Page 2 - GENERAL SAFETY INSTRUCTIONS; Limited Warranty; Sales receipt required as proof of purchase for warranty claims.; Safety Signal Words
GENERAL SAFETY INSTRUCTIONS Limited Warranty All products covered by this Owner’s Manual are warranted against defects in workmanship and materials for one year from the date of sale except for motors,which are warranted for two years. This warranty does not apply to damage fromaccident, misuse or a...
Page 3 - Description; Know Your Humidifier
Description HD1205/HD1211 Output/24 hrs 12 Gallons/45 Litres Capacity of Tank 4.5 Gallons/17.0 Litres * Sq. Ft. Coverage 2500 Fan Speeds Three Filters Set of 4 (HDC411) Fill Light Yes Auto Humidistat Yes Auto Shut Off Yes Manual Dryout Yes (see page 7) Controls Rotary CUL Listed Yes Volts 120 A.C. H...
Page 4 - Humidifier Operations; Assembly
Humidifier Operations Your new Emerson humidifier is designed tosatisfy home humidity requirements throughthe principle of evaporation of water into the air. After water is added to the tank the filtersbegin to soak up the water and becometotally saturated in approximately 30 min-utes. Air is drawn ...
Page 5 - Location Instructions
WARNING : For your own safety, do not use humidifier if any parts aredamaged or missing. Step 1 Place humidifier on a flat level surface inarea of house where most humidity isneeded, or an area which would likelyresult in moist air being circulated through-out the house, such as near a cold air retu...
Page 6 - Water Fill
WARNING : To reduce the risk of shock, always unplug humidifierbefore filling, cleaning or servicing. WARNING : To reduce the risk of fire or shock hazard, do not pour or spillwater into control or motor area.Close the control cover. If control getwet, let them dry completely and haveunit checked by...
Page 7 - Operating Humidifier Controls; To Operate the Controls; Air Flow Control; Manual Dryout
7 Operating Humidifier Controls The operating controls of your Emersonevaporative humidifier are located on the topcenter of the humidifier. The controls arefound under the smoked cover, locatedbetween the air circulating fans. Lift the con-trol cover by placing your finger in the roundcutout and li...
Page 8 - Relative Humidity; Using Your Humidifier; Operating Tips for Best Performance
8 R el .H u m id it y Rel. H umidity R el. H u m id ity MAX MIN Relative Humidity Using Your Humidifier Step 1 Be sure unit is full of water and plugged in. Step 2 Set air flow control to desired setting. Step 3 Set Humidity Control to medium position(half way between and ) NOTE: Humidifier should o...
Page 9 - Replacement and Care of Filters
9 Replacement and Care of Filters WARNING: To reduce the risk ofshock or injury from moving parts,always unplug humidifier beforeremoving or replacing any parts. CAUTION: To help retard bacteriagrowth and keep maximum efficien-cy, the filters should be replaced atleast once a season, or more oftenun...
Page 10 - Replacement and Care of Filters (continued)
5. a. Install new filters (Emerson HDC411) in the bottom of the cabinet. b. Reposition top filter housings on top of filters and snap into front filterhousings. c. Position fan assembly onto the cab- inet. Make sure the fan venturi (low-est cylinder section below the fan) isplaced inside the top fil...
Page 11 - To Remove Parts; Cleaning Your Humidifier
CAUTION: To reduce the risk ofinjury, fire or damage to humidifier,use only cleaners specifically rec-ommended for humidifiers. Neveruse flammable, combustible or poi-sonous materials to clean yourhumidifier. To reduce the risk ofscalds and damage to humidifier,never put hot water in humidifier. CAU...
Page 12 - Bi-Weekly Maintenance; End of Season Maintenance
Bi-Weekly Maintenance Removing Scale 1. Fill the humidifier cabinet with one 8 oz. cup of undiluted white vinegar. Let solu-tion stay 20 minutes. 2. Clean all interior surfaces with soft brush. Dampen a soft cloth with undiluted whitevinegar and wipe out the humidifier cabi-net and front filter hous...
Page 13 - Troubleshooting; FOR TECHNICAL HELP
Troubleshooting PROBABLE CAUSE • No power• Selected humidity level has been established • Float is not free• Float retainer positioned in top slot at back of cabinet • This is normal • Dirty filters • Too much water added • Water splashing during filling TROUBLE Unit will not run andFill Light is no...
Page 14 - Parts List for Emerson Humidifier; Repair Parts
Parts List for Emerson Humidifier Model No. HD1205 0 & HD1211 1 14 Repair Parts 24 22 21 19 18 18 20 20 19 21 16 22 1 2 3 4 5 6 8 7 9 25 26 27 10 11 12 13 14 15 16 17 16 24 SP6471-1 HD1205.1211 - 71157 7/12/05 2:08 PM Page 14
Page 15 - For More information about Emerson; Moist; AIR; humidifiers
15 † * Standard Hardware Item - May be purchased locally.† Stock Item - Purchase locally or call 1-800-654-3545 from the USA or 1-866-808-6500 from Canada to order. To order parts call: USA 1-800-654-3545 Canada 1-866-808-6500 Key No. 123456789 101112131415161718192021222324252627 Description Cover ...
Page 16 - FOR TECHNICAL HELP, CALL
© 2002, 2004 EmersonPart No. SP6471 Form No. SP6471 Printed in Canada 11/04 FOR TECHNICAL HELP, CALL (800) 654-3545 FROM USA OR (888) 744-4687 FROM CANADA (Please have complete model number) 9999 Highway 48Markham, Ontario Canada L3P 3J3 TM SP6471-1 HD1205.1211 - 71157 7/12/05 2:08 PM Page 16