Page 2 - Table Of Contents
Table Of Contents WARRANTY INFORAMTION 1 TROUBLESHOOTING 2-6 INSTALLATION 2 W ASH CYCLE 2-5 DRY CYCLE 5-6 SPARE PARTS CATALOG 7-18 CABINET 7-9 OSCILLATING GROUP 10-12 CONTROLS 13-14 W ATER INLET 15-16 VENTILATION 17-18 TESTING THE ELECTRONIC CONTROL MODULE 19 TESTING THE DRIVE MOTOR 20 CIRCUIT DIAGR...
Page 3 - WARRANTY INFORMATION
WARRANTY INFORMATION Your Equator appliance is protected by this warranty under normal,personal, family or household use (1 Year), and limited commercial use(90 days) in the USA and Canada. WARRANTY EXCLUSIONS ... Equator Corporation undertakes to the consumer-ownerto repair or, at Equator Corporati...
Page 4 - Troubleshooting; Installation
Troubleshooting 2 Problem Possible Cause Repair procedure 1. Machine vibratingor vibrating noise 1a. Shipping brackets notremoved 1a. Open back of machine, remove 4 shippingbrackets connecting cabinet to drum 1b. Machine not leveled 1b. Adjust front leveling legs and tightenlocknuts 1c. Machine inst...
Page 7 - Dry Cycle
Problem Possible Cause Repair Procedure 11. Machineoverfills. 11a. Pressure Switch. 11a.Unplug unit. With excessive water still intub, check for continuity between terminals 21and 22. Drain machine, then replace pressureswitch if test indicates continuity. 11b. Pressur Switch Hose. 11b. Drain machin...
Page 9 - TABLE 1
9 Pos. Part Number Part Name Pos. Part Number Part Name 1 111100830 Top panel 25 119803003 Levelling leg 1 111100926 Top panel 2500 C 26 116102761 Electronic door switch 2 112903512 Top decorative trim 28 182990046 Hook stop plate 3 116103031 Electronic module assy. 29 113200491 Clamp 4 116990422 Ju...
Page 13 - TABLE 2
12 Pos. Part Number Part Name Pos. Part Number Part Name 1 114200661 Porthole Diaphragm 28 114900269 Upper counterweight 2500 C 1 114200670 Porthole diaphragm for 2500 C 28 114900273 Upper counterweight 2 113200012 Clamp 29 113800458 Conic spring 4 119200763 Tub assy. Stainless steel 1500 30 9931000...
Page 14 - TABLE 3
Page 16 - TABLE 4
Page 18 - TABLE 5
Page 21 - Testing the Electronic Control Module
To help avoid electrical shock, no live electrical test of the Electronic Control Modulewill be made. Start by unplugging the unit, then remove theconnector from terminals 10 and 11 of theElectronic Control Module. W ith this connectorremoved, plug the unit in, set the dry timer to10 minutes, then p...
Page 22 - Testing the Drive Motor
20 Testing the Drive Motor (7 and 10 pin connector)
Page 24 - TIMER CHART
Page 25 - E Q U A T O R S E R V I C E A G R E E M E N T; EQUATOR’S RESPONSIBILITIES:
E Q U A T O R S E R V I C E A G R E E M E N T Dear Service Agent: Welcome to the world of Equator! We are pleased to appoint you as an Equator Authorized Service Agent . Equator is an appliance manufacturer that produces Advanced Appliances. Our products are unique, innovative appliances that are hi...