Emerson MicroCEM- Manuals
Emerson MicroCEM– User Manual, Manual in PDF format online.
Manuals:
User Manual Emerson MicroCEM
Summary
Page 2 Housing The housing is equipped with a weather-resistantNEMA 4X-rated enclosure and can handle ambienttemperatures between -30 to 50°C. The housing iscompletely piped and wired and is accessible via bulk-head and terminal block termination points. All internalsample lines, fittings and valvin...
Page 3 Analysis Enclosure The MicroCEM design includes an analysis enclosurewhich can be located at the sampling location at thebottom of the stack or in an environmental location.This enclosure is rated NEMA 4X and can be mountedbeside the sample conditioning enclosure or remotely upto 300’ away (2...
Page 5 Power: Universal power supply 85 to 125VAC, 50 to 60 Hz, +/-10%1000 watts maximum at start up,500 watts nominal Microprocessor: Intel Celeron processor, 556MHz,64MB RAM, PC/104 architecture,Microsoft ® Windows NT-embedded platform Display: Pocket PC: 206MHz, StrongArmprocessor, 32MB RAM, 32MB...
Page 6 Power: Universal power supply 85 to125 VAC, 50 to 60 Hz, +/-10%750 watts maximum atstart up. 500 watts nominal Mounting: Customer flange mount(2 hole tap or wall mount forhigh temp. option) Area Classification: General purpose / NEMA 4X(IP 65) fiberglass enclosure Compliances: CSA (Pending) A...
Page 7 EXAMPLE MENU SCREENS Settings 2 Limits File Tools Advanced Auto Cal. Freq. Auto Cal. Range O 2 Output Range Range 2 25.00 % Range 1 5.00 % CO Output Range Range 2 250.00 ppm Range 1 25.00 ppm NO Output Range Range 2 100.00 ppm Range 1 25.00 ppm Calibration Bottle Settings LoMid 5.50 99.61 55....
Page 8 Model Description UCEMS MicroCEM PC104-Controlled O 2 /CO/NO x CEM in a NEMA 4X Enclosure (UCEMS) Level 1 Channel 1 11 Single Channel Paramagnetic O 2 (0-25%) 12 Single Channel NDIR CO (Low range 0–10 ppm) 13 Single Channel Chemiluminescent NO x 14 Single Channel Electrochemical O 2 (0-25% ra...
Page 10 Model Description USHS MicroCEM Probe/Sample Handling System (USHS) Level 1 Standard Interior Sample Handling System, In Fiberglass Enclosure 01 Standard SHS - Dual pass chiller, standard 4” 150 lb. flange, 4’ probe, for applications to 400°F 02 Standard SHS with 600°F option - Includes spoo...
Emerson Process Management Rosemount Analytical Inc.Process Analytic Division1201 N or t h M a in S tree tO rr v i l le, O H 4 4 6 67-0 9 01 U S AT 3 3 0.6 82.9 010To ll Fre e i n U S a n d C a n a d a 8 0 0 .4 3 3.6 076F 3 3 0.6 8 4.4 4 3 4e-m a il: g a s .c s c@ EmersonProcess.c o m www.raihome.co...
Manual Emerson MicroCEM
Emerson Manuals
-
Emerson LD195EM8
User Manual
-
Emerson EWR20V4
User Manual
-
Emerson EWR20V4
Manual
-
Emerson SLC195EM8
User Manual
-
Emerson SLC195EM8
Manual
-
Emerson CR202EM9
User Manual
-
Emerson HD14070
User Manual
-
Emerson RLC320EM9
User Manual
-
Emerson LC320EM9
User Manual
-
Emerson LC320EM9
Manual
-
Emerson PD6922
User Manual
-
Emerson PD6922
Manual
-
Emerson EPT427D
User Manual
-
Emerson EPT427D
Manual
-
Emerson 400 VMC
User Manual
-
Emerson 400 VMC
Manual
-
Emerson CF960CK
User Manual
-
Emerson MICRO MOTION 2700
Installation Manual
-
Emerson CF787AP00
User Manual
-
Emerson CF787AP00
Manual