18 - MAINTENANCE; CLEANING INSTRUCTIONS; Ice Maker Section
90846 14 MAINTENANCE It is recommended that the air inlet filter be cleaned ever 3 months or sooner, depending on the operating envi- ronment for proper refrigeration system performance. On air-cooled units. also check that the condenser is free of dirt/foreign material that could cause air flow blo...
Page 19 - Dispenser Section; FOR UNITS WITH BEVERAGE SYSTEM; Cold Plate
90846 15 8. Open the water supply valve and fill evaporator with water (level is up in float reservoir). 9. Put the clean/run switch in the “clean”position. Allow unit to run in the cleaning mode for at least 30 min- utes. 10. Put the clean/run switch in the “run”position. 11. Close the water supply...
Page 20 - Beverage System
90846 16 2. Remove cold plate cover by loosening thumbscrew on the ice drop chute and lowering chute from plastic drop tube. then, remove cover by lifting slightly in front and slide forward. 3. Wash down the inside of the cold plate, tray and cover with mild detergent solution and rinse. A small, l...
Page 21 - MAINTENANCE/ADJUSTMENT PROCEDURE; THERMOSTAT ALTITUDE ADJUSTMENTS; Bin Thermostat; CLEARING EVAPORATOR FREEZE-UP; ICE THICKNESS ADJUSTMENT
90846 17 MAINTENANCE/ADJUSTMENT PROCEDURE THERMOSTAT ALTITUDE ADJUSTMENTS IMPORTANT: Adjust the bin thermostat setting only if storage hopper over fill is a problem. Bin Thermostat 1. Open the hinged service door on the upper left side panel. 2. The adjustment screw is located below the “Flush”switc...
Page 22 - CLEANING / REPLACING THE FILTER; HARVEST TIMER ADJUSTMENT
90846 18 2. Collect and weigh the ice produced during the harvest cycle. The amount of ice harvested should be 3 ¼ to 3 ½ pounds. Use the following procedure to adjust the probe to obtain this weight. (A clockwise adjustment will reduce the harvest weight, while counter clockwise turns will increase...
Page 23 - MANUAL FILLING
90846 19 A. “Manually”adjust the cam tabs by using each “click”as the cam tab is rotated as equivalent to .75 se- conds. B. Set up cam wheel #1 with the left and right cam tabs back-to-ack as shown in figure NO TAG. C. Adjust the cam tabs on wheels #2 through #5 in sequence as shown in the chart. Ro...
Page 25 - TROUBLESHOOTING GUIDE
21 90846 TROUBLESHOOTING GUIDE The following pages contain troubleshooting charts designed to aid and experienced service person in diagnos- ing any operating problems which may be experienced. It is assumed that normal service techniques and skill are familiarly to the person doing the trouble shoo...
Page 38 - PARTS LIST
34 90846 PARTS LIST Item No. Description PART NO. Air Cooled Water Cooled Dispenser Components 80 80 “BC” 80 80 “BC” 1 Gate Slide 21491 21491 21491 21491 2 Depressor Retainer 22644 22644 22644 22644 3 Agitator 22855 21854 22855 21854 4 Vend Switch 30895 30895 30895 30895 5 Switch Boot 31007 31007 31...
Page 40 - WARRANTY; IMI Cornelius Offices
36 Manual number IMI CORNELIUS INC . O NE C ORNELIUS P LACE A NOKA, MN . 55303--6234 T ELEPHONE (800) 238--3600 F ACSIMILE (612) 422--3232 T ECH S VC 1-800-535-4240 WARRANTY IMI Cornelius Inc. and Remcor Products Company warrants that all equipment and parts are free from defects in material and wor...