Page 2 - Contents
Copyright © Emerson Process Management, 2014. All rights reserved. Printed in the USA. Trademarks The Emerson logo is a trademark and service mark of Emerson Electric Co. AMS is a mark of one of the Emerson group of companies. FOUNDATION ™ is a mark of the Fieldbus Foundation of Austin, Texas, USA. ...
Page 3 - Introduction
1 Introduction This manual guides you in using the USB Fieldbus Interface (interface) topower and/or configure fieldbus devices. Included here are basic setup,configuration, and troubleshooting information, as well as guidelines on howto use the interface with AMS Suite: Intelligent Device Manager a...
Page 4 - Safety message
1.1 Safety message WARNING! Do not connect the USB Fieldbus Interface to a live segment (with an active DCS Host and power supply attached) if the power indicator light on the interface is amber in color. Doing so can disrupt communications and may compromise automation safety. User's Manual May 201...
Page 5 - USB Fieldbus Interface; Topics covered in this chapter:; Overview; It is particularly useful in these plant scenarios:
2 USB Fieldbus Interface Topics covered in this chapter: • Overview • Parts and function • Power modes 2.1 Overview The USB Fieldbus Interface enables two-way communication between acomputer and fieldbus devices. Its primary function is to allow the setup,configuration, monitoring, and troubleshooti...
Page 6 - Box contents
The USB Fieldbus Interface comes with a USB cable, lead set, user's manual*,and installation CD*. Box contents Figure 2-1: User's Manual May 2014 6
Page 7 - Parts and function
2.2 Parts and function USB Fieldbus Interface Figure 2-2: 1 Field connection indicator light (*) Indicates the fieldbus device connection status 2 Power indicator light (*) Indicates the power mode of the interface 3 USB port Enables USB connection 4 Fieldbus device connection socket Enables fieldbu...
Page 8 - Indicator light scenarios
Indicator light scenarios Table 2-1: Power indicator light Field connection indicator light Scenarios Normal scenarios Green Green The USB Fieldbus Interface is connected to an externally powered segment and is able to communicate. Amber Green The USB Fieldbus Interface is providing power to a field...
Page 9 - Power modes; - The interface does not supply power to the connected fieldbus
2.3 Power modes The USB Fieldbus Interface is capable of working in two power modes: • Mode 1 - The interface does not supply power to the connected fieldbus device or segment. The fieldbus device or segment is powered by anexternal source. Mode 1 is the default. • Mode 2 - The interface powers the ...
Page 10 - Software installation and device setup; This enables DTM support for connected fieldbus devices.; Install the Emerson DTM Library.; System requirements
3 Software installation and device setup Topics covered in this chapter: • System requirements • Install the Fieldbus Interface Configuration utility • Install the Communication DTM software • Install the Emerson DTM Library • Setup and connection • Connect to a live fieldbus segment Perform softwar...
Page 11 - Install the Fieldbus Interface Configuration utility; Notes; Appendix D; Fieldbus Interface Configuration utility installation; Finish
3.2 Install the Fieldbus Interface Configuration utility Notes • Do not connect the USB Fieldbus Interface to the computer or to a fieldbus device or segment until software installation is complete. • You may be prompted to determine the operating system and the Windows version (32-bit or 64-bit) ru...
Page 12 - Install the Communication DTM software; click; Communication DTM installation; Install the Emerson DTM Library; Navigate to the Emerson DTM Library folder.
3.3 Install the Communication DTM software 1. Insert the USB Fieldbus Interface installation CD into the CD drive of your computer. 2. Navigate to the Emerson USB Fieldbus Interface DTM folder and double- click Setup.exe . 3. Click Next and follow the prompts on the installation window. Communicatio...
Page 13 - Emerson DTM Library installation; Close
Emerson DTM Library installation Figure 3-3: 5. Click Close when done. May 2014 User's Manual 13
Page 14 - Setup and connection; Note; Power the connected fieldbus device or segment.
3.5 Setup and connection Note Install the Fieldbus Interface Configuration utility first before setting up and connecting the USB Fieldbus Interface. For more information, see Section 3.2 1. Connect the USB Fieldbus Interface to the computer using the USB cable provided. Driver installation should s...
Page 15 - Sample benchtop connection; Connect to a live fieldbus segment; that all software and drivers are installed.
Sample benchtop connection Figure 3-4: 3.6 Connect to a live fieldbus segment WARNING! Do not use the Provide Power option on the Fieldbus Interface Configuration utility when connecting to a live segment. Doing so can disrupt communications and may compromise automation safety. 1. Make sure the USB...
Page 16 - Fieldbus Interface Configuration utility; Launch the Fieldbus Interface Configuration utility; Click; No device detected dialog
4 Fieldbus Interface Configuration utility Topics covered in this chapter: • Launch the Fieldbus Interface Configuration utility • Power fieldbus devices • Commission fieldbus devices • Decommission fieldbus devices • Change the device class • Start or stop the USB FF HSE Server manually 4.1 Launch ...
Page 17 - Power fieldbus devices; Provide Power option
4.2 Power fieldbus devices You can power a fieldbus device or segment by connecting it to an externalpower source or by using the Fieldbus Interface Configuration utility. The following steps detail how to use the Fieldbus Interface Configurationutility to power fieldbus devices. 1. Launch the Field...
Page 18 - Commission fieldbus devices; the first available address is assigned.; Commission
4.3 Commission fieldbus devices Commissioning sets the fieldbus device address to a valid permanent addressand sets the device tag to a valid string. Notes • You need to commission fieldbus devices first before you can use them with AMS Device Manager or with an FDT Frame Application. • Fieldbus dev...
Page 19 - Repeat steps 2 through 5 for each device you want to commission.; Decommission fieldbus devices; Decommission
Commission Figure 4-3: Note The commissioning process takes about 1 to 2 minutes to complete. 6. Repeat steps 2 through 5 for each device you want to commission. 4.4 Decommission fieldbus devices Decommissioning sets the fieldbus device address to a temporary address. Note Fieldbus devices on a live...
Page 20 - Yes; Change the device class; Read
Decommission Figure 4-4: 4. Determine if the fieldbus device was commissioned on another host, then select Yes or No . • If you choose Yes , the decommissioning proceeds. • If you choose No , you cannot decommission the device. Decommissioning is not allowed for devices commissioned onanother host. ...
Page 21 - Identify the device class; Basic
Note Only the device class of a commissioned fieldbus device can be identified. For more information on commissioning a device, see Section 4.3 . Identify the device class Figure 4-5: 4. Switch to Basic or Link Master from the drop-down menu and click Apply . May 2014 User's Manual 21
Page 22 - Start or stop the USB FF HSE Server manually; not
Change the device class Figure 4-6: 5. Click Yes to acknowledge the restart of the device. 6. Click OK to continue. Note Changing the device class takes about 1 minute to complete. 4.6 Start or stop the USB FF HSE Server manually The USB FF HSE Server automatically starts when you launch the Fieldbu...
Page 24 - Using with AMS Device Manager; Add a network component in AMS Device Manager; Start
5 Using with AMS Device Manager Topics covered in this chapter: • Add a network component in AMS Device Manager • Configure fieldbus devices in AMS Device Manager AMS Device Manager provides a single application for predictive diagnostics,documentation, calibration management, and device configurati...
Page 25 - Add a network component; Select the FF HSE Network component, and click
Add a network component Figure 5-1: 3. Select the FF HSE Network component, and click Install . May 2014 User's Manual 25
Page 26 - Install an FF HSE network component; Next
Install an FF HSE network component Figure 5-2: 4. Click Next to proceed. 5. Enter a name for the FF HSE network, and click Next . User's Manual May 2014 26
Page 27 - Enter a network name; configure IP addresses for FF HSE linking devices.
Enter a network name Figure 5-3: 6. Choose to automatically discover FF HSE linking devices or manually configure IP addresses for FF HSE linking devices. May 2014 User's Manual 27
Page 29 - Configure fieldbus devices in AMS Device Manager; to open; USB Fieldbus Interface icon in AMS Device Manager; If you are using the Device Connection View, click the
7. Click Finish when done. 5.2 Configure fieldbus devices in AMS Device Manager Note Commission fieldbus devices first in the Fieldbus Interface Configuration utility before configuring them in AMS Device Manager. For more information, see Section 4.3 . 1. Click Start > All Programs > AMS Devi...
Page 30 - Displays the current output from the device.
Scanning synchronizes the AMS Device Manager database withconnected live devices. 6. Right-click the fieldbus device you want to configure and select from the context menus. Fieldbus device context menus Figure 5-6: Configure Displays configuration parameters that definethe physical attributes and o...
Page 31 - AMS Device Manager Books Online
For more information about the context menus and other AMS DeviceManager functions, refer to AMS Device Manager Books Online . May 2014 User's Manual 31
Page 32 - Using with an FDT Frame Application; Install an FDT Frame Application; For the purpose of this document, PACTware is used.; Update the DTM library; to show the Device catalog and click
6 Using with an FDT Frame Application Topics covered in this chapter: • Install an FDT Frame Application • Update the DTM library • Configure fieldbus devices in an FDT Frame Application You can also configure fieldbus devices using third-party FDT FrameApplications. For the purpose of this document...
Page 33 - Update device catalog; Configure fieldbus devices in an FDT Frame Application; HOST PC
Update device catalog Figure 6-1: 3. Click Yes when prompted to create a new PACTware device catalog. 4. Close the device catalog when done. 6.3 Configure fieldbus devices in an FDT Frame Application Notes • Install the Communication DTM software and the DTM Library first before configuring fieldbus...
Page 34 - Project pane; Press; Add the Emerson FF HSE Server; FF HSE Server
Project pane Figure 6-2: Press F2 to display the Project pane if it is not already displayed. 3. Select Emerson FF HSE Server and click OK . Add the Emerson FF HSE Server Figure 6-3: 4. Right-click FF HSE Server on the Project pane and click Add device . User's Manual May 2014 34
Page 35 - FF HSE Server - Add device; Emerson USB Fieldbus Interface
FF HSE Server - Add device Figure 6-4: 5. Select Emerson USB Fieldbus Interface and click OK . May 2014 User's Manual 35
Page 36 - Add the Emerson USB Fieldbus Interface
Add the Emerson USB Fieldbus Interface Figure 6-5: 6. Right-click USB Fieldbus Interface on the Project pane and click Add device . User's Manual May 2014 36
Page 37 - USB Fieldbus Interface - Add device; Select the device you want to add then click
USB Fieldbus Interface - Add device Figure 6-6: 7. Select the device you want to add then click OK . May 2014 User's Manual 37
Page 38 - Add device; Repeat steps 6 and 7 if you want to add more devices to the list.
Add device Figure 6-7: Only devices with DTMs available and installed appear on the list. Formore information on DTM library installation, see Section 3.4 . Repeat steps 6 and 7 if you want to add more devices to the list. 8. Right-click USB Fieldbus Interface and select Additional functions > Ed...
Page 39 - Edit DTM Address; device address in the Node ID field, and click; Enter Node ID
Edit DTM Address Figure 6-8: 9. On the right pane, select the fieldbus device from the list, enter the device address in the Node ID field, and click Apply . Enter Node ID Figure 6-9: May 2014 User's Manual 39
Page 40 - Connect devices; Connect
Note The device address and Node ID should match. The device address is set and can be found in the Fieldbus Interface Configuration utility. For more information on setting the device address, see Section 4.3 . 10. Right-click HOST PC and click Connect . Connect devices Figure 6-10: This connects a...
Page 41 - Parameter; This displays the various parameters you can edit for the device.
Parameter Figure 6-11: This displays the various parameters you can edit for the device. 12. Configure the parameters of the device. Note The parameter display varies and is dependent on the device manufacturer. May 2014 User's Manual 41
Page 42 - Edit device parameters
Edit device parameters Figure 6-12: User's Manual May 2014 42
Page 43 - Troubleshooting; Fieldbus device not responding in AMS Device Manager; Uncommissioned device in AMS Device Manager
7 Troubleshooting Topics covered in this chapter: • Fieldbus device not responding in AMS Device Manager • Fieldbus device not detected in Fieldbus Interface Configuration utility • Cannot edit device parameters in FDT Frame Application 7.1 Fieldbus device not responding in AMS Device Manager In ord...
Page 44 - Commissioned device in AMS Device Manager; Fieldbus device not detected in Fieldbus Interface
Commissioned fieldbus devices appear with their own icons in AMS DeviceManager and are characterized by a valid permanent address or by a validdevice string. Commissioned device in AMS Device Manager Figure 7-2: 7.2 Fieldbus device not detected in Fieldbus Interface Configuration utility The Fieldbu...
Page 46 - Cannot edit device parameters in FDT Frame Application; Cannot edit device parameters in PACTware; Commission the fieldbus device. For more information, see
7.3 Cannot edit device parameters in FDT Frame Application Cannot edit device parameters in PACTware Figure 7-4: • Check the Node ID in PACTware and the Device Address in the FieldbusInterface Configuration utility. The Node ID and Device Address shouldmatch. You may need to manually enter the Node ...
Page 47 - Appendix A; Approvals and certifications; Fieldbus Foundation Communication; FF Physical Layer Conformance Test (FF830); CE
Appendix A Approvals and certifications Fieldbus Foundation Communication FF Physical Layer Specification (IEC 61158-2) FF Physical Layer Conformance Test (FF830) CE EN 61326-1-2006, Radiated Emissions Class B, Basic Immunity TestRequirements. ETL (US and Canada) Conforms to ANSI/UL STD 60950-1; Cer...
Page 48 - Appendix B; Specifications
Appendix B Specifications Software Supported operating systems Windows 8.0 and 8.1Windows 7 (32- or 64-bit)Windows XP Home or Professional (32-bit) SP3 USB 1.1 and USB 2.0 interface Drivers included Application software AMS Device Manager Version 11.5 or later License AMS Device Manager HSE license ...
Page 49 - Appendix C; Waste disposal
Appendix C Waste disposal Products with the following label comply with the Waste Electrical andElectronic Equipment (WEEE) directive, 2002/96/EC, which applies toEuropean Union (EU) member states only. The label indicates this product should be recycled and not treated ashousehold waste. Customers ...
Page 50 - Install drivers manually; From the Found New Hardware Wizard, select the
Appendix D Install drivers manually Notes • If you have previously installed a pre-release version of drivers, follow the procedure in Appendix F first before installing new drivers manually. • The following procedure only applies to Windows XP operating systems. On Windows 7 operating systems, driv...
Page 51 - Found New Hardware Wizard - Select driver location
Found New Hardware Wizard - Select driver location Figure D-1: 5. Browse to where the drivers are located and click Next . The drivers are typically in C:\Program Files\Emerson Process Management\USB Fieldbus Interface\Drivers . 6. If a Windows Logo compatibility warning is displayed, click Continue...
Page 52 - Found New Hardware Wizard - Select best driver match
Found New Hardware Wizard - Select best driver match Figure D-2: If you want to verify the proper installation of drivers, open Windows DeviceManager and check that drivers are installed under Ports (COM & LPT) andUniversal Serial Bus controllers sections. User's Manual May 2014 52
Page 53 - Windows Device Manager
Windows Device Manager Figure D-3: May 2014 User's Manual 53
Page 54 - Appendix E; On the right panel, locate Advanced startup and select
Appendix E Disable driver signature enforcement in Windows8.0 and 8.1 1. Open the Windows 8 Charms bar.2. Click Settings > Change PC settings . 3. From the PC Settings window, select General on the left panel. 4. On the right panel, locate Advanced startup and select Restart now . 5. From the Cho...
Page 56 - Advanced Settings for COMxx dialog
Advanced Settings for COMxx dialog Figure F-1: 10. Click OK to close the Properties dialog. User's Manual May 2014 56
Page 57 - Index
Index A AMS Device Manager adding network component 24 using to configure fieldbus devices 29 C change the device class 20 commission fieldbus devices 18 Communication DTM installation 12 configure fieldbus devices using AMS Device Manager 29 using PACTware 33 connect to live fieldbus segment 15 con...