Page 2 - Product Data Sheet; Taking Guided Wave Radar Benefits to the Next Level; MEASUREMENT PRINCIPLE; Smart Galvanic Interface; TM fieldbus. This enables proactive
Product Data Sheet 00813-0100-4530, Rev AA Catalog 2008 - 2009 Rosemount 5300 Series Level-2 Taking Guided Wave Radar Benefits to the Next Level MEASUREMENT PRINCIPLE Rosemount 5300 Series is based on the Time Domain Reflectometry (TDR) technology. Low power nano-second microwave pulses are guided d...
Page 3 - Optimized to Suit More Applications; Solids performance
Product Data Sheet 00813-0100-4530, Rev AACatalog 2008 - 2009 Level-3 Rosemount 5300 Series Optimized to Suit More Applications The Rosemount 5300 offers reliable level measurement benefits for a wider range of applications than ever before. It is suitable for all types of processing industries, oil...
Page 4 - System Integration; HART; fieldbus
Product Data Sheet 00813-0100-4530, Rev AA Catalog 2008 - 2009 Rosemount 5300 Series Level-4 System Integration INPUTS / OUTPUTS The 5300 Series transmitter uses the same two wires for both power supply (see page Level-20) and communication. Measurement data is transmitted as an analog 4-20 mA signa...
Page 5 - The transmitter is available with Intrinsically Safe; DISPLAY; MEASUREMENT PARAMETERS; or any; TM fieldbus and
Product Data Sheet 00813-0100-4530, Rev AACatalog 2008 - 2009 Level-5 Rosemount 5300 Series The transmitter is available with Intrinsically Safe (1) / Non-Incendive or Explosionproof / Flameproof approvals. A safety isolator such as a zener barrier must be used for intrinsic safety. Refer to “Produc...
Page 6 - ADVANCED PLANTWEB
Product Data Sheet 00813-0100-4530, Rev AA Catalog 2008 - 2009 Rosemount 5300 Series Level-6 For 4-20 mA or HART ® , a HART ® modem is required for communication between the transmitter and RadarMaster (part number 03300-7004-0001 for RS232 and 03300-7004-0002 for USB interface). For F OUNDATION ™ f...
Page 7 - or NPT or BSP/G threads; Temperature and Pressure Ratings; High Temperature and High Pressure (HTHP)
Product Data Sheet 00813-0100-4530, Rev AACatalog 2008 - 2009 Level-7 Rosemount 5300 Series TANK CONNECTION The tank connection consists of a tank seal, a flange (1) or NPT or BSP/G threads (2) . See “Ordering Information” on page 32). Flange mating face dimensions follow ANSI B 16.5, JIS B2220, and...
Page 8 - Flange Rating; Ambient Temperature; For guidance in probe selection, see page 10.
Product Data Sheet 00813-0100-4530, Rev AA Catalog 2008 - 2009 Rosemount 5300 Series Level-8 Flange Rating • ANSI:According to ANSI B16.5 Table 2-2.3.Standard: Max. 302 °F/580 psig (150 °C/40 Bar).HP/HTHP: Up to Class 2500. • EN:According to EN 1092-1 Table 18, material group 13E0.Standard: Max. 302...
Page 9 - Transition Zones
Product Data Sheet 00813-0100-4530, Rev AACatalog 2008 - 2009 Level-9 Rosemount 5300 Series Transition Zones Transition zones are areas where measurements are non-linear or will have reduced accuracy. See picture and table below. If measurements are desired at the very top of the tank it is possible...
Page 11 - Measuring Range; Disturbing objects close to the probe.
Product Data Sheet 00813-0100-4530, Rev AACatalog 2008 - 2009 Level-11 Rosemount 5300 Series Measuring Range In the table below, measuring range information is given for each probe. Since the measuring range depends on the application and on the different factors described in this chapter, the value...
Page 12 - Interface; If interface is to be measured, follow these criteria:
Product Data Sheet 00813-0100-4530, Rev AA Catalog 2008 - 2009 Rosemount 5300 Series Level-12 Interface Rosemount 5302 is the ideal choice for measuring the level of oil, and the interface of oil and water, or other liquids with significant dielectric differences. Rosemount 5301 can also be used in ...
Page 13 - Replacing a Displacer in an Existing Displacer Cage; Considerations when changing to 5300
Product Data Sheet 00813-0100-4530, Rev AACatalog 2008 - 2009 Level-13 Rosemount 5300 Series Replacing a Displacer in an Existing Displacer Cage A Rosemount 5300 Series transmitter is the perfect replacement in an existing displacer cage. Proprietary flanges are offered, enabling use of existing cag...
Page 14 - Solids
Product Data Sheet 00813-0100-4530, Rev AA Catalog 2008 - 2009 Rosemount 5300 Series Level-14 Solids Rosemount 5303 is the perfect choice for most solid applications such as powders, granulates, or pellets with a grain size of up to 0.8 in. (20 mm). Material include plastics, fly-ash, cement, sand, ...
Page 15 - Mechanical Considerations
Product Data Sheet 00813-0100-4530, Rev AACatalog 2008 - 2009 Level-15 Rosemount 5300 Series Mechanical Considerations Typically the transmitter is top mounted with a flanged or threaded tank connection, but the probe can also be installed at an angle of up to 90° from vertical. When the transmitter...
Page 17 - Specifications
Product Data Sheet 00813-0100-4530, Rev AACatalog 2008 - 2009 Level-17 Rosemount 5300 Series Specifications General Product Rosemount 5300 Series Guided Wave Radar;Model 5301, Liquid Level or Interface Transmitter (interface available for fully submerged probe).Model 5302 Liquid Level and Interface ...
Page 20 - TM fieldbus; TM fieldbus is; NOTE
Product Data Sheet 00813-0100-4530, Rev AA Catalog 2008 - 2009 Rosemount 5300 Series Level-20 POWER SUPPLY 4-20 mA with HART ® The input voltage (U I )for HART ® is 16-42.4 V dc (16-30 V dc in IS applications, and 20-42.4 V dc in Explosionproof / Flameproof applications). The maximum load resistance...
Page 21 - Product Certifications; ATEX Approval
Product Data Sheet 00813-0100-4530, Rev AACatalog 2008 - 2009 Level-21 Rosemount 5300 Series Product Certifications SAFETY NOTE A safety isolator such as a zener barrier is always needed for intrinsic safety. Probes covered with plastic and/or with plastic discs may generate an ignition-capable leve...
Page 22 - Canadian Standards Association (CSA) Approval; IECEx Approval; Combination Approvals
Product Data Sheet 00813-0100-4530, Rev AA Catalog 2008 - 2009 Rosemount 5300 Series Level-22 Canadian Standards Association (CSA) Approval Cert. no. 1514653 E6 Explosionproof with internal Intrinsically Safe Circuits [Exia] Class I, Div. 1, Groups B, C and D; Temp Code T4. Class II, Div. 1 and 2, G...
Page 23 - Dimensional Drawings; COAXIAL PROBE WITH FLANGE CONNECTION; Dimensions are in inches
Product Data Sheet 00813-0100-4530, Rev AACatalog 2008 - 2009 Level-23 Rosemount 5300 Series Dimensional Drawings COAXIAL PROBE WITH FLANGE CONNECTION L ≤ 20 feet (6 m) 10.1 (255.6) 5.2 (133) 7.1 (180) 3.4 (87) 3.6 (92) 1.1 (28) 7.4 (187) ½ - 14 NPTOptional adapters:M20x1.5, eurofast and minifast Th...
Page 32 - Ordering Information; MODEL CODE 5301 AND 5302 LEVEL AND/OR INTERFACE IN LIQUIDS
Product Data Sheet 00813-0100-4530, Rev AA Catalog 2008 - 2009 Rosemount 5300 Series Level-32 Ordering Information MODEL CODE 5301 AND 5302 LEVEL AND/OR INTERFACE IN LIQUIDS Model Product Description 5301 Guided Wave Radar Liquid Level or Interface Transmitter (interface available for fully submerge...