Page 3 - Reference Manual; Graphical Field Display; NOTICE; Spare Parts
Reference Manual 300560EN, Rev AAMay 2011 Rosemount 2230 www.rosemount-tg.com Rosemount 2230 Graphical Field Display Cover Photo: 2230_coverphoto_2.jpg NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance, make sure you thorough...
Page 5 - Table of Contents
Reference Manual 300560EN, Rev AAMay 2011 TOC-1 Rosemount 2230 Table of Contents Table of Contents SECTION 1Introduction 1.1 Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 7 - Section 1; MESSAGES
Reference Manual 300560EN, Rev AAMay 2011 Rosemount 2230 www.rosemount-tg.com Section 1 Introduction 1.1 Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-1 1.2 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-2 1.3 Manual Overview . ....
Page 8 - Section 1. Introduction
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 1-2 Section 1. Introduction 1.2 SYMBOLS The CE marking symbolizes the conformity of the product with the applicable European Community Directives. The EC-Type Examination Certificate is a statement of a Notified Certification Body declaring t...
Page 9 - OVERVIEW
Reference Manual 300560EN, Rev AAMay 2011 1-3 Rosemount 2230 Section 1. Introduction 1.3 MANUAL OVERVIEW Section 1:Introduction • Manual overview• Product recycling/disposal• Packing material Section 2: Overview • Introduction• 2230 Components• System Overview• Getting started• Installation Procedur...
Page 10 - DOCUMENTATION; The Raptor System includes the following documents:
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 1-4 Section 1. Introduction 1.4 TECHNICAL DOCUMENTATION The Raptor System includes the following documents: • Raptor Technical Description (704010EN)• Rosemount 5900S Reference Manual (300520EN)• Rosemount 2410 Reference Manual (300530EN)• Ro...
Page 11 - MATERIAL; Landfill is not a recycling option and should be avoided.; SEP
Reference Manual 300560EN, Rev AAMay 2011 1-5 Rosemount 2230 Section 1. Introduction 1.5 PRODUCT RECYCLING/ DISPOSAL Recycling of equipment and packaging should be taken into consideration and disposed of in accordance with local and national legislation/regulations. The label below is put on Rosemo...
Page 13 - Section 2; The; Tankbus
Reference Manual 300560EN, Rev AAMay 2011 Rosemount 2230 www.rosemount-tg.com Section 2 Overview 2.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1 2.2 2230 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-2 2.3 System Overview . . . . . ...
Page 14 - components
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 2-2 Section 2. Overview 2.2 2230 COMPONENTS Figure 2-2. Rosemount 2230 components 1. Weather protection lid (1) 2. Display3. Menu4. Soft keys5. Activity indicator6. Cover screw7. Cable entries: two M20 x 1.5 and one M25 x 1.5 (optional: ½ - 1...
Page 15 - The Tankbus is based on a standardized fieldbus, the FISCO
Reference Manual 300560EN, Rev AAMay 2011 2-3 Rosemount 2230 Section 2. Overview 2.3 SYSTEM OVERVIEW Raptor is a state-of-the art inventory and custody transfer radar tank level gauging system. It is developed for a wide range of applications at refineries, tank farms and fuel depots, and fulfills t...
Page 16 - architecture
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 2-4 Section 2. Overview Figure 2-3. Raptor system architecture 2230 Display 2240S Temperature Transmitter 5900S Radar Level Gauge 2410 Tank Hub Tankbus 5300 Level Transmitter 5400 Level Transmitter 3051S Pressure Transmitter TRL2 Modbus Group...
Page 17 - TankMaster HMI Software
Reference Manual 300560EN, Rev AAMay 2011 2-5 Rosemount 2230 Section 2. Overview TankMaster HMI Software TankMaster is a powerful Windows-based Human Machine Interface (HMI) for complete tank inventory management. It provides configuration, service, set-up, inventory, and custody transfer functions ...
Page 18 - Raptor Technical Description
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 2-6 Section 2. Overview Rosemount 5300 Guided Wave Radar The Rosemount 5300 is a premium 2-wire guided wave radar for level measurements on liquids, to be used in a wide range of medium accuracy applications under various tank conditions. Ros...
Page 19 - Field
Reference Manual 300560EN, Rev AAMay 2011 2-7 Rosemount 2230 Section 2. Overview 2.3.1 Raptor System Start-up The standard start-up procedure of a Raptor system that includes devices such as the 2160 Field Communication Unit, 2410 Tank Hub, 5900S Radar Level Gauge, and the 2240S Multi-input Temperat...
Page 20 - Follow these steps for proper installation of the
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 2-8 Section 2. Overview 2.4 INSTALLATION PROCEDURE Follow these steps for proper installation of the Rosemount 2230 Graphical Field Display: 1. Review installation considerations (“Installation Considerations” on page 3-2) 4. Power up the 223...
Page 21 - Section 3
Reference Manual 300560EN, Rev AAMay 2011 Rosemount 2230 www.rosemount-tg.com Section 3 Installation 3.1 Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1 3.2 Mechanical Installation . . . . . . . . . . . . . . . . . . . . . . page 3-2 3.3 Electrical Installation . . ....
Page 22 - Section 3. Installation; INSTALLATION; • When mounting the 2230 display ensure that sufficient space is
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 3-2 Section 3. Installation 3.2 MECHANICAL INSTALLATION 3.2.1 Installation Considerations The Rosemount 2230 Graphical Field Display can be installed either on the tank roof or at the foot of the tank for a flexible and convenient read-out of...
Page 23 - Mounting on a Plate; the 2230 display as illustrated in Figure 3-2.
Reference Manual 300560EN, Rev AAMay 2011 3-3 Rosemount 2230 Section 3. Installation 3.2.2 Mounting the Graphical Display The Rosemount 2230 Graphical Field Display is designed for mounting on a plate, wall, or pipe. Mounting on a Plate The 2230 display can be mounted on a plate by attaching four M4...
Page 24 - Wall Mounting with Bracket
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 3-4 Section 3. Installation Wall Mounting with Bracket The Rosemount 2230 Graphical Field Display can be mounted on a wall by using the optional mounting kit supplied by Rosemount Tank Gauging. 1. Mount the bracket on the wall by using four M...
Page 25 - Pipe Mounting
Reference Manual 300560EN, Rev AAMay 2011 3-5 Rosemount 2230 Section 3. Installation Pipe Mounting The 2230 can be mounted on pipes ranging from diameter 33 to 60 mm by using an optional mounting kit supplied by Rosemount Tank Gauging. 1. Attach the bracket to the pipe.2. Ensure that the 2230 is pla...
Page 26 - The internal ground screw is identified by a ground symbol:
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 3-6 Section 3. Installation 3.3 ELECTRICAL INSTALLATION 3.3.1 Cable/Conduit Entries The electronics housing has three entries, two M20×1.5 and one M25×1.5 (Optional: adapters for two ½ - 14 NPT and one ¾- NPT). Minifast and eurofast adapters ...
Page 27 - TM Fieldbus; Hazardous Areas; Rosemount 2410 Reference Manual
Reference Manual 300560EN, Rev AAMay 2011 3-7 Rosemount 2230 Section 3. Installation Grounding - F OUNDATION ™ Fieldbus Signal wiring of the fieldbus segment must not be grounded. Grounding one of the signal wires will shut down the entire fieldbus segment. Shield Wire Connection To protect the fiel...
Page 28 - Termination; two
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 3-8 Section 3. Installation 3.3.6 The Tankbus The Raptor system is easy to install and wire. Devices can be “daisy-chained” thus reducing the number of segment couplers. In a Raptor system devices communicate with a Rosemount 2410 Tank Hub vi...
Page 29 - fieldbus
Reference Manual 300560EN, Rev AAMay 2011 3-9 Rosemount 2230 Section 3. Installation 3.3.7 Typical installations The example below in Figure 3-4 illustrates a Raptor system with terminators at both ends of the fieldbus segment as required in a F OUNDATION fieldbus system. In this case terminators ar...
Page 32 - Daisy-Chain Connection; Run the new Tankbus cable into the 2230 compartment through a
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 3-12 Section 3. Installation Daisy-Chain Connection You may use the daisy-chain option in order to connect the Rosemount 2230 to other field devices on the Raptor Tankbus: 1. Unscrew and remove all six screws on the front of the Rosemount 223...
Page 33 - RESET BUTTON
Reference Manual 300560EN, Rev AAMay 2011 3-13 Rosemount 2230 Section 3. Installation 3.4 LED SIGNALS AND RESET BUTTON The Rosemount 2230 has three LED signals that show communication and status. Figure 3-8. LED Signals Status LED Using different blinking sequences, the status LED indicates error co...
Page 34 - DIP Switches; The switches control the following settings:; The Simulate Switch; TEMPERATURE
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 3-14 Section 3. Installation 3.5 SWITCHES 3.5.1 DIP Switches The Rosemount 2230 is equipped with four DIP switches as illustrated in Figure 3-9. Figure 3-9. DIP Switches The switches control the following settings: Table 3-2. Rosemount 2230 D...
Page 35 - Section 4
Reference Manual 300560EN, Rev AAMay 2011 Rosemount 2230 www.rosemount-tg.com Section 4 Configuration and Operation 4.1 Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-1 4.2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4-2 4.3 Menu ...
Page 36 - Menu
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 4-2 Section 4. Configuration and Operation 4.2 INTRODUCTION This chapter provides information about configuration and operation of the Rosemount 2230 Graphical Field Display. For information on how to use TankMaster WinSetup to configure the ...
Page 37 - Section 4. Configuration and Operation
Reference Manual 300560EN, Rev AAMay 2011 4-3 Rosemount 2230 Section 4. Configuration and Operation 4.2.2 Activity and Alarm Indication The Rosemount 2230 display shows a warning symbol for simulated or manual measurement values as illustrated in Figure 4-2 and Figure 4-3. Figure 4-2. Simulated or m...
Page 40 - Select View
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 4-6 Section 4. Configuration and Operation 4.5 THE SELECT VIEW MENU In the Select View menu, you can specify the number of measurement values to be displayed in View Mode. To configure the Select View menu: 1. In View Mode, press the <Menu...
Page 41 - Options
Reference Manual 300560EN, Rev AAMay 2011 4-7 Rosemount 2230 Section 4. Configuration and Operation 4.6 THE OPTIONS MENU In the Options Menu, the following items are available: • Variables• Tanks• Units for Display• Toggle Time• Language To choose an item in the Options menu: 1. In View Mode, press ...
Page 42 - Select Variables Menu
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 4-8 Section 4. Configuration and Operation 4.6.1 Variables In the Select Variables menu, you can choose which variables to present in View Mode. The following options are available: • 2410 Tank Pos 1-10 lets you configure a common set of vari...
Page 43 - Select Variables in TankMaster WinSetup; For more information see the
Reference Manual 300560EN, Rev AAMay 2011 4-9 Rosemount 2230 Section 4. Configuration and Operation Table 4-1. Selectable variables Select Variables in TankMaster WinSetup Variables to present in the View Mode can also be configured by using the TankMaster WinSetup configuration program. For more in...
Page 44 - • Default
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 4-10 Section 4. Configuration and Operation 4.6.2 Select Tanks In the Select Tanks menu, you can specify which tanks to show in View Mode. The following items are available: • Default • All which displays all available tanks in View Mode • 24...
Page 47 - Toggle Time; To set the Toggle Time:; Language; To set the display Language:
Reference Manual 300560EN, Rev AAMay 2011 4-13 Rosemount 2230 Section 4. Configuration and Operation 4.6.4 Toggle Time The Toggle Time parameter specifies the time period that each value, or set of values, is presented on the display. To set the Toggle Time: 1. From View Mode, press <Menu> <...
Page 48 - Service
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 4-14 Section 4. Configuration and Operation 4.7 THE SERVICE MENU In the Service Menu, the following items are available: • Status• Custody Transfer View• LCD Test• LCD Contrast• Restart• Factory Settings• About To choose a Service menu item: ...
Page 52 - About; To view the About information:
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 4-18 Section 4. Configuration and Operation 4.7.7 About To view the About information: 1. In View Mode, press <Menu><Service>.2. Choose the About option and press the softkey. Figure 4-30. Software revisions for Rosemount 2230 3. ...
Page 53 - Section 5
Reference Manual 300560EN, Rev AAMay 2011 Rosemount 2230 www.rosemount-tg.com Section 5 Service and Troubleshooting 5.1 Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-1 5.2 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5-2 5.3 Tr...
Page 55 - Input
Reference Manual 300560EN, Rev AAMay 2011 5-3 Rosemount 2230 Section 5. Service and Troubleshooting 5.2.2 Viewing Input and Holding Registers Measured data is continuously stored in the Rosemount 2230 Input Registers. They can be used for verifying that the Rosemount 2230 works properly and for adva...
Page 56 - Section 5. Service and Troubleshooting; Predefined; option lists a basic selection of useful registers.; Start Register; and enter the; Number of Registers; button to update the Value column with the current
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 5-4 Section 5. Service and Troubleshooting 4. The Predefined option lists a basic selection of useful registers. 5. Choose the desired Start Register and enter the Number of Registers to read. 6. Click the Read button to update the Value colu...
Page 58 - Example; Error code 3 is displayed as the following flash sequence:
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 5-6 Section 5. Service and Troubleshooting 5.2.4 Device Error Signals A Light Emitting Diode (LED) inside the 2230 cover is used for presentation of device status using different blinking sequences. Figure 5-3. Error signals In normal operati...
Page 61 - Device Errors; Table 5-4 shows a list of error messages for the
Reference Manual 300560EN, Rev AAMay 2011 5-9 Rosemount 2230 Section 5. Service and Troubleshooting 5.3.1 Device Errors Table 5-4 shows a list of error messages for the Rosemount 2230 . Detailed information about the different error types can be found in Input registers 1100 - 1134 as shown in Table...
Page 62 - Device Warnings; Device warnings are signaled in the Input Register
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 5-10 Section 5. Service and Troubleshooting 5.3.2 Device Warnings Device warnings are signaled in the Input Register Device Warnings. Warnings are less serious than errors. Detailed information about the different warning types can be found i...
Page 65 - Appendix A
Reference Manual 300560EN, Rev AAMay 2011 Rosemount 2230 www.rosemount-tg.com Appendix A Reference Data A.1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1 A.2 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . page A-3 A.3 Ordering Information . ....
Page 66 - Appendix A. Reference Data
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 A-2 Appendix A. Reference Data Environment Ambient temperature -20 to 70 ° C (-4 to 158 ° F) Storage temperature -30 to 85 °C (-22 to 185 ° F) Humidity 0-100% relative humidity, non-condensing Ingress protection IP 66 and 67 (Nema 4) Metrolog...
Page 69 - Appendix B
Reference Manual 300560EN, Rev AAMay 2011 Rosemount 2230 www.rosemount-tg.com Appendix B Product Certifications B.1 Safety messages . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-1 B.2 EU Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-2 B.3 Hazardous Locati...
Page 70 - Appendix B. Product Certifications
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 B-2 Appendix B. Product Certifications B.2 EU CONFORMITY The EC declaration of conformity for all applicable European directives for this product can be found on the Rosemount Tank Gauging web site at www.rosemount-tg.com. A hard copy may be ...
Page 71 - Factory Mutual; Intrinsic Safety US Approval; Special Conditions of Use
Reference Manual 300560EN, Rev AAMay 2011 B-3 Rosemount 2230 Appendix B. Product Certifications B.3 HAZARDOUS LOCATIONS CERTIFICATIONS The Rosemount 2230 Graphical Field Displays that have the following labels attached have been certified to comply with the requirements of the approval agencies note...
Page 72 - Intrinsic Safety Canadian
Reference Manual 300560EN, Rev AA May 2011 Rosemount 2230 B-4 Appendix B. Product Certifications B.3.2 Factory Mutual Canadian Approvals Certificate of Compliance: 3037177C. Figure B-2. Factory Mutual Intrinsic Safety Canadian Approval Label I6 FISCO Field Device (Fieldbus Terminals) Intrinsically S...
Page 73 - European ATEX; Safety Approval Label
Reference Manual 300560EN, Rev AAMay 2011 B-5 Rosemount 2230 Appendix B. Product Certifications B.3.3 European ATEX Directive Information The Rosemount 2230 Graphical Field Displays that have the following labels attached have been certified to comply with Directive 94/9/EC of the European Parliamen...
Page 75 - IECEx Approval
Reference Manual 300560EN, Rev AAMay 2011 B-7 Rosemount 2230 Appendix B. Product Certifications B.3.4 IECEx Approval Figure B-4. IECEx Intrinsic Safety Approval Label I7 The following information is provided as part of the label of the transmitter: • Name and address of the manufacturer (Rosemount)•...
Page 77 - Index; Numerics
Reference Manual 300560EN, Rev AAMay 2011 Rosemount 2230 www.rosemount-tg.com Index Numerics 2160 Field Communication Unit . 2-5 2410 . . . . . . . . . . . . . . . . . . . . . . 2-5 2410 Tank Hub . . . . . . . . . . . . . . 2-5 5300 Guided Wave Radar . . . . . 2-6 5400 Radar Level Transmitter . . 2-...