i TABLE OF CONTENTS 1.0 E MERSON N ETWORK P OWER R ACK PDU S YSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Safety and Agency Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.0 D ETERMINING THE R IGHT E MERSON ...
Page 4 - ii; FIGURES
ii FIGURES Figure 1 Knurr DI-STRIP 35351011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 2 Knurr DI-STRIP 35351021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 5 - Emerson Network Power Rack PDU Systems; MERSON; PDU S; YSTEMS; Knurr; ities and connectivity solutions in a robust package.; Liebert MPH; Safety and Agency Compliance; in this specification will govern.
Emerson Network Power Rack PDU Systems 1 1.0 E MERSON N ETWORK P OWER R ACK PDU S YSTEMS Emerson Network Power’s Rack PDU Systems is a family of products that delivers power and man- agement to connected IT equipment through a global and comprehensive offering including Basic, Managed and Adaptive R...
Page 6 - Determining the Right Emerson PDU for Your Application; PDU
Determining the Right Emerson PDU for Your Application 2 2.0 D ETERMINING THE R IGHT E MERSON PDU FOR Y OUR A PPLICATION Each of the Rack PDU systems Emerson offers is well-suited for delivering power to sensitive, high- capacity, rack-mounted equipment. Determining which is best for a particular in...
Page 7 - Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs; Overview - Basic Rack PDUs; fit should be confirmed for each application.
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 3 3.0 K NURR DI-STRIP P RODUCT S ELECTION G UIDE - B ASIC R ACK PDU S 3.1 Overview - Basic Rack PDUs The Knurr DI-STRIP, a Basic Rack PDU system, provides a broad range of power distribution capaci- ties and connectivity solutions in a robust ...
Page 8 - Basic Rack PDU Optional Accessories; Output Cord Sets; Output Cord Sets - Power Output Expansion
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 4 3.2 Basic Rack PDU Optional Accessories Output Cord Sets Output cord sets versions are available to support conversion of Rack PDU power output receptacles to alternative power output connections and to support Rack PDU output expansion capa...
Page 9 - DImensional Drawings - Basic Rack PDUs; Figure 1
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 5 3.3 DImensional Drawings - Basic Rack PDUs Figure 1 Knurr DI-STRIP 35351011
Page 10 - Figure 2
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 6 Figure 2 Knurr DI-STRIP 35351021
Page 11 - Figure 3
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 7 Figure 3 Knurr DI-STRIP 35351031
Page 12 - Figure 4
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 8 Figure 4 Knurr DI-STRIP 35351041
Page 13 - Figure 5
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 9 Figure 5 Knurr DI-STRIP 35351051
Page 14 - Figure 6
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 10 Figure 6 Knurr DI-STRIP 35351061
Page 15 - Figure 7
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 11 Figure 7 Knurr DI-STRIP 35351081
Page 16 - Figure 8
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 12 Figure 8 Knurr DI-STRIP 35352011
Page 17 - Figure 9
Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 13 Figure 9 Knurr DI-STRIP 35352021
Page 31 - Liebert MPH Product Selection Guide - Managed Rack PDUs; MPH P; Overview - Managed Rack PDUs; form factors and are painted black.; Liebert MPH – Managed Rack PDUs – ALL Liebert MPH Systems; PDU Array; Rack PDU Optional Accessories; for further details. Each Liebert MPH unit is provided with
Liebert MPH Product Selection Guide - Managed Rack PDUs 27 4.0 L IEBERT MPH P RODUCT S ELECTION G UIDE - M ANAGED R ACK PDU S 4.1 Overview - Managed Rack PDUs The Liebert MPH Managed Rack PDU system delivers power distribution, branch monitoring and receptacle control for IT devices. Liebert MPH Rac...
Page 32 - Specifications - Liebert MPH
Liebert MPH Product Selection Guide - Managed Rack PDUs 28 4.2 Specifications - Liebert MPH Part Number INPUT OUTPUT Form Factor Voltage Rated Amps Max. Continuous Amps kW* Phase Plug Receptacle/Socket Configuration Branch Monitoring MPH-NBR09AXXC30 120 20 16 1.9 1 NEMA L5-20 (9) NEMA 5-20R T-Slot R...
Page 33 - Model Number Configuration - Liebert MPH; MPH; Managed Rack PDU Optional Accessories; Cable Restraints - MPH Vertical Systems with IEC-C13 receptacles
Liebert MPH Product Selection Guide - Managed Rack PDUs 29 4.3 Model Number Configuration - Liebert MPH Example: MPH N B R 09 AX XC 30 • Prefix: MPH • Region: N = North America • Type: B = Branch Monitoring C = Controlled Receptacles • Mounting: V = Vertical R = Rack mount • Output Power: • Quantity...
Page 34 - DImensional Drawings - Managed Rack PDUs; Figure 23 Liebert MPH power strip
Liebert MPH Product Selection Guide - Managed Rack PDUs 30 4.5 DImensional Drawings - Managed Rack PDUs Figure 23 Liebert MPH power strip
Page 35 - Figure 24 Liebert MPH power strip
Liebert MPH Product Selection Guide - Managed Rack PDUs 31 Figure 24 Liebert MPH power strip
Page 36 - Liebert MPX - Adaptive Rack PDUs; IEBERT; Overview - Adaptive Rack PDUs
Liebert MPX - Adaptive Rack PDUs 32 5.0 L IEBERT MPX - A DAPTIVE R ACK PDU S 5.1 Overview - Adaptive Rack PDUs The Liebert MPX Adaptive Rack PDU system delivers break-through flexibility, availability and total cost of ownership. The Liebert MPX enables users to respond to and manage changing rack p...
Page 38 - with positioning for future MPX BRM module additions.
Liebert MPX - Adaptive Rack PDUs 34 5.2 MPX PRC (Power Rail Chassis) The MPX PRC distributes power and communications to the installed Liebert MPX modules. The MPX PRC supports both single-phase power input up to 20A and three-phase up to 60A. It includes provisions to mount and secure an input powe...
Page 39 - reset. One MPX PEM is required per Liebert MPX Rack PDU.; Variable Capacity; typical 42U racks. All MPX BRMs are 266mm in length.
Liebert MPX - Adaptive Rack PDUs 35 5.3 MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord) The MPX PEM provides input power to the Liebert MPX system and includes provisions for addition of the Liebert RPC (Rack PDU Card) to support remote and local communications. The MPX PEM is available ...
Page 40 - Adaptive Rack PDU Optional Accessories; Part Numbers for Liebert RPC and Accessories; Integrated Environmental Sensors:
Liebert MPX - Adaptive Rack PDUs 36 5.5 Adaptive Rack PDU Optional Accessories 5.5.1 Output Cord Sets Output cord sets versions are available to support conversion of Rack PDU power output receptacles to alternative power output connections and to support Rack PDU output expansion capabilities.Conve...
Page 41 - shows the four individual ports on the Liebert RPC.; Figure 27 Liebert RPC ports; The Liebert RPC offers the following capabilities and benefits:
Liebert MPX - Adaptive Rack PDUs 37 5.5.4 Ports on the Liebert RPC Figure 27 shows the four individual ports on the Liebert RPC. Each port is designed for only one type of connection. See the Liebert RPC user manual, SL-20825, for details on using these ports. Figure 27 Liebert RPC ports 5.5.5 Liebe...
Page 42 - ries; RPC BDM
Liebert MPX - Adaptive Rack PDUs 38 5.5.6 RPC BDM—Basic Display Module The RPC BDM is an optional device with an LCD for local viewing of status and alarms of up to four Liebert MPX or Liebert MPH PDUs. It connects to Liebert RPC with a factory-supplied cable that is 6.5 ft. (2m) long. The portable ...
Page 43 - tored over a network.; Figure 29 Temperature/humidity sensor
Liebert MPX - Adaptive Rack PDUs 39 5.5.7 Temperature/Humidity Sensor A temperature/humidity sensor is available to monitor conditions in the rack. The sensor mounts without tools. It connects to the Liebert RPC with a factory-supplied Ethernet cable and can be moni- tored over a network. Figure 29 ...
Page 44 - Liebert MPX System Product Selection Guide; MPX S; YSTEM; • The appropriate table in; Specifications - MPX PRC; MPXPRC; Max 17.2 kW, limited to 6 MPX BRM modules
Liebert MPX System Product Selection Guide 40 6.0 L IEBERT MPX S YSTEM P RODUCT S ELECTION G UIDE 6.1 STEP 1 - Select an MPX PRC (Quantity x 1) To select an MPX PRC (Power Rail Chassis), refer to: • The appropriate table in 6.5 - System Selection Guide : • Table 1 - Selections for Power Entry Module...
Page 45 - Capacity MPX PEM system—refer to:; Specifications - MPX PEM; MPXPEM
Liebert MPX System Product Selection Guide 41 6.2 STEP 2 - Select an MPX PEM / MPX IPC (Quantity x 1) To select an MPX PEM (Power Entry Module)—and an MPX IPC (Input Power Cord) for a Variable Capacity MPX PEM system—refer to: • The appropriate table in 6.5 - System Selection Guide for the MPX PEM (...
Page 46 - Specifications - MPX IPC (MPX PEM Variable Capacity Systems ONLY); MPXIPC
Liebert MPX System Product Selection Guide 42 Specifications - MPX IPC (MPX PEM Variable Capacity Systems ONLY) Model Number Configuration - MPX IPC (MPX PEM Variable Capacity Systems ONLY) Example: MPXIPC-NXG30XXX • Prefix: MPXIPC • Region: N = North America • Input Power & Connection: • Plug T...
Page 47 - STEP 3 - Select an MPX BRM; Model Number Configuration - MPX BRM; MPX PRC selected; MPX BRM modules maximum; MPX BRM
Liebert MPX System Product Selection Guide 43 6.3 STEP 3 - Select an MPX BRM To select an MPX BRM (Branch Receptacle Module), refer to: • The appropriate table in 6.5 - System Selection Guide for the MPX PEM (Power Entry Module): • Table 1 - Selections for Power Entry Module MPXPEM-NVAXXAXX • Table ...
Page 48 - STEP 4 - Select Communication Options; Choose from the following options for the Liebert MPX:
Liebert MPX System Product Selection Guide 44 6.4 STEP 4 - Select Communication Options Choose from the following options for the Liebert MPX: • Liebert RPC (Rack PDU Card) part number: • RPC-1000 • RPC BDM (Basic Display Module) part number: • RPC-BDM-1000 • Liebert SN Integrated Environmental Sens...
Page 49 - System Selection Guide; Table 1; Variable
Liebert MPX System Product Selection Guide 45 6.5 System Selection Guide Use the appropriate table as a guide to select components that are compatible with each MPX PEM: • Table 1 - Selections for Power Entry Module MPXPEM-NVAXXAXX • Table 2 - Selections for Power Entry Module MPXPEM-NHBXVA30 • Tabl...
Page 51 - Table 2
Liebert MPX System Product Selection Guide 47 Table 2 Selections for Power Entry Module MPXPEM-NHBXVA30 MPX PEM Part Number Module Voltage Rated Amps Max. Continuous Amps Input Connection Input Phases Module Length (mm) MPXPEM-NHBXVA30 208-240 50 40 CS83665C 3-PH, 4-Wire L1-L2-L3-G 266 Compatible MP...
Page 52 - Table 3
Liebert MPX System Product Selection Guide 48 Table 3 Selections for Power Entry Module MPXPEM-NHBXWA30 MPX PEM Part Number Module Voltage Rated Amps Max. Continuous Amps Input Connection Input Phases Module Length (mm) MPXPEM-NHBXWA30 208-240 60 48 IEC60309 3-PH, 5-Wire L1-L2-L3-N-G 266 Compatible ...
Page 53 - Specifications for Liebert MPX Components; Table 4; or
Liebert MPX System Product Selection Guide 49 6.6 Specifications for Liebert MPX Components Table 4 Specifications - MPX BRM MPX BRM (Branch Receptacle Module)Single-Phase Liebert MPX System (MPX PEM) Input SelectionsPhase L1 to Neutral (120VAC) OutputBranch Monitoring Support MPXBRM-NBBA6A1N Branch...
Page 54 - DImensional Drawings - Adaptive Rack PDUs; Figure 30 Liebert MPX MPXPRC-1035mm mixed modules
Liebert MPX System Product Selection Guide 50 6.7 DImensional Drawings - Adaptive Rack PDUs Figure 30 Liebert MPX MPXPRC-1035mm mixed modules
Page 55 - Figure 31 Liebert MPX MPXPRC-1880mm mixed modules
Liebert MPX System Product Selection Guide 51 Figure 31 Liebert MPX MPXPRC-1880mm mixed modules
Page 56 - Notes
Liebert MPX System Product Selection Guide 52 Notes
Page 60 - AC Power; Technical Support / Service; Via Leonardo Da Vinci 8
EmersonNetworkPower.com Ensuring The High AvailabilityOf Mission-Critical Data And Applications. Emerson Network Power, the global leader in enabling business-criticalcontinuity, ensures network resiliency and adaptability througha family of technologies—including Liebert power and coolingtechnologi...