Emerson Fisher 480- Manuals

Emerson Fisher 480– Installation Manual in PDF format online.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12

Summary

Page 2 - Instruction Manual

Instruction Manual D100291X012 480 Series Actuators August 2012 2 Table 1. Fisher 480 Series Actuator Specifications Available Configurations See the Actuator Configurations section. Cylinder Pressure Maximum Allowable: (4) 10.3 bar (150 psig) Required to Produce a Given Thrust: See figure 2 Minimum...

Page 4 - Actuator Configurations

Instruction Manual D100291X012 480 Series Actuators August 2012 4 Figure 2. Supply Pressure and Thrusts A5961 NOTE: THRUSTS IN THOUSANDS OF POUNDS (IN THOUSANDS OF NEWTONS) FOR ACTUATORS WITH POSITIONERS MAY BE INCREASED BY 10% FOR ACTUATORS WITHOUT POSITIONERS. EITHER THIS THRUST, OR THE MAXUMUM AL...

Page 5 - Installation; WARNING

Instruction Manual D100291X012 480 Series Actuators August 2012 5 Table 4. Action Under Normal Operating Conditions ACTUATOR DESCRIPTION DESIRED PISTON MOTION Down Up With Positioner Direct-acting Increasing input signal pressure to bellows (1) Decreasing input signal pressure to bellows (1) Reverse...