Page 2 - ENFORCER Delayed Egress Timer
ENFORCER Delayed Egress Timer 2 SECO-LARM U.S.A., Inc. Remote Alarm Relay Output ......................... 8 Lock Relay Output ........................................ 8 Local Alarm Output ....................................... 8 Pre-Delay Bypass Input ................................ 8 Free Egress...
Page 3 - SECO-LARM U.S.A., Inc 3
ENFORCER Delayed Egress Timer SECO-LARM U.S.A., Inc 3 SECO-LARM U.S.A., Inc. 33 3 Dimensions: Overview: Housing Timer module only *Normally energized. Relock mode jumpers (see pg. 5) Jumpers (see pg. 7) DIP Switch for Power-up mode & Nuisance delay (see pg. 6) Pre-delay timer potentiometer (see ...
Page 4 - Remote alarm relay output
ENFORCER Delayed Egress Timer 4 SECO-LARM U.S.A., Inc. Wiring Diagram: Installation: Removing the housing To remove the housing cover from the SA-025EQ, use a paper clip or a similar object to push one of the two tabs on the back of the unit inward. Push tab inward. Mounting If mounting is necessary...
Page 5 - SECO-LARM U.S.A., Inc 5; IMPORTANT; standard mode; Wiring Diagram
ENFORCER Delayed Egress Timer SECO-LARM U.S.A., Inc 5 SECO-LARM U.S.A., Inc. 33 5 IMPORTANT Users and installers of this product are responsible for ensuring that the installation and configuration of this product complies with all national, state, and local laws and codes related to locking and egr...
Page 6 - Setting the Power-Up Mode and Nuisance Delay:; Relock Modes
ENFORCER Delayed Egress Timer 6 SECO-LARM U.S.A., Inc. Adjusting the Pre-Delay and Post-Delay: Pre-delay timer potentiometer Post-delay timer potentiometer The pre-delay and post-delay timers can be adjusted using the potentiometers located on the bottom left of the circuit board. Pre-Delay: The pre...
Page 7 - SECO-LARM U.S.A., Inc 7; Local Alarm Output Type Jumper:
ENFORCER Delayed Egress Timer SECO-LARM U.S.A., Inc 7 SECO-LARM U.S.A., Inc. 33 7 Lock Status Jumper: When the lock status jumper is ON, the lock status input will detect whether the door is closed and will trigger relock functions. The lock status input may be bypassed in order to keep the door...
Page 8 - Remote Alarm Relay Output:; seconds (door status jumper must be ON for this to occur).
ENFORCER Delayed Egress Timer 8 SECO-LARM U.S.A., Inc. Remote Alarm Relay Output: The SA-025EQ is equipped with a 10A@24VDC Form C dry relay output for a remote alarm. The remote alarm relay is normally energized. The onboard screen print refers to the energized state as normal. A remote alarm...
Page 9 - SECO-LARM U.S.A., Inc 9
ENFORCER Delayed Egress Timer SECO-LARM U.S.A., Inc 9 SECO-LARM U.S.A., Inc. 33 9 Reset Input (N.C.+): Connect a N.C. switch between the reset input and the positive terminal. The reset input is used to reset the SA-025EQ. The reset input is only necessary in the standard relock mode. Initiate...
Page 10 - Sample Application – Installation in a Building; Relock mode set to standard mode.; An electromagnetic lock is connected to the lock relay output.
ENFORCER Delayed Egress Timer 10 SECO-LARM U.S.A., Inc. Sample Application – Installation in a Building In this application, the SA-025EQ is used to delay exit from a building. Relock mode set to standard mode. Pre-delay timer set to 15 seconds. Power-up mode set to automatic relock (DIP Swi...
Page 11 - SECO-LARM U.S.A., Inc 11; Sample Application – Installation with a Gate Operator
ENFORCER Delayed Egress Timer SECO-LARM U.S.A., Inc 11 SECO-LARM U.S.A., Inc. 33 11 Sample Application – Installation with a Gate Operator In this application, the SA-025EQ is used to warn that a gate is about to open or close. This application is only for gates that use the same input for both ...
Page 12 - Adjusting the Pre-Delay and
ENFORCER Delayed Egress Timer 12 SECO-LARM U.S.A., Inc. NOTICE The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change spec...