Page 2 - Table of Contents; Page; How To Install a White-Rodgers; This humidifier must be installed by a qualified professional; and/or user do not follow these printed instructions.; FOR WIRING INSTRUCTIONS AND INSTALLATION OF THE ELEC-; Safety Precautions; Electrocution is possible if you come in contact with a; to a suitable drain.
2 Table of Contents Page CONTRACTOR: How To Install a White-Rodgers ComfortPlus Steam Humidifier ................. Safety Precautions ................................................................................ Tools & Materials Needed ...........................................................
Page 3 - Figure 1; Duct Edge Mount; Figure 2; —Mounting Bracket
4 5 Tools and Materials Needed Safety glasses Tin snips or aviation snips Electric drill /8" and 7/64" drill bits Pliers Screwdrivers (medium flat point and Phillips #1) Level Hammer Small adjustable wrench Center punch Knife Wire and hardware to connect fan control Additional relay(s) For s...
Page 4 - Figure 4; Figure 6; Figure 3; External Side Mount; Figure 5; Duct Center Mount
6 7 Adjust the water level. (See Nos. 7 & 8 in “Plumbing and Setting the Water Level”, pages 8 & 9.) Slide the flanges of the humidifier reservoir into the mounting bracket until the reservoir’s front flange comes in contact with the edge of the duct. Secure the humidifier to the duct with t...
Page 5 - —Saddle Valve and Fittings; never adjust the humidi-; —Raising the
8 9 Plumbing and Setting the Water LevelNOTE: Use copper tubing only to plumb the humidifier. Select the nearest cold water pipe and install the saddle connector and needle valve (provided) by following the instructions supplied with the valve. WARNING: Do not use any line connected to an air condit...
Page 6 - To Install the Flushing Timer on a Steam Humidifier:; Drain tubing must not kink or come in contact with; *The number of seconds will vary depending upon how the unit is; Figure 9; —Installation of a; All plumb
10 11 The Humidifier Automatic Flushing Timer automatically flushes accumulated min - eral deposits from all central-system steam- and reservoir-type humidifiers. This enables homeowners to enjoy the benefits of healthful, humidified air without the hassles of frequent maintenance due to mineral bui...
Page 7 - Do not touch the humidifier when the operation indicator
12 1 Inside, on the circuit board, locate the red switch block which contains two switches, numbered 1 and 2. NOTE: The switches are pre-set in the 10-second mode, with the #1 switch in the ON position and the #2 switch in the OFF position, as shown at right. (Both switches in the ON position will a...
Page 8 - Troubleshooting; Low Humidity; Plumbing and Setting; High Humidity; Plumbing and Setting Water; Table 1; Item; Replacement Parts; Parts may be ordered through your preferred heating or plumb-
14 15 Troubleshooting P ROBLEM E VIDENCE S OLUTIONS Low Humidity Low water level (less See Plumbing and Setting than 2-/8" deep) Water Level , Steps 7 & 8, pgs. 8 & 9 No water in reservoir Turn water on at saddle valve Turn off water main and check for possible obstruction in saddl...
Page 9 - Table 2; How Your Humidifier Works; Plus Steam Humidifier sup-
16 17 Parts for Models HSP2000 and HSP2600 (cont’d.) Item Part Name Part No. 6 Cover 000-0641-150 7* Transformer 120 Volt Primary, 24 Volt Secondary 000-0814-1 7** Transformer 240 Volt Primary, 24 Volt Secondary 000-0814-140 8 Control Relay DPST 24 Volt 000-041-01 9 & 10 Fan Wiring Assembly A00-...
Page 10 - How To Extend the Life of Your Humidifier; Due to the; season, and to contact an HVAC dealer if necessary.; , turn the humidistat and the water supply to the; Programmable; Flushing Timer; voir-type humidifiers; FAQs About IAQ; (Frequently Asked Questions About Indoor Air Quality); Why should I lower my humidistat setting when the outside tempera-; relative humidity
18 19 How To Extend the Life of Your Humidifier Mineral buildup on the humidifier’s heating element is harmful to the unit. Therefore, routine maintenance is vital to the effectiveness and longevity of your humidifier. The normal service interval will vary from one-to-three months (i.e., one or two ...
Page 11 - your local heating and air conditioning contractor:
20 If you have questions about your White-Rodgers ComfortPlus Humidifier, or to learn which White-Rodgers IAQ products are right for your home, contact your local heating and air conditioning contractor: Part No. 000-0756-14 HBP 6/06 8100 W. Florissant Ave. St. Louis, MO 63136-9022 Web: www.white-ro...