Page 3 - C o n t e n t s
PMC-CGM Installation and Use (6806800D53C) 3 About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Safety Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 5 - L i s t o f Ta bl e s
PMC-CGM Installation and Use (6806800D53C) 5 Table 1-1 Standard Compliances and Clocking Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Table 1-2 Available Board Variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Table 2-...
Page 7 - L i s t o f F i g u r e s
PMC-CGM Installation and Use (6806800D53C) 7 Figure 1-1 PMC-CGM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 2-1 Switch Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 9 - About this Manual; Overview of Contents
PMC-CGM Installation and Use (6806800D53C) 9 About this Manual Overview of Contents This manual is divided into the following chapters and appendices. z Safety Notes on page 13 provides safety relevant information when handling the product. z Sicherheitshinweise on page 17 provides a German translat...
Page 11 - Conventions
About this Manual PMC-CGM Installation and Use (6806800D53C) 11 Conventions The following table describes the conventions used throughout this manual. TPE Twisted-Pair Ethernet UL Underwriters Laboratories Incorporated VCCI Voluntary Control Council for Interference VLAN Virtual Local Area Network A...
Page 12 - Summary of Changes; Comments and Suggestions
PMC-CGM Installation and Use (6806800D53C) About this Manual 12 Summary of Changes This manual has been revised and replaces all prior editions. Comments and Suggestions We welcome and appreciate your comments on our documentation. We want to know what you think about our manuals and how we can make...
Page 13 - Safety Notes; Electrical Interference
PMC-CGM Installation and Use (6806800D53C) 13 Safety Notes This section provides warnings that precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed during all phases of operation, service, and repair of this equipment. You should al...
Page 14 - Operation
PMC-CGM Installation and Use (6806800D53C) Safety Notes 14 Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by Emerson coul...
Page 15 - Configuration Switches; Environment
Safety Notes PMC-CGM Installation and Use (6806800D53C) 15 Emerson and our suppliers take significant steps to ensure there are no bent pins on the backplane or connector damage to the boards prior to leaving the factory. Bent pins caused by improper installation or by inserting boards with damaged ...
Page 17 - Sicherheitshinweise; EMV
PMC-CGM Installation and Use (6806800D53C) 17 Sicherheitshinweise Dieses Kapitel enthält Hinweise, die potentiell gefährlichen Prozeduren innerhalb dieses Handbuchs vorrangestellt sind. Beachten Sie unbedingt in allen Phasen des Betriebs, der Wartung und der Reparatur des Systems die Anweisungen, di...
Page 19 - Schaltereinstellungen
Sicherheitshinweise PMC-CGM Installation and Use (6806800D53C) 19 Emerson und unsere Zulieferer unternehmen größte Anstrengungen um sicherzustellen, dass sich Pins und Stecker von Boards vor dem Verlassung der Produktionsstätte in einwandfreiem Zustand befinden. Verbogene Pins, verursacht durch fehl...
Page 21 - Introduction; Features
1 PMC-CGM Installation and Use (6806800D53C) 21 Introduction 1.1 Features The Clock Generator Module (PMC-CGM) is a PMC module which is either available together with the Emerson ATCA-F103 switch or as part of an accessory kit. It can only be used in conjunction with the ARTM-F103-STX. The PMC-CGM i...
Page 22 - Standard Compliances
PMC-CGM Installation and Use (6806800D53C ) Introduction Standard Compliances 22 The following graphic shows the PMC-CGM. 1.2 Standard Compliances The PMC-CGM, when installed in a compliant chassis, meets the following standards: Figure 1-1 PMC-CGM Table 1-1 Standard Compliances and Clocking Standar...
Page 23 - Ordering Information
Ordering Information Introduction PMC-CGM Installation and Use (6806800D53C) 23 1.3 Ordering Information As of the printing date of this manual, this guide supports the boards model listed below. G.703 BITS interface G.813 TR-1244 Clock quality ANSI/IPC-A610 Rev.C Class 2 ANSI/IPC-7711 ANSI/IPC-7721...
Page 25 - Hardware Preparation and Installation; Overview; Unpacking and Inspecting the Module; Shipment Inspection
2 PMC-CGM Installation and Use (6806800D53C) 25 Hardware Preparation and Installation 2.1 Overview In this section, you can find information on the following topics: z Things to observe before the installation z Installation procedure z Available accessories 2.2 Before Installation This section prov...
Page 26 - Requirements; Environmental Requirements
PMC-CGM Installation and Use (6806800D53C ) Hardware Preparation and Installation Requirements 26 2. Check for damage and report any damage or differences to the customer service. 3. Remove the desiccant bag shipped together with the module and dispose of it according to your country’s legislation. ...
Page 27 - Power Requirements
Requirements Hardware Preparation and Installation PMC-CGM Installation and Use (6806800D53C) 27 2.2.2.2 Power Requirements Make sure that the module is only used on an ATCA-F103 blade in an AdvancedTCA shelf connected to -48VDC up to -60VDC (rated voltage), according to Telecommunication Network Vo...
Page 28 - Configuring the Module
PMC-CGM Installation and Use (6806800D53C ) Hardware Preparation and Installation Configuring the Module 28 2.3 Configuring the Module The module provides the configuration switch SW1 as shown in the following figure. The switch settings shown in the figure correspond to the default settings. The sw...
Page 29 - Installing and Removing the Module
Installing and Removing the Module Hardware Preparation and Installation PMC-CGM Installation and Use (6806800D53C) 29 2.4 Installing and Removing the Module The PMC-CGM can be installed on the PMC slot of the AdvancedTCA ATCA-F103 blade. Table 2-3 Switch Settings Switch Description SW1-1 Reserved (...
Page 30 - Installation Procedure; Removal Procedure; Hardware Upgrades and Acessories
PMC-CGM Installation and Use (6806800D53C ) Hardware Preparation and Installation Hardware Upgrades and Acessories 30 Before installing an PMC module observe the following notes. Installation Procedure To install the PMC module, proceed as follows: 1. Remove the blind panel from the PMC slot of the ...
Page 31 - Controls, LEDs and Connectors; Layout; Front Panel Connectors and LEDs
3 PMC-CGM Installation and Use (6806800D53C) 31 Controls, LEDs and Connectors 3.1 Overview This chapter describes: z Layout z Front panel connectors and LEDs 3.2 Layout The following figure shows the main components of the PMC-CGM. 3.3 Front Panel Connectors and LEDs At the front panel of the PMC-CG...
Page 32 - BITS Interface Connectors
PMC-CGM Installation and Use (6806800D53C ) Controls, LEDs and Connectors BITS Interface Connectors 32 The Ethernet ports for the PMC-CGM are located on the ARTM-F103. 3.3.1 BITS Interface Connectors The module provides two RJ-45 BITS front panel connectors. Figure 3-2 Front Panel Product DamageThe ...
Page 33 - LEDs
LEDs Controls, LEDs and Connectors PMC-CGM Installation and Use (6806800D53C) 33 You can find the signal description of the the BITS connectors in the following figure where x is the number of the BITS connector. 3.3.2 LEDs The product provides the following LEDs. Figure 3-3 BITS Connector Location ...
Page 35 - Access and Configuration; Accessing the PMC-CGM
4 PMC-CGM Installation and Use (6806800D53C) 35 Access and Configuration 4.1 Overview In this chapter, you can find information on the following topics: z How to access the module. z What to observe when using a MIB browser. z How to configure the module. 4.2 Accessing the PMC-CGM To access the modu...
Page 36 - Cabling
PMC-CGM Installation and Use (6806800D53C ) Access and Configuration Cabling 36 4.2.1 Cabling To access the PMC-CGM, you have to attach an Ethernet cable to the ARTM-F103-STX as shown in the following graphic. It is mandatory that you connect port ETH7 with ETHA on the same ARTM-F103-STX and that yo...
Page 37 - Using a MIB Browser
Using a MIB Browser Access and Configuration PMC-CGM Installation and Use (6806800D53C) 37 4.3 Using a MIB Browser When you are using a MIB browser to configure the PMC-CGM, you have to use the following settings. 4.4 Configuring the PMC-CGM To configure the PMC-CGM, you can perform the following ta...
Page 38 - Define IP Address of the Protection Partner Module; Defining the IP address of the protection partner module; Define SNMP Trap Destinations; Defining SNMP Trap Destinations
PMC-CGM Installation and Use (6806800D53C ) Access and Configuration Define IP Address of the Protection Partner Module 38 You can perform these tasks independently from each other. 4.4.1 Define IP Address of the Protection Partner Module The PMC-CGM modules usually work in a master/slave configurat...
Page 39 - Configure the Interface Mode; Configuring the interface mode; Configure the BITS Interface; Configuring the BITS interface
Configure the Interface Mode Access and Configuration PMC-CGM Installation and Use (6806800D53C) 39 4.4.3 Configure the Interface Mode You can chose between SONET/T1 and SDH/E1 mode via the MIB object cgmInterfaceMode OID: .1.3.6.1.4.1.3656.8152.1.1.10.0. The modes are used in different regions. Thi...
Page 40 - Configure Initial Master/Slave Role; Configuring the initial master/slave roles; Setup Multi-Shelf Configuration; Setting up a multi-shelf configuration
PMC-CGM Installation and Use (6806800D53C ) Access and Configuration Configure Initial Master/Slave Role 40 4.4.5 Configure Initial Master/Slave Role After the initial configuration, the master/slave roles are handled by the DPLL software that runs on the processor of the PMC-CGM. Configuring the in...
Page 41 - Configure the Reference Clock; Configuring the reference clock source for the T0/T4 path
Configure the Reference Clock Access and Configuration PMC-CGM Installation and Use (6806800D53C) 41 4.4.7 Configure the Reference Clock You can define the reference clock source, the frequency and the priority of the reference clock inputs. For a description of the respective MIB objects refer to T...
Page 42 - Perform Firmware/Software Upgrade; Upgrading the firmware/software
PMC-CGM Installation and Use (6806800D53C ) Access and Configuration Perform Firmware/Software Upgrade 42 7. For the T4 path, repeat steps 5 and 6 with the cgmT4InputPriority object OID:.1.3.6.1.4.1.3656.8152.1.1.1.1.5.<instance number which is equal to input number -1>. 8. Go to cgmInputRefAS...
Page 43 - Resetting the PMC-CGM via SNMP
Reset the PMC-CGM Access and Configuration PMC-CGM Installation and Use (6806800D53C) 43 8. Enter the checksum (hexadecinal format) of the new image which is contained in the .md5 file delivered together with the new image.This checksum is verified after downloading the TFTP image and after programm...
Page 44 - Configure Parameters for Event Handling; Configuring event handling parameters
PMC-CGM Installation and Use (6806800D53C ) Access and Configuration Configure Parameters for Event Handling 44 4. Set object to restart (1). 4.4.10 Configure Parameters for Event Handling You can use the following elements as parameters to define how events are handled in your system. z cgmSysEvent...
Page 47 - MIB Description
5 PMC-CGM Installation and Use (6806800D53C) 47 MIB Description 5.1 Overview You can use the CGM-CONTROL-MIB to access and control the clock generator module PMC-CGM that is used in your AdvancedTCA system. It is located at .iso.org.dod.internet.private.enterprises.forceComputers.cgmControlMIB.motCg...
Page 55 - cgmSys
cgmSys MIB Description PMC-CGM Installation and Use (6806800D53C) 55 5.3 cgmSys The cgmSys branch contains the following information: z cgmEventTable - for details refer to Table 5-6 on page 55 . z Various MIB objects that are described in Table 5-8 on page 58 . For a description on how to use these...
Page 60 - cgmClkDist
PMC-CGM Installation and Use (6806800D53C ) MIB Description cgmClkDist 60 5.4 cgmClkDist The cgmClkDist branch contains the following information which is used for controlling clock distribution and measurement: z cgmDmClkTable - not supported for the PMC-CGM. z cgmFrqMonTable - not supported for th...
Page 63 - Related Documentation; Related Specifications
A PMC-CGM Installation and Use (6806800D53C) 63 A Related Documentation A.1 Emerson Network Power - Embedded Computing Documents The Emerson Network Power - Embedded Computing publications listed below are referenced in this manual. You can obtain electronic copies of Emerson Network Power - Embedde...
Page 65 - I n d ex
PMC-CGM Installation and Use (6806800D53C) 65 A Abbreviations 9 Access 35 Cabling 36 IP addresses 37 Via IPMI 36 Via MIB browser 37 ATCA-F103 21 PMC slot on 29 PMC-CGM support on 21 B BITS interface 32 Configuration 39 Connector 33 LEDs 34 MIB objects 49 Blind panel 30 C Clock distribution cable 30 ...